Filtern
Dokumenttyp
Referierte Publikation
- ja (15) (entfernen)
Schlagworte
- Diagonal compression test (4)
- Earthen materials (4)
- Compression test (3)
- Earth block masonry (2)
- Nosema ceranae (2)
- Numerical modelling (2)
- Osmia bicornis (2)
- Rammed earth (2)
- Uniaxial compression test (2)
- Water repellent admixtures (2)
Organisationseinheit der BAM
The therapy of eye tumors with fast protons is an excellent tool giving very high local control rates. At the Helmholtz-Zentrum Berlin (HZB) almost 1800 patients were treated since 1998. A 2 MV Tandetron was installed as injector for the k = 132 HZB cyclotron. Using the standard 358 duoplasmatron ion source with direct extraction of negative hydrogen ions an extremely stable proton beam can be delivered, both on the short-term and the long-term scale. The hair-needle filaments made from thoriated tungsten wires have safe operation times of more than 1000 h.
Overview of different strengthening techniques applied on walls used in historical structures
(2012)
Characterisation of earthen elements. A comparison between earth block masonry, rammed earth and cob
(2012)
Earth represents one of the oldest construction materials, which is still utilised both in developed and in developing countries. In this paper a comparison of the mechanical performance of structural elements built in three basic techniques, earth block (adobe) masonry, rammed earth and cob, is presented. In order to gain better knowledge on the structural behaviour under static loads an extensive compression and diagonal compression (shear) test campaign was performed. First compression results showed brittle mechanical behaviour in the case of earth block masonry and rammed earth elements, whereas cob exhibited a very different stress–strain pattern: cob can deform beyond the elastic range with a gradual drop in capacity. Despite its low compressive strength, cob thus presents a relatively good performance within the earthen material range as far as shear behaviour is concerned.
The data here reported represents a base for a further investigation on the dynamic behaviour of the three materials considered. The study was carried out within the framework of the project NIKER funded by the European Commission dealing with improving immovable Cultural Heritage assets against the risk of earthquakes.
The study evaluates Portland limestone cement mortars, natural hydraulic lime mortars and pozzolan-lime mortars modified with water-repellent admixtures (metal soaps and siloxanes) for their use in the maintenance of historic buildings. The chemical-physical characteristics, the durability and the resistance to artificial weathering (exposure to UV light and artificial rain) were examined. The exposure conditions used in the ageing test were chosen in order to simulate outdoor environmental conditions, in particular the processes caused by UV-light and thermal shock induced by rain water.
In this paper an extensive research campaign aimed to define the mechanical performance of earth block masonry panels is presented. Uniaxial compression and diagonal compression tests were performed. The test results confirmed the brittle behaviour of earth block masonry under uniaxial compressive load and showed that the failure of earth block masonry under shear load occurs by sliding of the earth blocks along the mortar joints after initial cracking in mortar joints and earth blocks. For diagonal compression test results showed that building technique practice is one of the key factors affecting the structural performances. Experimental behaviour was modelled with a non-linear model capable of describing cracking behaviour. Both micro-modelling and macro-modelling implementing isotropic or orthotropic material laws were used to assess the reliability of different modelling strategies. The model calibration was carried out by sensibility analysis of the input parameters to understand the influence of unit strength on the shear behaviour of masonry.
The paper presents an experimental program aiming at assessing the mechanical performance of rammed earth walls, namely under compression and shear loading. Axial compression and diagonal compression tests were carried out for this purpose, which allowed determining important mechanical parameters, such as compressive strength, Young's modulus, Poisson's ratio, shear strength and shear modulus. Furthermore, it allowed assessing the level of non-linear behaviour of the respective stress–strain relationships as well as the failure modes. The experimental results were then used in the calibration of numerical models (finite element method) for simulating the non-linear behaviour of rammed earth under shear loading. Both macro- and micro modelling approaches were considered for this purpose. The total strain rotating crack model was used to simulate the behaviour of the rammed earth material, while the Mohr–Coulomb failure criterion was used to simulate the behaviour of interfaces between layers. In general, the numerical models achieved good agreement with the experimental results, but uncertainties related to the definition of the input parameters required to perform a sensitivity analysis. The compressive strength, the Poisson's ratio, the tensile strength and the tensile fracture energy revealed to be the most important parameters in the analyses.
The current paper focuses on the determination of reliable numerical models of earth block masonry wallettes under different loading conditions. Uniaxial compression and diagonal compression tests were performed. Experimental behaviour was modelled with a non-linear model able to describe the cracking behaviour. The simplified approach based on macro-modelling shows a satisfactory accuracy and low computational costs. The results reproducing the uniaxial compression are in good correspondence with the post-elastic behaviour observed in the experimental campaign. The micro-modelling approach adopted to reproduce the shear behaviour, even with high computational cost, represents a suitable tool to predict the masonry collapse mechanism.
Water-repellent mortars were prepared using different hydrophobic compounds as admixtures. Calcium and zinc stearates, silane/siloxane products (as liquid solution and powder) were mixed into limestone cement mortars for obtaining in-bulk water-repellent mortars suitable for building protection and resistant to the degrading action of water. The influences of the admixtures on the hydration and structure of the designed mortars were investigated by SEM, TG–DSC, FT-IR, XRD, and isothermal calorimetry. The effectiveness of these agents against water action was evaluated by using techniques and methods such as mercury intrusion porosimetry, water absorption tests and contact angle measurements. Siloxane products conveyed good water-repellent effectiveness, without strongly influencing the setting and hydration of the binder, while the zinc stearates slowed down the hydration reactions.
The purpose of this paper is to numerically simulate the in-plane behaviour of rammed earth walls under cyclic shear-compression tests. The experimental testing allowed obtaining the maximum horizontal loads, the displacement capacity and the level of non-linear behaviour of the respective loaddisplacement relationships as well as the failure modes. The calibration of the numerical model (finite element method) was carried out based on the experimental results. Within this framework, a micromodelling approach was considered. The behaviour of the rammed earth material was simulated using a total strain rotating crack model. A Mohr-Coulomb failure criterion was used to reproduce the behaviour of the interfaces between the layers.
Although the numerical results achieved a satisfactory agreement with the experimental results a sensitivity analysis of the parameters involved was performed. The sensitivity analysis aimed at determining which parameters of the model have a significant impact in the model’s results. As expected the sensitivity analysis pointed out that the sliding failure occurrence is mainly influenced by two parameters of the interface elements: the interface tensile strength fit and the friction angle u. Moreover the cohesion c and the layers thickness showed a limited effect on the shear behaviour. It should be noted that the results mentioned above are related to the cases where a significant level of vertical compressive stress r is employed.