The combination of tomographic, microstructural data with other experimental techniques and with modeling is paramount, if we want to extract the maximum amount of information on material and component properties. In particular, quantitative image analysis, statistical approaches, direct discretization of tomographic reconstructions represent concrete possibilities to extend the power of the tomographic 3D representation to insights into the material and component performance. This logic thread holds equally for industrial and academic research, and valorizes expensive experiments such as those carried out at synchrotron sources, which cannot be daily repeated. We shall show a few examples of possible use of X-ray tomographic data for quantitative assessment of damage evolution and microstructural properties, as well as for non-destructive testing. We will also show how X-ray refraction computed tomography (CT) can be highly complementary to classic absorption CT, being sensitive to internal interfaces.
Bi-continuous porous ceramics for filtration applications possess a particularly complicated microstructure, whereby porosity and solid matter are intermingled. Mechanical, thermal, and filtration properties can only be precisely estimated if the morphology of both solid matter and porosity can be quantitatively determined. Using 3D computed tomography (CT) at different resolutions, and several X-ray refraction-based techniques, we quantitatively evaluated porosity and pore orientation in cordierite diesel particulate filter ceramics.Moreover, applying both Fast Fourier Transform (FFT) and a newly developed image analysis algorithm (directional interface variance analysis, DIVA), we quantitatively evaluated porosity and pore orientation. Both the experimental techniques and the statistical approach allow extraction of spatially resolved or average values.Porosity values from synchrotron computed tomography used turn out to agree with mercury intrusion measurements, while pore orientation factors agree with published crystallographic texture data. This latter point also implies that the study of the pore/matter interface is sufficient to describe the morphological properties of these materials.
For the first time we present direct 2D imaging of refracted X-rays without any discrimination of the Primary radiation. X-refraction works in analogy to visible light optics: X-rays are entirely deflected at interfaces where discontinuities of (electron) density occur. This is demonstrated at the example of inner and outer surfaces of model samples of well-defined geometry (fibres, capillaries, and monodisperse micro particles). The samples are scanned through a 50 μm monochromatic (20 keV) pencil beam. In order to warrant a sufficient angular resolution a 2D detector (pixel size 7 μm) is placed 3 m downstream of the sample. Scanning the sample in micron steps allows for detecting local changes of interface / surface orientation directly in two dimensions. At the actual angular resolution of about 3 seconds of arc (scattering vector increments Δk = 10-3 nm-1) and 50 μm spatial resolution (scanning) the material’s inner surfaces (with nanometer separation) can be characterized even at sampling rates below 1 second per frame. Moreover, our technique is suited to directly determine particle diameters of up to 250 nm by means of diffraction fringes. Some potential applications to technical submicron structures are discussed.
X-ray dark field imaging
(2014)
A new kind of enhanced contrast X-ray imaging of weakly absorbing materials in dark field mode is presented.
Samples such as plastics and biological tissue are a perpetual challenge for radiographic imaging. Recent innovative approaches such as Diffraction Enhanced Imaging (DEI), “phase contrast”, grating interferometry (Talbot-Lau), or Refraction Enhanced Imaging (REI) have in common that they yield enhanced contrast based on deflected X-rays.
Here, we introduce a REI modification, which works with a slightly bent single crystal reflecting in Bragg geometry. The samples are placed upstream of the thin crystal within a parallel synchrotron beam. The crystal’s curvature creates a dark-field stripe in the transmission image, similar to the inverse of a Darwin-Prins rocking curve of plane crystals. The reflection condition is met better or worse as a steady function of incidence position.
Refracted beam portions of sample interfaces appear bright on black stripes. The entire image is finally synthesized by multiple dark-field stripes. The technique is an alternative to the mentioned techniques. We demonstrate the technique’s advantage by examples of biological and technical microstructures.
Die mitunter erhebliche Verschmierung von computertomograpischen Projektionen durch ausgedehnte Strahlenquellen wird durch eine neuartige Entschmierungsprozedur erheblich reduziert, um eine verbesserte Ortsauflösung der Rekonstruktion zu erreichen. Da die Breite der Verschmierungsfunktion der detektornahen und -fernen Objektelemente sich erheblich unterscheiden kann, muss die Entschmierung variabel sein. Im Gegensatz zu einer für alle Voxel-Positionen identischen Entfaltung, also einer grundsätzlich falschen Voraussetzung, wurde eine implizite Entschmierung entwickelt. Die vorab bekannte positionsabhängige Verschmierung wird auf die iterativ wiederholten Projektionen der Teilrekonstruktionen des DIRECTT-Algorithmus angewandt. Die variabel entschmierten Rekonstruktionen aus den Sinogrammen eines Pixelmodells mit Verschmierungen von 1 bis 5 Pixel erreichen eine Ortsauflösung von nahezu einem Pixel.
X-ray computed tomography is an important tool for non-destructively evaluating the 3-D microstructure of modern materials. To resolve material structures in the micrometer range and below, high brilliance synchrotron radiation has to be used. The Federal Institute for Materials Research and Testing (BAM) has built up an imaging setup for micro-tomography and -radiography (BAMline) at the Berliner storage ring for synchrotron radiation (BESSY). In computed tomography, the contrast at interfaces within heterogeneous materials can be strongly amplified by effects related to X-ray refraction. Such effects are especially useful for materials of low absorption or mixed phases showing similar X-ray absorption properties that produce low contrast. The technique is based on ultra-small-angle scattering by microstructural elements causing phase-related effects, such as refraction and total reflection. The extraordinary contrast of inner surfaces is far beyond absorption effects. Crack orientation and fibre/matrix debonding in plastics, polymers, ceramics and metal-matrix-composites after cyclic loading and hydro-thermal aging can be visualized. In most cases, the investigated inner surface and interface structures correlate to mechanical properties. The technique is an alternative to other attempts on raising the spatial resolution of CT machines.
We present an experimental approach to study the three-dimensional microstructure of gas diffusion layer (GDL) materials under realistic compression conditions. A dedicated compression device was designed that allows for synchrotron-tomographic investigation of circular samples under well-defined compression conditions. The tomographic data provide the experimental basis for stochastic modeling of nonwoven GDL materials. A plain compression tool is used to study the fiber courses in the material at different compression stages. Transport relevant geometrical parameters, such as porosity, pore size, and tortuosity distributions, are exemplarily evaluated for a GDL sample in the uncompressed state and for a compression of 30 vol.%. To mimic the geometry of the flow-field, we employed a compression punch with an integrated channel-rib-profile. It turned out that the GDL material is homogeneously compressed under the ribs, however, much less compressed underneath the channel. GDL fibers extend far into the channel volume where they might interfere with the convective gas transport and the removal of liquid water from the cell.
High-density polyethylene becomes optically transparent during tensile drawing when previously saturated with diesel fuel. This unusual phenomenon is investigated as it might allow conclusions with respect to the material behavior. Microscopy, differential scanning calorimetry, density measurements are applied together with two scanning X-ray scattering techniques: wide angle X-ray scattering (WAXS) and X-ray refraction, able to extract the spatially resolved crystal orientation and internal surface, respectively. The sorbed diesel softens the material and significantly alters the yielding characteristics. Although the crystallinity among stretched regions is similar, a virgin reference sample exhibits strain whitening during stretching, while the diesel-saturated sample becomes transparent. The WAXS results reveal a pronounced fiber texture in the tensile direction in the stretched region and an isotropic orientation in the unstretched region. This texture implies the formation of fibrils in the stretched region, while spherulites remain intact in the unstretched parts of the specimens. X-ray refraction reveals a preferred orientation of internal surfaces along the tensile direction in the stretched region of virgin samples, while the sample stretched in the diesel-saturated state shows no internal surfaces at all. Besides from stretching saturated samples, optical transparency is also obtained from sorbing samples in diesel after stretching.
The performance of grating interferometers coming up now for Imaging interfaces within materials depends on the efficiency (visibility) of their main component, namely the phase grating. Therefore, experiments with monochromatic synchrotron radiation and corresponding simulations are carried out. The visibility of a Phase grating is optimized by different photon energies, varying detector to grating distances and continuous rotation of the phase grating about the grid lines. Such kind of rotation changes the projected grating shapes, and thereby the distribution profiles of phase shifts. This yields higher visibilities than derived from ideal rectangular shapes. By continuous grating rotation and variation of the propagation distance, we achieve 2D visibility maps. Such maps provide the visibility for a certain combination of grating orientation and detector position. Optimum visibilities occur at considerably smaller distances than in the standard setup.
In order to investigate their microcracking behaviour, the microstructures of several β-eucryptite ceramics, obtained from glass precursor and cerammed to yield different grain sizes and microcrack densities, were characterized by laboratory and synchrotron x-ray refraction and tomography. Results were compared with those obtained from scanning electron microscopy (SEM). In SEM images, the characterized materials appeared fully dense but computed tomography showed the presence of pore clusters. Uniaxial tensile testing was performed on specimens while strain maps were recorded and analyzed by Digital Image Correlation (DIC). X-ray refraction techniques were applied on specimens before and after tensile testing to measure the amount of the internal specific surface (i.e., area per unit volume). X-ray refraction revealed that (a) the small grain size (SGS) material contained a large specific surface, originating from the grain boundaries and the interfaces of TiO2 precipitates; (b) the medium (MGS) and large grain size (LGS) materials possessed higher amounts of specific surface compared to SGS material due to microcracks, which decreased after tensile loading; (c) the precursor glass had negligible internal surface. The unexpected decrease in the internal surface of MGS and LGS after tensile testing is explained by the presence of compressive regions in the DIC strain maps and further by theoretical arguments. It is suggested that while some microcracks merge via propagation, more close mechanically, thereby explaining the observed X-ray refraction results. The mechanisms proposed would allow the development of a strain hardening route in ceramics.