Filtern
Erscheinungsjahr
Dokumenttyp
- Zeitschriftenartikel (27)
- Beitrag zu einem Tagungsband (21)
- Beitrag zu einem Sammelband (17)
- Sonstiges (7)
- Buchkapitel (2)
- Posterpräsentation (1)
Schlagworte
- X-ray refraction (17)
- Computed tomography (12)
- Synchrotron radiation (5)
- Computed Tomography (4)
- Diffuse background (4)
- Fluorescent screen (4)
- Keramik (4)
- Phase contrast (4)
- Refraction (4)
- Röntgenrefraktion (4)
Organisationseinheit der BAM
Analyser-based imaging expands the performance of X-ray imaging by utilizing not only the absorption properties of X-rays but also the refraction and scatter rejection (extinction) properties. In this study, analyser-based computed tomography has been implemented on imaging an articular cartilage sample, depicting substructural variations, without overlay, at a pixel resolution of 3.6 µm.
Erstmals wurden MMCs mit Hilfe der Interface-Kontrast verstärkenden Röntgen-Refraktions-Technik in Kombination mit der 3D-CT-Technik untersucht. Die Methode der Röntgen-Refraktions-Topography sowie der Röntgen-Refraktions-Tomography wurden in den letzten Jahren speziell für die zerstörungsfreie Charakterisierung von Leichtbau-Hochleistungs-Werkstoffen wie Verbund-Werkstoffen und Keramiken entwickelt. Die Technik basiert auf der Refraktion von Röntgenlicht an Grenzflächen zwischen Bereichen unterschiedlicher Elektronendichte wie z.B. Faser- und Matrix-Werkstoff. Auf Grund der kurzen Röntgen-Wellenlänge hat der Brechungsindex einen Wert dicht bei eins, sodass der Streuwinkel nur wenige Bogenminuten beträgt. Der Vorteil der kurzen Wellenlänge besteht jedoch darin, dass Poren und Risse detektiert werden können, deren Größe im Nanometerbereich liegen. Damit kann die Refraktions-Technik zum besseren Verständnis von Mikro- und Submikro-Strukturen in der Materialwissenschaft eingesetzt werden. Mit der hier vorgestellten Refraktions-CT wurden Ermüdungsmechanismen an MMCs, bestehend aus SiC-Faser verstärktem Titan (Ti6242) untersucht. Die Messungen wurden am Röntgen-Messplatz der BAM (BAMline) am Synchrotron-Speicherring-BESSY in Berlin Adlershof durchgeführt.
Microstructural aspects of composites such as reinforcement particle size, shape, and distribution play important roles in deformation behavior. In addition, Fe-rich inclusions and porosity also influence the behavior of these composites, particularly under fatigue loading. Three-dimensional (3-D) visualization of porosity and Fe-rich inclusions in three dimensions is critical to a thorough understanding of fatigue resistance of metal matrix composites (MMCs), because cracks often initiate at these defects. In this article, we have used X-ray synchrotron tomography to visualize and quantify the morphology and size distribution of pores and Fe-rich inclusions in a SiC particle-reinforced 2080 Al alloy composite. The 3-D data sets were also used to predict and understand the influence of defects on the deformation behavior by 3-D finite element modeling.
Synchrotron-Refraktions-Computer-Tomographie - EIne neue Methode zur Erkennung von Grenzflächen
(2009)
Rekonstruktion unvollständiger computertomografischer Modelldatensätze mit Directt-Algorithmus
(2010)
Modellrechnungen zur Rekonstruktion unvollständiger computertomographischer Datensätze werden zur Ermittlung der Vorteile des neuen Directt-Algorithmus gegenüber der konventionellen gefilterten Rückprojektion durchgeführt, insbesondere auch zur Vermeidung experimentell begründeter Unwägbarkeiten. Ein entsprechender Bedarf entsteht seitens erweiterter Forschungsaktivitäten und industrieller Bedürfnisse, wo die Rekonstruktion limitierter Messdatensätze von Artefakten dominiert wird. Die bekanntesten Einschränkungen betreffen das Limited-View- und Few-Angles-Problem sowie die ROI-Situation, die jeweils unabhängig voneinander untersucht werden, in der Anwendung jedoch zumeist undefiniert vermischt sind, wie etwa in der Elektronen-Tomografie. Die hochauflösende Rekonstruktion von Einzelpixeln wird durch die Wahl eines kleinen Modells von nur 1012 Pixeln visualisiert und ist ohne Filterung möglich. Rekonstruktionen von 90°-Sektoren oder 50 % -ROI-Querschnitten sind fast ohne Auflösungseinschränkungen realisierbar. Die bisher nicht bekannte Möglichkeit, auch außerhalb der ROI präzise zu rekonstruieren, wurde als "Extended ROI"-Methode erfolgreich erprobt.
A novel approach to strongly suppress artifacts in radiography and computed tomography caused by the effect of
diffuse background signals ('backlighting') of 2D X-ray detectors is suggested. Depending on the detector
geometry the mechanism may be different, either based on the optical scattering of the fluorescent screen
materials into optical detection devices or Compton or X-ray fluorescence scattering by the detector components.
Consequently, these erroneous intensity portions result in locally different violations of Lambert Beers law in
single projections (radiographs) as function of the detector area coverage and the magnitude of the attenuation.
The absorption of multiple metal sheets is investigated by monochromatic synchrotron radiation, thus excluding
beam hardening. The proposed correction procedure simply requires the individual subtraction of one and the
same fraction of the primary and transmitted mean intensity, as a constant (non-local) scattering mechanism is
assumed.
The relevance of nano sized structures and interfaces in upcoming technologies requires new non-destructive Xray
techniques exploiting attenuation as well as scattering. In the course of driving the resolution and the contrast
of modern radiography into micro and nano metre dimension the inevitable scattering effects require increased
attention. Several radiologists interpret the observed edge artefacts simply by 'phase contrast' due to different
X-ray path lengths within the sample and others refer to Fresnel scattering. The ultra small angle scattering is of
high intensity and may reach the level of the primary beam. We present monochromatic synchrotron
measurements on rather simply shaped objects (such as plates and cylinders) which prove clearly the dominance
of refraction intensity over total reflection and coherent small angle scattering. The refraction conditions hold for
angles of incidence of several degrees to the surface, but typical deflection angles range from several seconds to
minutes of arc. Additionally to the concept of 'phase contrast' of the primary beam its deflection becomes the
essential issue. The appropriate removal of the attenuation contribution enables the imaging of inner surfaces and
interfaces by refraction scanning topography. The presented measurements of reference particles demonstrate the
reliability of laboratory refraction scanners applying X-ray tubes.
Evaluating porosity in cordierite diesel particulate filter materials, part 1 X-ray refraction
(2013)
Bi-continuous porous ceramics for filtration applications possess a particularly complicated microstructure, with porosity and solid matter being intermingled. Mechanical, thermal, and filtration properties can only be precisely estimated if the morphology of both solid matter and porosity can be quantitatively determined. Using x-ray absorption and refraction, we quantitatively evaluate porosity and pore orientation in cordierite diesel particulate filter ceramics. Porosity values turn out to agree with mercury intrusion measurements, while pore orientation factors agree with published crystallographic texture data.
We present a synchrotron X-ray tomographic study on the morphology of carbon fiber-based gas diffusion layer (GDL) material under compression. A dedicated compression device is used to provide well-defined compression conditions. A flat compression punch is employed to study the fiber geometry at different degrees of compression. Transport relevant geometrical parameters such as porosity, pore size and tortuosity distributions are calculated. The geometric properties notably change upon compression which has direct impact on transport conditions for gas and fluid flow. The availability of broad 3D paths, which are most important for the transport of liquid water from the catalyst layer through the GDL, is markedly reduced after compression. In a second experiment, we study the influence of the channel-land-pattern of the flow-field on shape and microstructure of the GDL. A flow-field compression punch is employed to reproduce the inhomogeneous compression conditions found during fuel cell assembly. While homogenously compressed underneath the land the GDL is much less and inhomogeneously compressed under the channel. The GDL material extends far into the channel volume where it can considerably influence gas and fluid flow. Loose fiber endings penetrate deeply into the channel and form obstacles for the discharge of liquid water droplets.
Complementary to Part 1 of this work, the bi-continuous microstructure of porous synthetic cordierite ceramics for filtration applications was investigated using 3D x-ray computed tomography at different resolutions. Applying both Fast Fourier Transform and a newly developed image analysis algorithm, we quantitatively evaluated porosity and pore orientation. The statistical approach allows extraction of spatially resolved or average values. Porosity values based on x-ray absorption agree with mercury intrusion measurements, while pore orientation factors agree with x-ray refraction data (Part 1 of this work), and with published crystallographic texture data.
Anhand von computertomografischen Messungen und Modellrechnungen werden DIRECTT-Rekonstruktionen im Vergleich mit gefilterten Rückprojektionen bewertet. Dazu wird die Rekonstruktionsqualität mittels einer zirkular erweiterten Modulations-Transfer-Funktion (MTF) und mit integralen Kenngrößen im Radon- und im Ortsraum verglichen. Zur Überprüfung der Rekonstruktionsgenauigkeit experimenteller Daten werden Mustermessungen einfacher Probengeometrien unter definierten physikalischen Bedingungen durchgeführt. Diese beinhalten die Monochromasie, die Unterdrückung von Kantenartefakten und die radiometrische Intensitätsbestimmung. Für die Qualität der Rekonstruktionen mittels DIRECTT erweisen sich sowohl unterschiedliche Rekonstruktionsfilter als auch der Verzicht auf jede Filterung als unerheblich, im Gegensatz zur gefilterten Rückprojektion.
The combination of tomographic, microstructural data with other experimental techniques and with modeling is paramount, if we want to extract the maximum amount of information on material and component properties. In particular, quantitative image analysis, statistical approaches, direct discretization of tomographic reconstructions represent concrete possibilities to extend the power of the tomographic 3D representation to insights into the material and component performance. This logic thread holds equally for industrial and academic research, and valorizes expensive experiments such as those carried out at synchrotron sources, which cannot be daily repeated. We shall show a few examples of possible use of X-ray tomographic data for quantitative assessment of damage evolution and microstructural properties, as well as for non-destructive testing. We will also show how X-ray refraction computed tomography (CT) can be highly complementary to classic absorption CT, being sensitive to internal interfaces.