Filtern
Erscheinungsjahr
Dokumenttyp
- Zeitschriftenartikel (60)
- Vortrag (19)
- Beitrag zu einem Tagungsband (18)
- Beitrag zu einem Sammelband (15)
- Sonstiges (8)
- Posterpräsentation (6)
- Buchkapitel (1)
Sprache
- Englisch (127) (entfernen)
Schlagworte
- X-ray refraction (41)
- Computed tomography (17)
- Synchrotron radiation (11)
- Computed Tomography (7)
- Refraction (7)
- Synchrotron (7)
- BAMline (6)
- Metal matrix composites (6)
- Additive manufacturing (5)
- Composites (5)
Organisationseinheit der BAM
- 8 Zerstörungsfreie Prüfung (38)
- 8.5 Röntgenbildgebung (38)
- 5 Werkstofftechnik (3)
- 5.3 Polymere Verbundwerkstoffe (2)
- 6 Materialchemie (2)
- 5.4 Multimateriale Fertigungsprozesse (1)
- 6.1 Oberflächen- und Dünnschichtanalyse (1)
- 6.3 Strukturanalytik (1)
- 7 Bauwerkssicherheit (1)
- 7.5 Technische Eigenschaften von Polymerwerkstoffen (1)
Paper des Monats
- ja (1)
Eingeladener Vortrag
- nein (19)
Non-destructive evaluation of advanced materials by synchrotron radiation refraction topography
(2002)
The first hard X-ray beamline at BESSY II will be installed by BAM and PTB at a superconducting 7 T wavelength shifter. The main optical elements of the beamline are a Double-Multilayer-Monochromator and a Double-Crystal-Monochromator. The two devices can be used separately or in-line. Main applications of monochromatic radiation with photon energies up to 50 keV are X-ray fluorescence analysis, micro-computed tomography, X-ray topography, detector calibration and reflectometry. Calculable undispersed radiation up to 200 keV will be available for radiometric applications.
For the first time Metal Matrix Composites (MMC) have been investigated by 3D Computed Tomography combined with enhanced interface contrast due to X-ray refraction. X-ray refraction is a relatively new approach for the characterization of advanced materials. The related techniques of Refraction Topography and Refraction Computed Tomography have been developed and applied at our laboratory during the last decade to meet the actual demand for improved nondestructive characterization of high performance composites, ceramics and other low density materials and components. X-ray refraction occurs, when X-rays crosses interfaces of spherical or cylindrical shape (e.g. pores or fibres) in the same way as visible light is refracted by lenses. These X-ray optical effects can be observed at small scattering angles of few minutes of arc as the refractive index n of X-rays is nearly unity (n = 1 10-6). Due to the short X-ray wavelength of about 0.1 nm the technique determines the amount of inner surfaces and interfaces of nanometer dimensions. The technique is expected to solve many problems in understanding the meaning of micro and sub micro structures in materials science. With the results of the CT investigation, some questions could be clarified for a better understanding of fatigue failure mechanisms under cyclic loading conditions. The specimens for the test programme have been provided by MTU Aero Engines. They consist of a titanium matrix (Ti6242) reinforced by SiC fibres (SCS6). The investigations have been performed at the materials research station of BAM (BAMline) at the Synchrotron Facility BESSY in Berlin, Germany.
The first hard x-ray beamline at BESSY II has been installed by BAM and PTB at a superconducting 7 T wavelength shifter. The main optical elements of the beamline are a double-multilayer monochromator and a double-crystal monochromator. Depending on the application, the two devices are used separately or in-line. The main applications of the monochromatic radiation with photon energies up to 60 keV are x-ray fluorescence analysis, micro computed tomography, x-ray topography, detector calibration and reflectometry. Calculable undispersed radiation up to 200 keV is available for radiometric applications.
The employment of synchrotron radiation for refraction topography of materials has considerable advantages over standard x-ray sources. The much higher beam intensity and the parallel and monochromatic radiation provide faster measurements and better angular and spatial resolution. X-ray refraction techniques image the inner surface and interface concentration of micro-structured materials. This effect of x-ray optics is additional to small-angle scattering by diffraction, when the scattering objects reach micrometre dimensions. We have developed x-ray refraction techniques within the last decade in order to meet the growing demands for improved non-destructive characterization of high-performance composites, ceramics and other low-density materials. Sub-micron particle dimensions, the pore size of ceramics, the crack density distribution and single fibre debonding within damaged composites can be measured and visualized by computer-generated interface topographs. For this purpose investigations are now being performed at the new hard x-ray beamline of the Federal Institute for Materials Research and Testing (BAM) at BESSY, Berlin. This BAMline provides monochromatic radiation of photon energies from 5 to 60 keV from a double multilayer and/or a double-crystal monochromator. A separate instrument is dedicated to the further development and application of synchrotron radiation refraction (SRR) topography. Different from conventional small-angle scattering cameras with collimating slits and pinholes, scattering angles down to a few seconds of arc are selected by a single-crystal analyser, similar to a Bonse-Hart diffractometer. A 20 µm spatial resolution of the scattering micro-structures is achieved by a CCD camera with a fluorescent converter. First SRR topographs of aircraft composites [carbon fibre-reinforced plastics (CFRP), carbon fibre-reinforced ceramics (C/C), metal matrix ceramics (MMC)] will be reported.
X-Ray Refraction Topography
(2004)
A novel approach is suggested to strongly suppress artifacts in radiography and computed tomography caused by the effect of diffuse background signals 'backlighting' of 2D X-ray detectors. Depending on the detector geometry the mechanism may be different. Either based on the optical scattering of the fluorescent screen materials into the optical detection devices or Compton or X-ray fluorescence scattering by the detector components. Consequently, these erroneous intensity portions result in locally different violations of Lambert Beer's law in single projections (radiographs) as a function of the detector area coverage and the magnitude of the attenuation. The absorption of multiple metal sheets is investigated by monochromatic synchrotron radiation, thus excluding beam hardening. The proposed correction procedure simply requires the individual subtraction of one and the same fraction of the primary and transmitted mean intensity, as a constant (non-local) scattering mechanism is assumed.
We investigated to our knowledge for the first time the capabilities of long period gratings (LPG) in single-mode microstructured polymer optical fibre (mPOF) as real-time gamma dosimeter. The fibre is made from polymethyl methacrylate (PMMA) with a polycarbonate jacket. We measured the radiation-induced wavelength shift of the mPOF LPG loss feature wavelength and the radiation-induced attenuation of a mPOF for
different wavelength between 600 nm and 800 nm for gamma radiation with an energy distribution between 6 keV and 18 keV.
A novel approach to strongly suppress artifacts in radiography and computed tomography caused by the effect of diffuse background Signals (backlight) of 2D X-ray detectors is suggested. Depending on the detector geometry the mechanism may be different, either based on the optical scattering of the fluorescent screen materials into optical detection devices or Compton or X-ray fluorescence scattering by the detector components. Consequently, these erroneous intensity portions result in locally different violations of Lambert Beers law in single projections (radiographs).
When used as input data for computed tomography these violations are directly observed via modulation of the projected mass as a function of the rotation Phase and the samples aspect ratio (dynamics). The magnitude of the diffuse Background signal depends on the detector area covered by the projected sample. They are more pronounced the smaller the shaded area and the stronger the total attenuation.
Moreover, the local intensity mismatch depends on the attenuation of the sample.
We present very basic reference data measured with multiple metal foils at a synchrotron radiation source. Beam hardening artifacts can be excluded due to the monochromatic radiation. The proposed correction procedure assumes a constant (non-local) scattering mechanism.
Beyond classical X-ray techniques are used for the purpose of preferably short-term applications, but some supplementary X-ray and synchrotron techniques for higher resolution microdiagnostics take advantage of scattering effects. In contrast to directly imaging methods their resolution is only limited by the diffraction limit of the X-ray wavelength, far below the atomic dimensions. These techniques of scanning topography and refraction synchrotron tomography may permit the systematic diagnostics for finding and exploiting structure/property relations like correlations among atomic, nano and microstructures with macroscopic properties. Their basic advantage over microscopic techniques is their potential for the non-destructive characterisation of materials, far from invasive sample treatments. They combine scattering and spatial resolution.
A novel approach to strongly suppress artifacts in radiography and computed tomography caused by the effect of diffuse background signals ('backlighting') of 2D X-ray detectors is suggested. Depending on the detector geometry the mechanism may be different, either based on the optical scattering by the fluorescent screen materials into optical detection devices or Compton or X-ray fluorescence scattering by the detector components. Consequently, these erroneous intensity portions result in locally different violations of Lambert–Beer's law in single projections (radiographs). When used as input data for computed tomography these violations are directly observed via modulation of the projected mass as a function of the rotation phase and the samples aspect ratio (dynamics). The magnitude of the diffuse background signal depends on the detector area covered by the projected sample. They are more pronounced the smaller the shadowed area and the stronger the total attenuation. This implies that the reconstruction suffers from additional anisotropic artifacts caused by elongated sample structures. This issue is studied simply by absorption of flat plates in a conventional laboratory radiography set-up and at a synchrotron radiation facility. In the latter case beam hardening artifacts can be excluded due to the monochromatic radiation. The proposed correction procedure requires simple integral intensity offsets as a constant (non-local) light scattering mechanism is assumed.
Synchrotron X-ray radiography and tomography investigations of a custom-made polymer electrolyte membrane fuel cell optimised for visualisation purposes are presented. The 3D water distribution and transport pathways in the porous carbon fibre gas diffusion layers (GDLs) were investigated. The authors found that water is not only moving from the GDL into the channel, but can also take the opposite way, that is, from the channel into free pore space of the GDL. Such movement of water into the opposite direction has been subject of speculations but has so far not yet been reported and might bring new insights into the general water transport behaviour, which might give new aspects to the general description of water transport processes and influence modelling assumptions to describe the process taking place in the GDL.
The high-resolution synchrotron-based imaging stations at the BAMline (BESSY) and TopoTomo (ANKA)
(2008)
The BAMline at the BESSY light source in Berlin and the TopoTomo beamline at the ANKA synchrotron facility in Karlsruhe (both Germany) operate in the hard X-ray regime (above 6 keV) with similiar photon flux density. For typical imaging applications, a double multilayer monochromator or a filtered white beam is used. In order to optimise the field of view and the resolution of the available indirect pixel detectors, different optical systems have been installed, adapted, respectively, to a large field of view (macroscope) and to high spatial resolution (microscope). They can be combined with different camera systems, ranging from 16-bit dynamic range slow-scan CCDs to fast CMOS cameras. The spatial resolution can be brought substantially beyond the micrometer limit by using a Bragg magnifier. The moderate flux of both beamlines compared to other 3rd generation light sources is compensated by a dedicated scintillator concept. For selected applications, X-ray beam collimation has proven to be a reliable approach to increase the available photon flux density. Absorption contrast, phase contrast, holotomography and refraction-enhanced imaging are used depending on the application. Additionally, at the TopoTomo beamline digital white beam synchrotron topography is performed, using the digital X-ray pixel detectors installed.
The use of high brilliance and partial coherent synchrotron light for radiography and computed tomography (CT) allows to image micro-structured, multi-component specimens with different contrast modes and resolutions up to submicrometer range. This is of high interest for materials research, life science and non-destructive evaluation applications. An imaging setup for microtomography and radiography installed at BESSY II (a third generation synchrotron light source located in Berlin, Germany) as part of its first hard X-ray beamline (BAMline) can now be used for absorption, refraction as well as phase contrast dedicated to inhouse research and applications by external users. Monochromatic synchrotron light between 6 keV and 80 keV is attained via a fully automated double multilayer monochromator. For imaging applications the synchrotron beam transmitted by the sample is converted with a scintillator into visible light. By use of microscope optics this luminescence image is then projected onto, e.g., a CCD chip. Several scintillating materials are used in order to optimise the performance of the detector system. Different optical systems are available for imaging ranging from a larger field of view and moderate resolutions (macroscope up to 14 mm x 14 mm field of view) to high resolution (microscope down to 0.35 μm pixel size), offering magnifications from 1.8× to 40×. Additionally asymmetric cut Bragg crystals in front of the scintillator can be used for a further magnification in one dimension by a factor of about 20. Slow and fast cameras are available, with up to 16 bit dynamic range. We show the suitability of the setup for numerous applications from materials research and life science.
X-ray refraction topography techniques are based on ultra-small angle scattering by micro-structural elements causing phase-related effects such as refraction and total reflection at a few minutes of arc as the refractive index of X-rays is nearly unity. The refraction contrast is several times higher than true absorption and results in images of cracks, pores and fibre debonding separations below the spatial resolution of the detector. In most cases the investigated inner surface and interface structures correlate to mechanical properties. For the exploration of micro structured materials the refraction technique has been improved by a 3D Synchrotron Refraction Computed Tomography test station. The specimen is placed in an X-ray beam between two single crystals, which suppresses all sample scattering. In addition, an asymmetric cut second crystal can magnify the image up to 50 times revealing nano meter resolution. The technique is an alternative to other attempts on raising the spatial resolution of CT machines.
Analyser-based imaging expands the performance of X-ray imaging by utilizing not only the absorption properties of X-rays but also the refraction and scatter rejection (extinction) properties. In this study, analyser-based computed tomography has been implemented on imaging an articular cartilage sample, depicting substructural variations, without overlay, at a pixel resolution of 3.6 µm.
Erstmals wurden MMCs mit Hilfe der Interface-Kontrast verstärkenden Röntgen-Refraktions-Technik in Kombination mit der 3D-CT-Technik untersucht. Die Methode der Röntgen-Refraktions-Topography sowie der Röntgen-Refraktions-Tomography wurden in den letzten Jahren speziell für die zerstörungsfreie Charakterisierung von Leichtbau-Hochleistungs-Werkstoffen wie Verbund-Werkstoffen und Keramiken entwickelt. Die Technik basiert auf der Refraktion von Röntgenlicht an Grenzflächen zwischen Bereichen unterschiedlicher Elektronendichte wie z.B. Faser- und Matrix-Werkstoff. Auf Grund der kurzen Röntgen-Wellenlänge hat der Brechungsindex einen Wert dicht bei eins, sodass der Streuwinkel nur wenige Bogenminuten beträgt. Der Vorteil der kurzen Wellenlänge besteht jedoch darin, dass Poren und Risse detektiert werden können, deren Größe im Nanometerbereich liegen. Damit kann die Refraktions-Technik zum besseren Verständnis von Mikro- und Submikro-Strukturen in der Materialwissenschaft eingesetzt werden. Mit der hier vorgestellten Refraktions-CT wurden Ermüdungsmechanismen an MMCs, bestehend aus SiC-Faser verstärktem Titan (Ti6242) untersucht. Die Messungen wurden am Röntgen-Messplatz der BAM (BAMline) am Synchrotron-Speicherring-BESSY in Berlin Adlershof durchgeführt.