For the first time Metal Matrix Composites (MMC) have been investigated by 3D Computed Tomography combined with enhanced interface contrast due to X-ray refraction. X-ray refraction is a relatively new approach for the characterization of advanced materials. The related techniques of Refraction Topography and Refraction Computed Tomography have been developed and applied at our laboratory during the last decade to meet the actual demand for improved nondestructive characterization of high performance composites, ceramics and other low density materials and components. X-ray refraction occurs, when X-rays crosses interfaces of spherical or cylindrical shape (e.g. pores or fibres) in the same way as visible light is refracted by lenses. These X-ray optical effects can be observed at small scattering angles of few minutes of arc as the refractive index n of X-rays is nearly unity (n = 1 10-6). Due to the short X-ray wavelength of about 0.1 nm the technique determines the amount of inner surfaces and interfaces of nanometer dimensions. The technique is expected to solve many problems in understanding the meaning of micro and sub micro structures in materials science. With the results of the CT investigation, some questions could be clarified for a better understanding of fatigue failure mechanisms under cyclic loading conditions. The specimens for the test programme have been provided by MTU Aero Engines. They consist of a titanium matrix (Ti6242) reinforced by SiC fibres (SCS6). The investigations have been performed at the materials research station of BAM (BAMline) at the Synchrotron Facility BESSY in Berlin, Germany.
A novel approach is suggested to strongly suppress artifacts in radiography and computed tomography caused by the effect of diffuse background signals 'backlighting' of 2D X-ray detectors. Depending on the detector geometry the mechanism may be different. Either based on the optical scattering of the fluorescent screen materials into the optical detection devices or Compton or X-ray fluorescence scattering by the detector components. Consequently, these erroneous intensity portions result in locally different violations of Lambert Beer's law in single projections (radiographs) as a function of the detector area coverage and the magnitude of the attenuation. The absorption of multiple metal sheets is investigated by monochromatic synchrotron radiation, thus excluding beam hardening. The proposed correction procedure simply requires the individual subtraction of one and the same fraction of the primary and transmitted mean intensity, as a constant (non-local) scattering mechanism is assumed.
We present an experimental approach to study the three-dimensional microstructure of gas diffusion layer (GDL) materials under realistic compression conditions. A dedicated compression device was designed that allows for synchrotron-tomographic investigation of circular samples under well-defined compression conditions. The tomographic data provide the experimental basis for stochastic modeling of nonwoven GDL materials. A plain compression tool is used to study the fiber courses in the material at different compression stages. Transport relevant geometrical parameters, such as porosity, pore size, and tortuosity distributions, are exemplarily evaluated for a GDL sample in the uncompressed state and for a compression of 30 vol.%. To mimic the geometry of the flow-field, we employed a compression punch with an integrated channel-rib-profile. It turned out that the GDL material is homogeneously compressed under the ribs, however, much less compressed underneath the channel. GDL fibers extend far into the channel volume where they might interfere with the convective gas transport and the removal of liquid water from the cell.
Analyser-based imaging expands the performance of X-ray imaging by utilizing not only the absorption properties of X-rays but also the refraction and scatter rejection (extinction) properties. In this study, analyser-based computed tomography has been implemented on imaging an articular cartilage sample, depicting substructural variations, without overlay, at a pixel resolution of 3.6 µm.
The first hard X-ray beamline at BESSY II will be installed by BAM and PTB at a superconducting 7 T wavelength shifter. The main optical elements of the beamline are a Double-Multilayer-Monochromator and a Double-Crystal-Monochromator. The two devices can be used separately or in-line. Main applications of monochromatic radiation with photon energies up to 50 keV are X-ray fluorescence analysis, micro-computed tomography, X-ray topography, detector calibration and reflectometry. Calculable undispersed radiation up to 200 keV will be available for radiometric applications.
Bikontinuierliche poröse Keramiken für Filteranwendungen weisen eine komplizierte Mikrostruktur auf, in der Poren und Festkörperphase 'vermischt' sind. Mechanische, thermische sowie Filtereigenschaften können nur präzise bestimmt werden, wenn die Morphologie beider Phasen quantitativ angegeben werden kann. Hier werden unter Anwendung von 3D Computertomographie (CT) und verschiedenen Techniken, die auf der Röntgenrefraktion basieren, die Porosität und die Porenorientierung in keramischen Cordierit-Dieselpartikelfiltern bewertet. Dabei werden zur Auswertung der Tomogramme die Fouriertransformierten sowie eine neu entwickelte richtungssensitive Bildanalyse (DIVA, directional interface variance analysis) angewandt. Sowohl die genannten Messtechniken als auch der statistische Ansatz gestatten die Extraktion optional ortsaufgelöster oder gemittelter Werte. Es ergeben sich sehr gute Übereinstimmungen der experimentell ermittelten Porositätswerte mit Ergebnissen aus Quecksilberintrusionsversuchen als auch der ermittelten Porenorientierung im Vergleich zu publizierten Angaben zur kristallographischen Textur. Dies legt den Schluss nahe, dass die Kenntnis der Grenzflächen (zwischen Poren und Materie) genügt, die morphologischen Eigenschaften solcher Materialien hinreichend zu beschreiben.
A novel approach to strongly suppress artifacts in radiography and computed tomography caused by the effect of diffuse background Signals (backlight) of 2D X-ray detectors is suggested. Depending on the detector geometry the mechanism may be different, either based on the optical scattering of the fluorescent screen materials into optical detection devices or Compton or X-ray fluorescence scattering by the detector components. Consequently, these erroneous intensity portions result in locally different violations of Lambert Beers law in single projections (radiographs).
When used as input data for computed tomography these violations are directly observed via modulation of the projected mass as a function of the rotation Phase and the samples aspect ratio (dynamics). The magnitude of the diffuse Background signal depends on the detector area covered by the projected sample. They are more pronounced the smaller the shaded area and the stronger the total attenuation.
Moreover, the local intensity mismatch depends on the attenuation of the sample.
We present very basic reference data measured with multiple metal foils at a synchrotron radiation source. Beam hardening artifacts can be excluded due to the monochromatic radiation. The proposed correction procedure assumes a constant (non-local) scattering mechanism.
High-density polyethylene becomes optically transparent during tensile drawing when previously saturated with diesel fuel. This unusual phenomenon is investigated as it might allow conclusions with respect to the material behavior. Microscopy, differential scanning calorimetry, density measurements are applied together with two scanning X-ray scattering techniques: wide angle X-ray scattering (WAXS) and X-ray refraction, able to extract the spatially resolved crystal orientation and internal surface, respectively. The sorbed diesel softens the material and significantly alters the yielding characteristics. Although the crystallinity among stretched regions is similar, a virgin reference sample exhibits strain whitening during stretching, while the diesel-saturated sample becomes transparent. The WAXS results reveal a pronounced fiber texture in the tensile direction in the stretched region and an isotropic orientation in the unstretched region. This texture implies the formation of fibrils in the stretched region, while spherulites remain intact in the unstretched parts of the specimens. X-ray refraction reveals a preferred orientation of internal surfaces along the tensile direction in the stretched region of virgin samples, while the sample stretched in the diesel-saturated state shows no internal surfaces at all. Besides from stretching saturated samples, optical transparency is also obtained from sorbing samples in diesel after stretching.
For the first time we present direct 2D imaging of refracted X-rays without any discrimination of the Primary radiation. X-refraction works in analogy to visible light optics: X-rays are entirely deflected at interfaces where discontinuities of (electron) density occur. This is demonstrated at the example of inner and outer surfaces of model samples of well-defined geometry (fibres, capillaries, and monodisperse micro particles). The samples are scanned through a 50 μm monochromatic (20 keV) pencil beam. In order to warrant a sufficient angular resolution a 2D detector (pixel size 7 μm) is placed 3 m downstream of the sample. Scanning the sample in micron steps allows for detecting local changes of interface / surface orientation directly in two dimensions. At the actual angular resolution of about 3 seconds of arc (scattering vector increments Δk = 10-3 nm-1) and 50 μm spatial resolution (scanning) the material’s inner surfaces (with nanometer separation) can be characterized even at sampling rates below 1 second per frame. Moreover, our technique is suited to directly determine particle diameters of up to 250 nm by means of diffraction fringes. Some potential applications to technical submicron structures are discussed.
Anhand von computertomografischen Messungen und Modellrechnungen werden DIRECTT-Rekonstruktionen im Vergleich mit gefilterten Rückprojektionen bewertet. Dazu wird die Rekonstruktionsqualität mittels einer zirkular erweiterten Modulations-Transfer-Funktion (MTF) und mit integralen Kenngrößen im Radon- und im Ortsraum verglichen. Zur Überprüfung der Rekonstruktionsgenauigkeit experimenteller Daten werden Mustermessungen einfacher Probengeometrien unter definierten physikalischen Bedingungen durchgeführt. Diese beinhalten die Monochromasie, die Unterdrückung von Kantenartefakten und die radiometrische Intensitätsbestimmung. Für die Qualität der Rekonstruktionen mittels DIRECTT erweisen sich sowohl unterschiedliche Rekonstruktionsfilter als auch der Verzicht auf jede Filterung als unerheblich, im Gegensatz zur gefilterten Rückprojektion.
Die durch Brechung an Mikrostrukturen abgelenkte Röntgenstrahlung wird direkt zweidimensional abgebildet. Dazu werden Modellproben einfacher Geometrie (Fasern, Kapillaren, monodisperse Nano- und Mikropartikel) mit einem auf 50 µm kollimierten Synchrotronstrahl (20 keV) gescannt. Die nach den Regeln der geometrischen Optik an prismatischen und linsenartigen Grenzflächen abgelenkte Strahlung wird in etwa 3 Metern Entfernung von einem Flächendetektor mit 7 µm Ortsauflösung zusätzlich zu der ungestörten Resttransmission des Primärstrahls registriert. In der Abfolge der Radiogramme werden die lokalen Orientierungsänderungen der Probekörper-Grenzflächen bei deren Abtastung mit wenigen Mikrometern Schrittweite bildhaft verfolgt. Mit der hier erreichten Winkelauflösung von etwa 3 Bogensekunden (Streuvektor-Inkremente Δk = 10-3nm-1) kann bei 50 µm Ortsauflösung das Materialvolumen bezüglich innerer Grenzflächen mit Nanometer-Separation auch bei hohen Abtastraten unterhalb einer Sekunde pro Bild charakterisiert werden.
The relevance of nano sized structures and interfaces in upcoming technologies requires new non-destructive Xray
techniques exploiting attenuation as well as scattering. In the course of driving the resolution and the contrast
of modern radiography into micro and nano metre dimension the inevitable scattering effects require increased
attention. Several radiologists interpret the observed edge artefacts simply by 'phase contrast' due to different
X-ray path lengths within the sample and others refer to Fresnel scattering. The ultra small angle scattering is of
high intensity and may reach the level of the primary beam. We present monochromatic synchrotron
measurements on rather simply shaped objects (such as plates and cylinders) which prove clearly the dominance
of refraction intensity over total reflection and coherent small angle scattering. The refraction conditions hold for
angles of incidence of several degrees to the surface, but typical deflection angles range from several seconds to
minutes of arc. Additionally to the concept of 'phase contrast' of the primary beam its deflection becomes the
essential issue. The appropriate removal of the attenuation contribution enables the imaging of inner surfaces and
interfaces by refraction scanning topography. The presented measurements of reference particles demonstrate the
reliability of laboratory refraction scanners applying X-ray tubes.
Hinterleuchten stellt eine oft unerkannte Fehlweisung in der radiographischen Abbildung mit Flächendetektoren dar, die durch diffuse Umverteilung der Intensität verursacht wird. Dieser Effekt kann die korrekte Transmissions-Intensität eines Probekörpers gemäß dem Lambert-Beer'schen Gesetz erheblich verfälschen. Hinterleuchten wird sowohl mit Bremsstrahlung von Röntgenröhren als auch mit monochromatischer Synchrotronstrahlung beobachtet. Die fehlerhaft reduzierten Schwächungskoeffizienten von einigen 10 % korrelieren mit der Strahlschwächung und dem direkt bestrahlten Detektorbereich. Für eine einfache numerische Korrektur des Hinterleuchtens werden lediglich integrale Intensitätswerte benötigt.
Evaluating porosity in cordierite diesel particulate filter materials, part 1 X-ray refraction
(2013)
Bi-continuous porous ceramics for filtration applications possess a particularly complicated microstructure, with porosity and solid matter being intermingled. Mechanical, thermal, and filtration properties can only be precisely estimated if the morphology of both solid matter and porosity can be quantitatively determined. Using x-ray absorption and refraction, we quantitatively evaluate porosity and pore orientation in cordierite diesel particulate filter ceramics. Porosity values turn out to agree with mercury intrusion measurements, while pore orientation factors agree with published crystallographic texture data.
Complementary to Part 1 of this work, the bi-continuous microstructure of porous synthetic cordierite ceramics for filtration applications was investigated using 3D x-ray computed tomography at different resolutions. Applying both Fast Fourier Transform and a newly developed image analysis algorithm, we quantitatively evaluated porosity and pore orientation. The statistical approach allows extraction of spatially resolved or average values. Porosity values based on x-ray absorption agree with mercury intrusion measurements, while pore orientation factors agree with x-ray refraction data (Part 1 of this work), and with published crystallographic texture data.
Bi-continuous porous ceramics for filtration applications possess a particularly complicated microstructure, whereby porosity and solid matter are intermingled. Mechanical, thermal, and filtration properties can only be precisely estimated if the morphology of both solid matter and porosity can be quantitatively determined. Using 3D computed tomography (CT) at different resolutions, and several X-ray refraction-based techniques, we quantitatively evaluated porosity and pore orientation in cordierite diesel particulate filter ceramics.Moreover, applying both Fast Fourier Transform (FFT) and a newly developed image analysis algorithm (directional interface variance analysis, DIVA), we quantitatively evaluated porosity and pore orientation. Both the experimental techniques and the statistical approach allow extraction of spatially resolved or average values.Porosity values from synchrotron computed tomography used turn out to agree with mercury intrusion measurements, while pore orientation factors agree with published crystallographic texture data. This latter point also implies that the study of the pore/matter interface is sufficient to describe the morphological properties of these materials.
The use of high brilliance and partial coherent synchrotron light for radiography and computed tomography (CT) allows to image micro-structured, multi-component specimens with different contrast modes and resolutions up to submicrometer range. This is of high interest for materials research, life science and non-destructive evaluation applications. An imaging setup for microtomography and radiography installed at BESSY II (a third generation synchrotron light source located in Berlin, Germany) as part of its first hard X-ray beamline (BAMline) can now be used for absorption, refraction as well as phase contrast dedicated to inhouse research and applications by external users. Monochromatic synchrotron light between 6 keV and 80 keV is attained via a fully automated double multilayer monochromator. For imaging applications the synchrotron beam transmitted by the sample is converted with a scintillator into visible light. By use of microscope optics this luminescence image is then projected onto, e.g., a CCD chip. Several scintillating materials are used in order to optimise the performance of the detector system. Different optical systems are available for imaging ranging from a larger field of view and moderate resolutions (macroscope up to 14 mm x 14 mm field of view) to high resolution (microscope down to 0.35 μm pixel size), offering magnifications from 1.8× to 40×. Additionally asymmetric cut Bragg crystals in front of the scintillator can be used for a further magnification in one dimension by a factor of about 20. Slow and fast cameras are available, with up to 16 bit dynamic range. We show the suitability of the setup for numerous applications from materials research and life science.
Die mitunter erhebliche Verschmierung von computertomograpischen Projektionen durch ausgedehnte Strahlenquellen wird durch eine neuartige Entschmierungsprozedur erheblich reduziert, um eine verbesserte Ortsauflösung der Rekonstruktion zu erreichen. Da die Breite der Verschmierungsfunktion der detektornahen und -fernen Objektelemente sich erheblich unterscheiden kann, muss die Entschmierung variabel sein. Im Gegensatz zu einer für alle Voxel-Positionen identischen Entfaltung, also einer grundsätzlich falschen Voraussetzung, wurde eine implizite Entschmierung entwickelt. Die vorab bekannte positionsabhängige Verschmierung wird auf die iterativ wiederholten Projektionen der Teilrekonstruktionen des DIRECTT-Algorithmus angewandt. Die variabel entschmierten Rekonstruktionen aus den Sinogrammen eines Pixelmodells mit Verschmierungen von 1 bis 5 Pixel erreichen eine Ortsauflösung von nahezu einem Pixel.
The combination of tomographic, microstructural data with other experimental techniques and with modeling is paramount, if we want to extract the maximum amount of information on material and component properties. In particular, quantitative image analysis, statistical approaches, direct discretization of tomographic reconstructions represent concrete possibilities to extend the power of the tomographic 3D representation to insights into the material and component performance. This logic thread holds equally for industrial and academic research, and valorizes expensive experiments such as those carried out at synchrotron sources, which cannot be daily repeated. We shall show a few examples of possible use of X-ray tomographic data for quantitative assessment of damage evolution and microstructural properties, as well as for non-destructive testing. We will also show how X-ray refraction computed tomography (CT) can be highly complementary to classic absorption CT, being sensitive to internal interfaces.
In den unterschiedlichsten Methoden der Computertomographie tritt häufig ein diffuses Untergrundsignal in den Einzelprojektionen auf: im Falle der Parallelstrahl-CT mit Synchrotronstrahlung handelt es sich um ein Hinterleuchten durch den Fluoreszenzschirm, der vor der CCD-Kamera angeordnet ist. Dieses Hinterleuchten unterscheidet sich von dem bekannten Nachleuchten (Phosphoreszenz) durch zeitliche Konstanz.
Hier äußert sich das Hinterleuchten als Modulation der projizierten Masse und somit als Funktion der Phase (Projektionswinkel) und des Aspektverhältnisses des Objektes. Der Einfluss des Hinterleuchtens ist abhängig von der Größe des von der Probe abgeschatteten Detektorbereiches und des Objektumfangs (Dynamik). Dies hat u.a. zur Folge, dass Abweichungen vom Absorptionsgesetz auftreten, die umso
stärker ausgeprägt sind, je weniger Detektorfläche das Objekt abdeckt und je stärker das Objekt schwächt. Dabei können Aufhärtungseffekte wegen der monochromatischen Strahlung ausgeschlossen werden.
Mit Referenzmessungen und einem isotropen, homogenen Ansatz, der diese Abweichung als Hinterleuchten beschreibt, lassen sich die auftretenden Fehler deutlich verringern.
Beyond classical X-ray techniques are used for the purpose of preferably short-term applications, but some supplementary X-ray and synchrotron techniques for higher resolution microdiagnostics take advantage of scattering effects. In contrast to directly imaging methods their resolution is only limited by the diffraction limit of the X-ray wavelength, far below the atomic dimensions. These techniques of scanning topography and refraction synchrotron tomography may permit the systematic diagnostics for finding and exploiting structure/property relations like correlations among atomic, nano and microstructures with macroscopic properties. Their basic advantage over microscopic techniques is their potential for the non-destructive characterisation of materials, far from invasive sample treatments. They combine scattering and spatial resolution.
Die Computertomographie (CT) ist in der Medizin als Standardtechnik etabliert, in der zerstörungsfreien Prüfung wird sie zunehmend angewendet, in einzelnen Fällen sogar als Referenzverfahren eingesetzt. Gegenwärtig ist eine starke Zunahme von Anwendungen der CT in der Materialcharakterisierung zu verzeichnen. Zudem werden weitere moderne 3D-Techniken für werkstoffwissenschaftliche Fragestellungen genutzt, um die Mikrostruktur - auch in situ (z.B. Druck, Temperatur) - aufzuklären. Hier werden neben der konventionellen Absorptions-CT auch die Potenziale der Refraktions-CT zur Beantwortung prozesstechnischer sowie werkstofflicher Fragestellungen aufgezeigt, die ein „ganzheitliches Bild“ des jeweiligen Werkstoffs zum Ziel haben.
Non-destructive evaluation of advanced materials by synchrotron radiation refraction topography
(2002)
A novel approach to strongly suppress artifacts in radiography and computed tomography caused by the effect of diffuse background signals ('backlighting') of 2D X-ray detectors is suggested. Depending on the detector geometry the mechanism may be different, either based on the optical scattering by the fluorescent screen materials into optical detection devices or Compton or X-ray fluorescence scattering by the detector components. Consequently, these erroneous intensity portions result in locally different violations of Lambert–Beer's law in single projections (radiographs). When used as input data for computed tomography these violations are directly observed via modulation of the projected mass as a function of the rotation phase and the samples aspect ratio (dynamics). The magnitude of the diffuse background signal depends on the detector area covered by the projected sample. They are more pronounced the smaller the shadowed area and the stronger the total attenuation. This implies that the reconstruction suffers from additional anisotropic artifacts caused by elongated sample structures. This issue is studied simply by absorption of flat plates in a conventional laboratory radiography set-up and at a synchrotron radiation facility. In the latter case beam hardening artifacts can be excluded due to the monochromatic radiation. The proposed correction procedure requires simple integral intensity offsets as a constant (non-local) light scattering mechanism is assumed.
Eine neuartige Korrektur artefaktisch gemessener Intensitäten von Röntgenflachdetektoren wird vorgeschlagen. Die betrachteten Artefakte betreffen eine diffuse Umverteilung der Intensität und führen zu beträchtlichen Verfälschungen der wahren Schwächung und verletzen mithin das Lambert-Beer'sche Gesetz.
Sie werden sowohl in Laborexperimenten mit Röntgenröhren (polychromatische Einstrahlung) als auch mit monochromatischer Synchrotronstrahlung bei Einsatz indirekt konvertierender Detektionssysteme (Fluoreszenzschirm, Optik, CCD-Chip) beobachtet.
Dieser Effekt wird als Hinterleuchten bezeichnet.
In der vorgestellten Studie werden mittels wohldefinierter Randbedingungen Gesetzmäßigkeiten des Hinterleuchtens untersucht: durch Einsatz monochromatischer Strahlung können Aufhärtungseffekte als Ursache ausgeschlossen werden. Das Hinterleuchten ist umso stärker ausgeprägt, je weniger Detektorfläche vom Objekt abdeckt wird und je stärker das Objekt schwächt. Mit Blick auf Tomographien ergibt sich eine Modulation der 'Dichte' als Funktion des Projektionswinkels, deren Amplitude mit dem Objektumfang steigt (Dynamik).
Der isotrope und homogene Ansatz zur numerischen Korrektur macht lediglich Gebrauch von Intensitätsmittelwerten und stellt die Gültigkeit des Schwächungsgesetzes in modifizierter Form wieder her.
The performance of grating interferometers coming up now for Imaging interfaces within materials depends on the efficiency (visibility) of their main component, namely the phase grating. Therefore, experiments with monochromatic synchrotron radiation and corresponding simulations are carried out. The visibility of a Phase grating is optimized by different photon energies, varying detector to grating distances and continuous rotation of the phase grating about the grid lines. Such kind of rotation changes the projected grating shapes, and thereby the distribution profiles of phase shifts. This yields higher visibilities than derived from ideal rectangular shapes. By continuous grating rotation and variation of the propagation distance, we achieve 2D visibility maps. Such maps provide the visibility for a certain combination of grating orientation and detector position. Optimum visibilities occur at considerably smaller distances than in the standard setup.
Erstmals wurden MMCs mit Hilfe der Interface-Kontrast verstärkenden Röntgen-Refraktions-Technik in Kombination mit der 3D-CT-Technik untersucht. Die Methode der Röntgen-Refraktions-Topography sowie der Röntgen-Refraktions-Tomography wurden in den letzten Jahren speziell für die zerstörungsfreie Charakterisierung von Leichtbau-Hochleistungs-Werkstoffen wie Verbund-Werkstoffen und Keramiken entwickelt. Die Technik basiert auf der Refraktion von Röntgenlicht an Grenzflächen zwischen Bereichen unterschiedlicher Elektronendichte wie z.B. Faser- und Matrix-Werkstoff. Auf Grund der kurzen Röntgen-Wellenlänge hat der Brechungsindex einen Wert dicht bei eins, sodass der Streuwinkel nur wenige Bogenminuten beträgt. Der Vorteil der kurzen Wellenlänge besteht jedoch darin, dass Poren und Risse detektiert werden können, deren Größe im Nanometerbereich liegen. Damit kann die Refraktions-Technik zum besseren Verständnis von Mikro- und Submikro-Strukturen in der Materialwissenschaft eingesetzt werden. Mit der hier vorgestellten Refraktions-CT wurden Ermüdungsmechanismen an MMCs, bestehend aus SiC-Faser verstärktem Titan (Ti6242) untersucht. Die Messungen wurden am Röntgen-Messplatz der BAM (BAMline) am Synchrotron-Speicherring-BESSY in Berlin Adlershof durchgeführt.
Rekonstruktion unvollständiger computertomografischer Modelldatensätze mit Directt-Algorithmus
(2010)
Modellrechnungen zur Rekonstruktion unvollständiger computertomographischer Datensätze werden zur Ermittlung der Vorteile des neuen Directt-Algorithmus gegenüber der konventionellen gefilterten Rückprojektion durchgeführt, insbesondere auch zur Vermeidung experimentell begründeter Unwägbarkeiten. Ein entsprechender Bedarf entsteht seitens erweiterter Forschungsaktivitäten und industrieller Bedürfnisse, wo die Rekonstruktion limitierter Messdatensätze von Artefakten dominiert wird. Die bekanntesten Einschränkungen betreffen das Limited-View- und Few-Angles-Problem sowie die ROI-Situation, die jeweils unabhängig voneinander untersucht werden, in der Anwendung jedoch zumeist undefiniert vermischt sind, wie etwa in der Elektronen-Tomografie. Die hochauflösende Rekonstruktion von Einzelpixeln wird durch die Wahl eines kleinen Modells von nur 1012 Pixeln visualisiert und ist ohne Filterung möglich. Rekonstruktionen von 90°-Sektoren oder 50 % -ROI-Querschnitten sind fast ohne Auflösungseinschränkungen realisierbar. Die bisher nicht bekannte Möglichkeit, auch außerhalb der ROI präzise zu rekonstruieren, wurde als "Extended ROI"-Methode erfolgreich erprobt.
Es wird ein Verfahren zur Röntgenabbildung schwach absorbierender Objekte vorgestellt. Als kontrastgebender Effekt wird die Röntgenrefraktion an Ober- und Grenzflächen ausgenutzt. Zur Erzeugung eines sogenannten Dunkelfeldes wird ein schwach gekrümmter Transmissionskristall eingesetzt, der lokal, d.h. in einem kleinen Ausschnitt des Einstrahlquerschnitts, die Bragg-Bedingung erfüllt. Innerhalb dieser Zone erscheinen die durch Refraktion abgelenkten Strahlkomponenten als hell leuchtende Interface-Strukturen. Die Synthese mehrerer Dunkelfeldstreifen ergibt hochaufgelöste 2D Beispiel von biologischen und technischen Mikrostrukturen.
Für die Charakterisierung Neuer Werkstoffe, vornehmlich Nichtmetalle, hat sich das Verfahren der Röntgen-Refraktions-Topographie bewährt. Es handelt sich phänomenologisch um eine Technik der Röntgen-Kleinwinkel-Streuung mit Probekörper-Abtastung bei fest vorgewähltem Streuwinkel. Gegenüber der klassischen Beugungstheorie dominieren jedoch bei der Streuung an Strukturen oberhalb von 0.3 µm Größe röntgenoptische Brechungseffekte. Detektierbar sind damit innere Ober- und Grenzflächen, insbesondere Mikrorisse unterhalb der lichtmikroskopischen Erkennbarkeit. Da es sich hierbei um eine Durchstrahlungs-Technik handelt, überlagern jedoch die Strukturen zu einer Projektion, analog zu den radiographischen Verfahren.
Um auch Informationen entlang der Durchstrahlungs-Richtung in der Tiefe des Probekörpers zu erhalten, wird unter kleinen Streuwinkeln die Computer-Tomographie durchgeführt, im ersten Ansatz mit nur zwei Meßkanälen, jeweils für die Messung der Absorptions- und der Refraktions-Intensität. Dazu werden nacheinander 360 Linear-Scans nach Drehung von jeweils 1° aufgenommen. Die Intensitätswerte werden nach den Regeln der fouriergefilterten Rückprojektion zu Computer-Tomogrammen verarbeitet.
Die Ergebnisse visualisieren die Anordnung von Grenzflächen und innere Oberflächen, die sich für zahlreiche nichtmetallische Werkstoffe, vor alllem im Transportmittel-Leichtbau als relevante Mikrostrukturen für das Versagens-Verhalten und die Werkstoff-Optimierung eignen. Zum Vergleich entstehen aus den simultanen Absorptionsmessungen gleichzeitig die klassischen Computer-Tomogramme, die ausschließlich Dichteänderungen anzeigen.