Filtern
Erscheinungsjahr
Dokumenttyp
- Vortrag (45)
- Beitrag zu einem Tagungsband (34)
- Posterpräsentation (24)
- Beitrag zu einem Sammelband (20)
- Zeitschriftenartikel (11)
- Sonstiges (8)
- Buchkapitel (2)
Referierte Publikation
- nein (144) (entfernen)
Schlagworte
- X-ray refraction (17)
- Computed tomography (7)
- Röntgen-Refraktion (7)
- Computed Tomography (6)
- Keramik (6)
- Röntgenrefraktion (6)
- Synchrotron (5)
- Synchrotron radiation (5)
- Composites (4)
- Materialcharakterisierung (4)
Organisationseinheit der BAM
Eingeladener Vortrag
- nein (45)
We investigated to our knowledge for the first time the capabilities of long period gratings (LPG) in single-mode microstructured polymer optical fibre (mPOF) as real-time gamma dosimeter. The fibre is made from polymethyl methacrylate (PMMA) with a polycarbonate jacket. We measured the radiation-induced wavelength shift of the mPOF LPG loss feature wavelength and the radiation-induced attenuation of a mPOF for
different wavelength between 600 nm and 800 nm for gamma radiation with an energy distribution between 6 keV and 18 keV.
Proben mit einer Mittelkerbe aus Polyamid 66 mit 35% Gewichtsan-teil an Kurzglasfaser (PA-GF35) wurden im Spritzgießverfahren hergestellt und in einem ungeschädigten und durch Schwingbeanspruch geschädigten Zustand mittels Röntgenverfahren charakterisiert. Sowohl die Faserorientierungsverteilung als auch die Riss-/Mikrorissbildung wurden mit der Röntgenrefraktionstopographie in einem SAXS-Aufbau und dem Diffraction-Enhanced-Imaging am Synchrotron (BESSY II) analysiert. Beide Verfahren spiegeln in guter Übereinstimmung die Charakteristiken dieser Werkstoffklasse in Bezug auf die Fertigungsqualität und die Schädigungsme-chanismen wider.
Im vergangenen Jahrzehnt sind gitterinterferometrische Röntgenabbildungen zunehmend in den Fokus des Interesses gerückt. Sie sind insbesondere dann Vorteil, wenn der in der Standardradiographie erreichbare Kontrast nicht genügt, schwach absorbierende Mikro- und Nanostrukturen abzubilden.
Auf Kosten mehrerer Aufnahmen gestattet die Talbot-Lau Gitterinterferometrie, die Beiträge aus Absorption, Refraktion und (refraktiver) Streuung zu trennen. Dazu werden die Störungen der Interferenzmuster von Phasengittern ausgewertet. Im Gegensatz zu einer Vielzahl anderer refraktionsbasierter Abbildungsmethoden kann diese Technik mit konventionellen Röntgenröhren (mit divergenter, polychromatischer Strahlung) angewendet werden. Damit ist die Technik geeignet, typische ZfP-Fragestellungen zu lösen.
Hier stellen wir Untersuchungen zur Effizienz von Phasengittern vor. Die Visibilität (d.h. die Höhe der Oszillation im Interferenzmuster) wird als Funktion verschiedener geometrischer Parameter verfolgt. Eine Rotation um die Achse parallel zu den Gitterstegen ändert die Form des Gitterprofils (d.h. die Verteilung der Phasenschiebungen). Die kontinuierliche Variation des Winkels und des Detektionsabstandes führt zur Identifikation von ausgezeichneten Kombinationen mit maximaler Visibilität, wobei die Abstände deutlich geringer sind als im Standardaufbau mit senkrechter Gitterbestrahlung.
Unsere Studie umfasst Simulationen für monochromatische Quelle und den Vergleich zu experimentellen Ergebnissen mit der Synchrotronstrahlung.
In der Literatur wurden die Vorteile der Talbot-Lau Interferometrie für die zerstörungsfreie Prüfung von Faserkompositen und Verbundwerkstoffen demonstriert. Hier werden als Beispiele Messungen an Aluminiumtitanat (Al2TiO5) Pulver gezeigt.
Grating interferometric set-ups have been established in the last decade. They are promising candidates to obtain enhanced image contrast from weakly absorbing micro and nano structures. They are based on X-ray refraction and near-field diffraction using the Talbot effect.
At the expense of taking multiple images, Talbot-Lau grating interferometry allows separating the absorption, refraction, and scattering contributions by analysing the disturbances of a phase grating interference pattern. Contrary to other refraction enhanced methods, this technique can be applied using conventional X-ray tubes (divergent, polychromatic source). This makes it attractive to solve typical non-destructive testing problems.
We investigated the efficiency of phase gratings, i.e. the visibility (the amplitude of oscillations) upon variation of propagation distance and phase grating rotation around an axis parallel to the grid lines. This grating rotation changes the grating shape (i.e. the distributions of phase shifts). This can yield higher visibilities than derived from rectangular shapes.
Our study includes experimental results obtained from synchrotron radiation, as well as simulations for monochromatic radiation. The advantages of Talbot-Lau interferometry are demonstrated at the example of glass capillaries.
Röntgen-Topographie mit Klein- und Weitwinkel-Streuung und Röntgenrefraktions-Computertomographie
(2003)
The high-resolution synchrotron-based imaging stations at the BAMline (BESSY) and TopoTomo (ANKA)
(2008)
The BAMline at the BESSY light source in Berlin and the TopoTomo beamline at the ANKA synchrotron facility in Karlsruhe (both Germany) operate in the hard X-ray regime (above 6 keV) with similiar photon flux density. For typical imaging applications, a double multilayer monochromator or a filtered white beam is used. In order to optimise the field of view and the resolution of the available indirect pixel detectors, different optical systems have been installed, adapted, respectively, to a large field of view (macroscope) and to high spatial resolution (microscope). They can be combined with different camera systems, ranging from 16-bit dynamic range slow-scan CCDs to fast CMOS cameras. The spatial resolution can be brought substantially beyond the micrometer limit by using a Bragg magnifier. The moderate flux of both beamlines compared to other 3rd generation light sources is compensated by a dedicated scintillator concept. For selected applications, X-ray beam collimation has proven to be a reliable approach to increase the available photon flux density. Absorption contrast, phase contrast, holotomography and refraction-enhanced imaging are used depending on the application. Additionally, at the TopoTomo beamline digital white beam synchrotron topography is performed, using the digital X-ray pixel detectors installed.
Complementary to Part 1 of this work, the bi-continuous microstructure of porous synthetic cordierite ceramics for filtration applications was investigated using 3D x-ray computed tomography at different resolutions. Applying both Fast Fourier Transform and a newly developed image analysis algorithm, we quantitatively evaluated porosity and pore orientation. The statistical approach allows extraction of spatially resolved or average values. Porosity values based on x-ray absorption agree with mercury intrusion measurements, while pore orientation factors agree with x-ray refraction data (Part 1 of this work), and with published crystallographic texture data.
Die Integrität der Verstärkungsfasern in Komposit-Zahnstiften ist entscheidend für die Biegefestigkeit und die langfristige Haftung am Zement in den Wurzelkanälen. Es wurde vermutet, dass die Integrität von glasfaserverstärkten Zahnstiften durch das Beschleifen während der zahnmedizinischen Behandlung beeinträchtigt wird. Eine Beschädigung der Fasern führt zu einer erheblichen strukturellen Schwächung über den gesamten Stiftdurchmesser. Glasfragmente, die durch den Kontakt mit dem Zahnbohrer entstehen, können sich vom Stift lösen und die Haftfähigkeit erheblich verringern. Mit Hilfe hochauflösender Synchrotron-Röntgen-Refraktions-Radiographie (SXRR) konnte das Ausmaß der Schäden zuverlässig identifiziert und charakterisiert werden.
Dazu wurden die Glasfaserstifte sowohl im Herstellungszustand als auch nach der Bearbeitung mit einem Diamantbohrer untersucht. Die Datensätze wurden zur Visualisierung und Quantifizierung der morphologischen Charakteristika intakter und durch das Beschleifen beschädigter Regionen analysiert. Sie zeigen Schäden im bearbeiteten Bereich (z. B. Brüche, Splitter und Risse) sowie herstellungsbedingte Inhomogenitäten der Fasern mit einer signifikanten Zunahme der inneren Oberflächen in Probenregionen, die durch das Beschleifen beschädigt wurden.
Die Degradation von Wärmedämmschichten(thermal barrier coatings - TBCs) in Gasturbinen durch glasartige Calcium-Magnesium-Aluminiumsilikat (CMAS)Ablagerungen aus verschiedenen Quellen istseit vielen Jahren ein anhaltendes Problem. In dieser Studie wurde mit Hilfe derSynchrotron-Röntgen-Refraktions-Radiographie (SXRR), und vergleichend mit der Elektronenmikroskopie, das Eindringen von CMAS in die poröse Struktur von atmosphärisch plasmagespritzten (APS)TBCs sowie die Bildung und das Wachstum von Rissen unter thermisch zyklischer Belastung untersucht. Die Ergebnisse deuten darauf hin, dass die Infiltration sowie deren Kinetik im Brenner-Teststand wesentlich vom Benetzungsverhalten des CMAS beeinflusst werden. Trotz desoffensichtlichen Angriffs von CMAS auf die Korngrenzen hat die Wechselwirkung von Yttriumdioxid-stabilisiertem Zirkoniumdioxid (YSZ) mit intrudiertem CMAS keinen unmittelbaren Einfluss auf die Struktur und Dichte der innen Oberflächen(Risse, Poren). In einem späteren Stadium wird die Bildung von Rissen senkrecht zur äußeren Oberfläche in einer breiteren Zone der TBC-Schicht beobachtet.
Eine neuartige Korrektur artefaktisch gemessener Intensitäten von Röntgenflachdetektoren wird vorgeschlagen. Die betrachteten Artefakte betreffen eine diffuse Umverteilung der Intensität und führen zu beträchtlichen Verfälschungen der wahren Schwächung und verletzen mithin das Lambert-Beer'sche Gesetz.
Sie werden sowohl in Laborexperimenten mit Röntgenröhren (polychromatische Einstrahlung) als auch mit monochromatischer Synchrotronstrahlung bei Einsatz indirekt konvertierender Detektionssysteme (Fluoreszenzschirm, Optik, CCD-Chip) beobachtet.
Dieser Effekt wird als Hinterleuchten bezeichnet.
In der vorgestellten Studie werden mittels wohldefinierter Randbedingungen Gesetzmäßigkeiten des Hinterleuchtens untersucht: durch Einsatz monochromatischer Strahlung können Aufhärtungseffekte als Ursache ausgeschlossen werden. Das Hinterleuchten ist umso stärker ausgeprägt, je weniger Detektorfläche vom Objekt abdeckt wird und je stärker das Objekt schwächt. Mit Blick auf Tomographien ergibt sich eine Modulation der 'Dichte' als Funktion des Projektionswinkels, deren Amplitude mit dem Objektumfang steigt (Dynamik).
Der isotrope und homogene Ansatz zur numerischen Korrektur macht lediglich Gebrauch von Intensitätsmittelwerten und stellt die Gültigkeit des Schwächungsgesetzes in modifizierter Form wieder her.
For the first time Metal Matrix Composites (MMC) have been investigated by 3D Computed Tomography combined with enhanced interface contrast due to X-ray refraction. X-ray refraction is a relatively new approach for the characterization of advanced materials. The related techniques of Refraction Topography and Refraction Computed Tomography have been developed and applied at our laboratory during the last decade to meet the actual demand for improved nondestructive characterization of high performance composites, ceramics and other low density materials and components. X-ray refraction occurs, when X-rays crosses interfaces of spherical or cylindrical shape (e.g. pores or fibres) in the same way as visible light is refracted by lenses. These X-ray optical effects can be observed at small scattering angles of few minutes of arc as the refractive index n of X-rays is nearly unity (n = 1 10-6). Due to the short X-ray wavelength of about 0.1 nm the technique determines the amount of inner surfaces and interfaces of nanometer dimensions. The technique is expected to solve many problems in understanding the meaning of micro and sub micro structures in materials science. With the results of the CT investigation, some questions could be clarified for a better understanding of fatigue failure mechanisms under cyclic loading conditions. The specimens for the test programme have been provided by MTU Aero Engines. They consist of a titanium matrix (Ti6242) reinforced by SiC fibres (SCS6). The investigations have been performed at the materials research station of BAM (BAMline) at the Synchrotron Facility BESSY in Berlin, Germany.