The first hard X-ray beamline at BESSY II will be installed by BAM and PTB at a superconducting 7 T wavelength shifter. The main optical elements of the beamline are a Double-Multilayer-Monochromator and a Double-Crystal-Monochromator. The two devices can be used separately or in-line. Main applications of monochromatic radiation with photon energies up to 50 keV are X-ray fluorescence analysis, micro-computed tomography, X-ray topography, detector calibration and reflectometry. Calculable undispersed radiation up to 200 keV will be available for radiometric applications.
The first hard x-ray beamline at BESSY II has been installed by BAM and PTB at a superconducting 7 T wavelength shifter. The main optical elements of the beamline are a double-multilayer monochromator and a double-crystal monochromator. Depending on the application, the two devices are used separately or in-line. The main applications of the monochromatic radiation with photon energies up to 60 keV are x-ray fluorescence analysis, micro computed tomography, x-ray topography, detector calibration and reflectometry. Calculable undispersed radiation up to 200 keV is available for radiometric applications.
The employment of synchrotron radiation for refraction topography of materials has considerable advantages over standard x-ray sources. The much higher beam intensity and the parallel and monochromatic radiation provide faster measurements and better angular and spatial resolution. X-ray refraction techniques image the inner surface and interface concentration of micro-structured materials. This effect of x-ray optics is additional to small-angle scattering by diffraction, when the scattering objects reach micrometre dimensions. We have developed x-ray refraction techniques within the last decade in order to meet the growing demands for improved non-destructive characterization of high-performance composites, ceramics and other low-density materials. Sub-micron particle dimensions, the pore size of ceramics, the crack density distribution and single fibre debonding within damaged composites can be measured and visualized by computer-generated interface topographs. For this purpose investigations are now being performed at the new hard x-ray beamline of the Federal Institute for Materials Research and Testing (BAM) at BESSY, Berlin. This BAMline provides monochromatic radiation of photon energies from 5 to 60 keV from a double multilayer and/or a double-crystal monochromator. A separate instrument is dedicated to the further development and application of synchrotron radiation refraction (SRR) topography. Different from conventional small-angle scattering cameras with collimating slits and pinholes, scattering angles down to a few seconds of arc are selected by a single-crystal analyser, similar to a Bonse-Hart diffractometer. A 20 µm spatial resolution of the scattering micro-structures is achieved by a CCD camera with a fluorescent converter. First SRR topographs of aircraft composites [carbon fibre-reinforced plastics (CFRP), carbon fibre-reinforced ceramics (C/C), metal matrix ceramics (MMC)] will be reported.
A novel approach is suggested to strongly suppress artifacts in radiography and computed tomography caused by the effect of diffuse background signals 'backlighting' of 2D X-ray detectors. Depending on the detector geometry the mechanism may be different. Either based on the optical scattering of the fluorescent screen materials into the optical detection devices or Compton or X-ray fluorescence scattering by the detector components. Consequently, these erroneous intensity portions result in locally different violations of Lambert Beer's law in single projections (radiographs) as a function of the detector area coverage and the magnitude of the attenuation. The absorption of multiple metal sheets is investigated by monochromatic synchrotron radiation, thus excluding beam hardening. The proposed correction procedure simply requires the individual subtraction of one and the same fraction of the primary and transmitted mean intensity, as a constant (non-local) scattering mechanism is assumed.
A novel approach to strongly suppress artifacts in radiography and computed tomography caused by the effect of diffuse background signals ('backlighting') of 2D X-ray detectors is suggested. Depending on the detector geometry the mechanism may be different, either based on the optical scattering by the fluorescent screen materials into optical detection devices or Compton or X-ray fluorescence scattering by the detector components. Consequently, these erroneous intensity portions result in locally different violations of Lambert–Beer's law in single projections (radiographs). When used as input data for computed tomography these violations are directly observed via modulation of the projected mass as a function of the rotation phase and the samples aspect ratio (dynamics). The magnitude of the diffuse background signal depends on the detector area covered by the projected sample. They are more pronounced the smaller the shadowed area and the stronger the total attenuation. This implies that the reconstruction suffers from additional anisotropic artifacts caused by elongated sample structures. This issue is studied simply by absorption of flat plates in a conventional laboratory radiography set-up and at a synchrotron radiation facility. In the latter case beam hardening artifacts can be excluded due to the monochromatic radiation. The proposed correction procedure requires simple integral intensity offsets as a constant (non-local) light scattering mechanism is assumed.
Synchrotron X-ray radiography and tomography investigations of a custom-made polymer electrolyte membrane fuel cell optimised for visualisation purposes are presented. The 3D water distribution and transport pathways in the porous carbon fibre gas diffusion layers (GDLs) were investigated. The authors found that water is not only moving from the GDL into the channel, but can also take the opposite way, that is, from the channel into free pore space of the GDL. Such movement of water into the opposite direction has been subject of speculations but has so far not yet been reported and might bring new insights into the general water transport behaviour, which might give new aspects to the general description of water transport processes and influence modelling assumptions to describe the process taking place in the GDL.
The use of high brilliance and partial coherent synchrotron light for radiography and computed tomography (CT) allows to image micro-structured, multi-component specimens with different contrast modes and resolutions up to submicrometer range. This is of high interest for materials research, life science and non-destructive evaluation applications. An imaging setup for microtomography and radiography installed at BESSY II (a third generation synchrotron light source located in Berlin, Germany) as part of its first hard X-ray beamline (BAMline) can now be used for absorption, refraction as well as phase contrast dedicated to inhouse research and applications by external users. Monochromatic synchrotron light between 6 keV and 80 keV is attained via a fully automated double multilayer monochromator. For imaging applications the synchrotron beam transmitted by the sample is converted with a scintillator into visible light. By use of microscope optics this luminescence image is then projected onto, e.g., a CCD chip. Several scintillating materials are used in order to optimise the performance of the detector system. Different optical systems are available for imaging ranging from a larger field of view and moderate resolutions (macroscope up to 14 mm x 14 mm field of view) to high resolution (microscope down to 0.35 μm pixel size), offering magnifications from 1.8× to 40×. Additionally asymmetric cut Bragg crystals in front of the scintillator can be used for a further magnification in one dimension by a factor of about 20. Slow and fast cameras are available, with up to 16 bit dynamic range. We show the suitability of the setup for numerous applications from materials research and life science.