Filtern
Erscheinungsjahr
Dokumenttyp
- Posterpräsentation (15)
- Zeitschriftenartikel (9)
- Vortrag (8)
- Beitrag zu einem Tagungsband (3)
Schlagworte
- ELISA (3)
- Mass spectrometry (3)
- Carbamazepine (2)
- Endocrine disruption (2)
- 17α-ethinylestradiol (EE2) (1)
- Acoustic cavitation (1)
- Anion exchange (1)
- Arzneimittelrückstände in Oberflächenwasserproben (1)
- Bile acids (1)
- CCQM-K126 (1)
Organisationseinheit der BAM
Eingeladener Vortrag
- nein (8)
Enzyme-linked immunosorbent assay (ELISA) for the anthropogenic marker isolithocholic acid in water
(2016)
Bile acids are promising chemical markers to assess the pollution of water samples with fecal material.
This study describes the optimization and validation of a direct competitive enzyme-linked immunosorbent assay for the bile acid isolithocholic acid (ILA). The quantification range of the optimized Assay was between 0.09 and 15 mg/L. The assay was applied to environmental water samples. Most studies until now were focused on bile acid fractions in the particulate phase of water samples. In order to avoid tedious sample preparation, we undertook to evaluate the dynamics and significance of ILA levels in the aqueous phase. Very low concentrations in tap and surface water samples made a pre-concentration step necessary for this matrix as well as for wastewater treatment plant (WWTP) effluent. Mean recoveries for spiked water samples were between 97% and 109% for tap water and WWTP influent samples and between 102% and 136% for WWTP effluent samples. 90th percentiles of intra-plate and inter-plate coefficients of variation were below 10% for influents and below 20% for effluents and surface water. ILA concentrations were quantified in the range of 33-72 mg/L in influent, 21-49 ng/L in effluent and 18-48 ng/L in surface water samples. During wastewater Treatment the ILA levels were reduced by more than 99%. ILA concentrations of influents determined by ELISA and LC-MS/MS were in good agreement.
However, findings in LC-ELISA experiments suggest that the true ILA levels in concentrated samples are lower due to interfering effects of matrix compounds and/or cross-reactants. Yet, the ELISA will be a valuable tool for the performance check and comparison of WWTPs and the localization of fecal matter input into surface waters.
The antiepileptic drug carbamazepine is one of the most abundant pharmaceuticals in the German aquatic environment. The effect of low carbamazepine concentrations (1–50 µg L-1) is discussed controversially, but ecotoxicological studies revealed reproduction toxicity, decreased enzymatic activity and bioaccumulation in different test organisms. Therefore, as a preventive step, an efficient and cost-effective technique for wastewater treatment plants is needed to stop the entry of pharmaceuticals into the aquatic environment. Cavitation, the formation, growth, and subsequent collapse of gas- or vapor-filled bubbles in fluids, was applied to solve this problem. The technique of Hydrodynamic-Acoustic-Cavitation was used showing high synergistic effect. Under optimized conditions carbamazepine (5 µg L-1) was transformed by pseudo-first order kinetics to an extent of >96% within 15 min (27% by hydrodynamic cavitation, 33% by acoustic cavitation). A synergistic effect of 63% based on the sum of the single methods was calculated. Carbamazepine concentrations were monitored by a sensitive and selective immunoassay and after 60 min no known metabolites were detectable by LC-MS/MS.
Pharmaceuticals, certain food ingredients, and mammalian endogenous metabolic products in wastewater are mostly of human origin. They are anthropogenic markers.
Proper knowledge of their levels in wastewater helps to track sources of pollutants in natural waters and allows for calculation of removal efficiencies in wastewater Treatment plants. Here, we describe the development and application of an indirect competitive, multiplexing suspension Array fluorescence immunoassay (SAFIA) for the detection of carbamazepine (CBZ), diclofenac (DCF), caffeine (CAF), and isolithocholic acid (ILA) in wastewater, covering those classes of anthropogenic markers. The assay consists of haptens covalently conjugated to fluorescence-encoded polystyrene core/silica shell microparticles to create a site for competitive binding of the antibodies (Abs). Bound Abs are then stained with fluorophore-labeled Abs. Encoding and signaling fluorescence of the particles are determined by an automated flow cytometer.
For compatibility of the immunoassay with the 96-well microtiter plate format, a stop reagent, containing formaldehyde, is used. This enables a wash-free procedure while decreasing time-to-result. Detection limits of 140 ± 40 ng/L for CBZ, 180 ± 110 ng/L for CAF, 4 ± 3 ng/L for DCF, and 310 ± 70 ng/L for ILA are achieved, which meet the sensitivity criteria of wastewater analysis. We demonstrate the applicability of SAFIA to real wastewater samples from three different wastewater Treatment plants, finding the results in good agreement with LC-MS/MS. Moreover, the accuracy in general exceeded that from classical ELISAs. We therefore propose SAFIA as a quick and reliable approach for wastewater analysis meeting the requirements for process analytical technology.