Filtern
Erscheinungsjahr
Dokumenttyp
Schlagworte
- Haftfestigkeit (6)
- Klebfestigkeit (6)
- Zentrifugentechnologie (6)
- Verbundfestigkeit (5)
- Bonding strength (3)
- Centrifuge technology (3)
- Oberflächenenergie (3)
- ALD-Hybridprozesse (2)
- Adhesive strength (2)
- Air-coupled ultrasound (2)
Organisationseinheit der BAM
Ferroelectrets are promising materials for air-coupled ultrasonic transducers. A transducer made of polarized cellular polypropylene, including its electronic interface, was developed and compared with conventional air-coupled probes. Test pieces of fiber-reinforced polymer containing impact flaws and flat-bottom holes were inspected in transmission. The ferroelectret transducers achieved a considerably higher signal-to-noise ratio. The impacts were clearly visible with all transducers, but less noisy with ferroelectret transducers. The flat-bottom holes were better detectable than with a conventional probe with about the same focus size.
In this contribution we present a novel thermo-acoustic approach for the generation of broad band airborne ultrasound and investigate the applicability of resonance-free thermo-acoustic emitters for very short high pressure airborne ultrasound pulses. We report on measurements of thermo-acoustic emitter consisting of a 30 nm thin metallic film on a usual soda-lime glass substrate, generating sound pressure values of more than 140 dB at 60 mm distance from the transducer and compare the results with conventional piezoelectric airborne ultrasound transducers. Our experimental investigations show that such thermo-acoustic devices can be used as broad band emitters using pulse excitation.
Air-coupled ferroelectret ultrasonic transducers applied to testing of fiber-reinforced polymers
(2013)
A novel approach for the generation of broadband airborne ultrasound by using the thermo-acoustic effect is presented in this contribution. We investigate the applicability of resonance-free thermo-acoustic emitters for generation of very short high pressure airborne ultrasound pulses. A thermoacoustic emitter consisting of a 30 nm thin metallic film on a usual soda-lime glass substrate generates sound pressure values of more than 140 dB at 60 mm distance. The results are compared with conventional piezoelectric airborne ultrasound transducers. Our investigations show the applicability of the thermo-acoustic devices for broadband and high pressure ultrasound emitters using pulse excitation.
The multiple-sample approach by means of centrifugal adhesion testing (CAT-technology) allows the determination of bonding strength of adhesive-bonded joints on a statistical basis of up to eight samples. Therefore, it is obvious to ensure the continuous handling and identical processing of an octet of samples within the entire process chain of wet-chemical cleaning, plasma-chemical pre-treatment, bonding of samples, and testing of bonding strength. Within the multiple-sample bonding set-up (MPKV-technology) a defined bonding pressure can be adjusted regardless the actual number of samples. A comparison of single- and multiple-sample approach is made for bonding strength of selected adhesives, double-sided adhesive tapes and different material combinations [stainless steel (V2A) vs. stainless steel, polyamide (PA), or polypropylene (PP)]. It is shown that both technologies improve reliability of results
Multiple-sample approach: reliable ranking and validated statistics of bonding and adhesive strength
(2014)
Bonding strength of adhesive-bonded joints and adhesive strength of coatings have been exclusively determined in
single-sample tests using a tensile testing machine. Necessarily, the single-sample approach was also applied to the
corresponding bonding procedure. As a consequence, reliability and reproducibility of results were restricted. By
applying the newly introduced centrifuge technology, the multiple-sample approach was realized for simultaneous
tensile testing of up to eight samples under identical conditions without any disturbing shear-force effects. In order to
introduce the multiple-sample approach into the bonding procedure, a hydraulic bonding set-up was developed which
enables identical bonding pressure also for slightly different heights of sample assemblies. Both sample approaches
were compared for various application examples: ranking of different classes of adhesives, validated statistics of
adhesive-bonded joints using one particular adhesive and effects of cleaning and plasma-treatment on the adhesive
strength of coatings. The investigated systems included glass, metals and polymer substrates, different adhesives,
metallic and dielectric coatings on polymers.
Zur Bewertung der Klebkraft von Klebebändern werden üblicherweise die Prüfungen zur Bestimmung des Schälwiderstandes (in N/25 mm) mit 90° bzw. 180° Abzugswinkel unter Verwendung einer Zugprüfmaschine (ZP) herangezogen, Für die hier gezeigten Beispiele wurde dabei eine V2A-Prüfplatte (Ra = 0,15 pm), ein Abzugswinkel von 90° und eine Abzugsgeschwindigkeit von 300 mm/min verwendet.
Alternativ wurde der Versuch unternommen, die Klebkraft von Klebebändern durch die Prüfung der Verbundfestigkeit (in N/mm2) mittels Zentrifugen-Technologie (ZT) zu bestimmen. Dazu wurden beidseitig klebende Klebeband-Pads einer Abmessung von (10x10) mm2 zunächst auf V2A-Stahlsubstrate aufgebracht und anschließend dann auf diese modulare Prüfstempel (Klebfläche aus V2A, 0=10 mm; Massekörper
aus Cu) aufgesetzt. In Abb. 1 sind Beispiele von Versagensformen, wie sie nach der Prüfung der Verbundfestigkeit mittels ZT auftreten können, dargestellt.
Multiple-sample approach: reliable ranking and validated statistics of bonding and adhesive strength
(2014)
Bonding strength of adhesive-bonded joints and adhesive strength of coatings have been exclusively determined in single-sample tests using a tensile testing machine. Necessarily, the single-sample approach was also applied to the corresponding bonding procedure. As a consequence, reliability and reproducibility of results were restricted. By applying the newly introduced centrifuge technology, the multiple-sample approach was realized for simultaneous tensile testing of up to eight samples under identical conditions without any disturbing shear-force effects. In order to introduce the multiple-sample approach into the bonding procedure, a hydraulic bonding set-up was developed which enables identical bonding pressure also for slightly different heights of sample assemblies. Both sample approaches were compared for various application examples: ranking of different classes of adhesives, validated statistics of adhesive-bonded joints using one particular adhesive and effects of cleaning and plasma-treatment on the adhesive strength of coatings. The investigated systems included glass, metals and polymer substrates, different adhesives, metallic and dielectric coatings on polymers.
Zinkschichten wurden mit den zerstörungsfreien Methoden Röntgenfluoreszenz (XRF), mechanischer Tastschnitt (MS), Röntgenbeugung (XRD) und instrumentierter Eindringprüfung (IIT) hinsichtlich der makroskopischen und mikroskopischen Schichteigenschaften untersucht. Die Rauheit der Zinkschichten hängt im Wesentlichen von der Substratoberfläche ab. Inhomogenen Schichtdickenverteilung treten bekanntermaßen am Rand von Beschichtungsgestellen auf. Die plasto-elastische Eigenschaften Härte, E-Modul und Kriechen sind bei unterschiedlichen Abscheidungen vergleich- und reproduzierbar. Diese makroskopischen Schichteigenschaften sind geprägt von der Mikrostruktur der Schicht, die eine Vorzugsorientierung der Kristallite in der Netzebene (110), die senkrecht zur Substratoberfläche steht, zeigt.
The future commercial prospects for adhesive tapes are very good and its application range is very broad. From every-day-use in office, packaging, maintenance, and quick repair in workshops, it ranges from handicraft work, medical purposes and cosmetics up to workmanship. The study describes a new multi-sample approach in adhesive tape testing from theoretical background, preparation of test specimen for tensile as well as shear testing, detailed measurement procedures up to analysis and result interpretation. Various types of single and double-sided pressure sensitive adhesive tapes supplied by different manufacturers were investigated and compared
Die Bestimmung der Haftfestigkeit von Lackierungen, Beschichtungen oder Klebungen ist wichtig für die Beurteilung von entsprechenden Fertigungsabläufen. Unter Verwendung einer neuen Zentrifugentechnik wurde jetzt ein neues Mehr-Proben-Konzept zur schnellen Validierung von Klebverbindungen entwickelt.
Polypropylen (PP) ist als Niedrigenergie-Polymer ohne nass- und plasmachemische Vorbehandlung weder haftfest zu beschichten noch verbundfest zu kleben. Typische Haft- bzw. Klebfestigkeiten liegen für die unbehandelte Polymeroberfläche bei maximal 0,5 MPa. Hinzu kommt, dass bei der Bestimmung von Haft- und Klebfestigkeiten der unmodifizierten Oberfläche mit großen Streuungen zu rechnen ist, die bezogen auf die Spannweite durchaus einem Faktor 5 entsprechen können. Generell besteht bei Prüfung der Haftfestigkeit mittels Stirnabzugsversuch und bei der Prüfung der Klebfestigkeit die Notwendigkeit eines statistisch validierten Herangehens. Hierzu sind zeitaufwändige Ein-Proben-Klebungen und -Prüfungen nur eingeschränkt geeignet. Zudem ist, insbesondere für geringe Haft- bzw. Klebfestigkeiten, ein querkraftfreies Prüfen Grundvoraussetzung. Im vorliegenden Beitrag werden verschiedenartige plasmagestützte Oberflächenfunktionalisierungen von PP sowie das Mehr-Proben-Konzept zur Klebung/Prüfung von bis zu acht Proben vorgestellt. Dazu werden ein BAM-Funktionsmuster einer Mehr-Proben-Kleb-Vorrichtung und eine kommerzielle analytische Zentrifuge zum Prüfen verwendet.
Für Prüfungen in der Beanspruchung auf Zug zur Bestimmung der Haft- bzw. Klebfestigkeit bzw. in der Beanspruchung auf Druck zur Bestimmung der Härte wurden bisher Zug- bzw. Härteprüfmaschinen als Ein-Proben-Prüfungen verwendet. In der Beanspruchung auf Zug ist die Probe beidseitig, und um das Einleiten von Querkräften zu verhindern, oft doppeltkardanisch einzuspannen. In jedem Falle handelt es sich um Ein-Proben-Prüfungen. Bei der Zentrifugentechnologie kann mit der Zentrifugalkraft als Prüfkraft unter Verwendung eines Trommelrotors erstmals in einer Mehr-Proben- Anordnung gearbeitet werden. Da die Proben nur einseitig unterstützt werden, ist die Beladung über einfaches Einstecken realisierbar.
Mit dem Auf-Tisch-Prüfsystem können bis zu acht Proben gleichzeitig auf Zug oder Druck beansprucht werden. Ein aufgeklebter oder anderweitig mit dem Prüfkörper verbundener und unter Einwirkung der Zentrifugalkraft in einer Führungshülse radial nach außen laufender Prüfstempel beansprucht dann die Klebung, die Beschichtung oder den Verbund auf Zug bis zum Versagen. Im Augenblick des Abrisses wird ein positionscodiertes und drehzahlkorreliertes Signal gesendet und so die Bestimmung von Kleb-, Haft- bzw. Verbundfestigkeiten im Mehr-Proben-Versuch möglich. Analog beansprucht ein in einer Führungshülse radial innen an den Proben anliegender ggf. mit entsprechenden Eindringkörpern ausgerüsteter nach außen gerichteter Prüfstempel die Proben auf Druck.
Aus Drehzahl, Radius und Prüfstempelmasse können dann Kleb-, Haft- bzw, Verbundfestigkeiten oder aber Brinell-, Kugeldruck- oder Vickers-Härtewerte bestimmt werden.
Mit der Zentrifugentechnologie ist seit einigen Jahren ein neuartiges Mehr-Proben-Prüf-verfahren auf dem Markt etabliert, welches die klassische Zugprüfung in den Trommelrotor einer Tischzentrifuge überträgt. In der Beanspruchung auf Zug ist die Prüfung der Verbundfestigkeit seit 2017 nach DIN EN ISO/IEC 17025 akkreditiert, wobei die Verbundfestigkeit von Klebungen direkt bestimmt wird und in Abhängigkeit von den Versagensformen Rückschlüsse auf die Klebfestigkeit von Klebstoffen/Klebebändern oder die Haftfestigkeit von Beschichtungen gezogen werden können.
Bei der zerstörenden Beanspruchung auf Zug ist zu beachten, dass es sich bei der Verbundfestigkeit um eine Systemeigenschaft handelt, d.h. nicht nur die chemischen und topografischen Oberflächeneigenschaften, sondern auch die plasto-elastischen Volumeneigenschaften des Klebstoffes und der Fügeteile haben Einfluss auf die ermittelten Kennwerte. Dabei ist eine qualitative Bestimmung der Versagensformen und Bruchbilder nach DIN EN ISO 10365 zwingend erforderlich, um eine Aussage über die Art des Versagens treffen zu können.
Mit der Erweiterung der Zentrifugentechnologie um Beanspruchungen auf Druck wurde dann der Nachweis erbracht, dass auch die klassische Härteprüfung in einer Zentrifuge als Mehr-Proben-Prüfung durchgeführt werden kann. Im Verbundvorhaben QUO VADIS PLUS werden derzeit invasive Beanspruchungen auf Druck zur Bestimmung der Härte von Materialien, der Kompressibilität von Metallschäumen sowie der Kompaktierbarkeit von Pulvern untersucht, was das Anwendungspotential der Zentrifugentechnologie nochmals erweitert. Dazu gehören auch kombinierte Beanspruchungen wie Zug-Scher- und Druck-Scher-Prüfungen.
Die Verbundfestigkeit von CFK-Platten in Abhängigkeit der Beanspruchungsart (Zug vs. Zug-Scher) bzw. der Faserorientierung (0°, 45°, 90°), die Klebfestigkeit von Klebstoffen bzw. Klebebändern auf unterschiedlichen Fügeteilwerkstoffen in Abhängigkeit von der Vorbehandlung, die Haftfestigkeit optischer Schichten auf Kunststoffen, die Bestimmung der Vickers-, Brinell- bzw. Kugeldruck-Härte sowie die Kompressibilität von metallischen Schäumen und Federn werden als ausgewählte Beispiele diskutiert.
Phage display biopanning with Illumina next-generation sequencing (NGS) is applied to reveal insights into peptide-based adhesion domains for polypropylene (PP). One biopanning round followed by NGS selects robust PP-binding peptides that are not evident by Sanger sequencing. NGS provides a significant statistical base that enables motif analysis, statistics on positional residue depletion/enrichment, and data analysis to suppress false-positive sequences from amplification bias. The selected sequences are employed as water-based primers for PP-metal adhesion to condition PP surfaces and increase adhesive strength by 100% relative to nonprimed PP.