- nein (6)
Vehicle fires in tunnels can have catastrophic consequences for the road users, the property and traffic inffastructure. To support an evacuation planning, this study simulates the fire smoke toxicity and the smoke layer of a vehicle fire in a full-size test tunnel. The three dimensional prediction of the fire smoke toxicity in the test tunnel is realized by implementing the Fractional Effective Dose and the Fractional Summation concept in a CFD environment. The developed model facilitates to calculate fire scenarios for various types of tunnels and to quantify the hazard e.g. during an evacuation scenario.
Im Rahmen der schutzzielorientierten Brandschutzbemessung müssen, neben dem Nachweis der Wirksamkeit von Schutzmaßnahmen, Nachweise zur Einhaltung von in Abhängigkeit des Sicherheitsniveaus festgelegter Grenzwerte für die zulässige Wärmestrahlung, die Temperatur der oberen und unteren Rauchschicht, die toxische Konzentration von Rauchgasen und die Mindestsichtweite zum Schutz von Personen im Bauwerk erbracht werden.
Numerische Untersuchung sicherheitsrelevanter Grenzwerte zum Schutz von Personen im Brandfall
(2013)
Fire smoke contains a variety of highly toxic substances and can lead to unconsciousness within a few minutes and to death for critical concentrations. Currently the engineer’s methods of fire safety include various procedures to calculate the fire propagation and smoke spread in buildings.
However, up to now the evaluation and calculation of smoke concerning its optical properties and toxic potential on the basis of a detailed combustion is still a field of research. Since smoke composition is highly variable and not fully characterised it has to be examined whether and how the Chemical composition and the optical properties of smoke are correlating. A method has been developed that establishes the relation between the smoke components and smoke toxicity.