Filtern
Dokumenttyp
- Posterpräsentation (7)
- Zeitschriftenartikel (6)
- Vortrag (2)
- Dissertation (1)
Sprache
- Englisch (16)
Schlagworte
- Imaging (8)
- Coded apertures (4)
- X-ray (4)
- X-ray spectroscopy (4)
- Coded Apertures (3)
- Fluorescence (3)
- Spectroscopy (3)
- Synchrotron (3)
- X-ray fluorescence spectroscopy (3)
- Coded aperture (2)
Organisationseinheit der BAM
- 6 Materialchemie (15)
- 6.3 Strukturanalytik (15)
- 8 Zerstörungsfreie Prüfung (1)
- 8.5 Röntgenbildgebung (1)
Eingeladener Vortrag
- nein (2)
The present study investigates early stages of ZIF-8 crystallization up to 5 minutes post mixing of precursor solutions. Dispersive X-ray Absorption Spectroscopy (DXAS) provides a refined understanding of the evolution of the coordination environment during ZIF-8 crystallization. Linear Combination Fiting (LCF) suggests tetrakis(1-methylimidazole)zinc2+ to be a suitable and stable mononuclear structure analogue for some early stage ZIF-8 intermediates. Our results pave the way for more detailed studies on physico-chemical aspects of ZIF-8 crystallization to better control tailoring ZIF-8 materials for specific applications.
With increasing demand and environmental concerns, researchers are exploring new materials that can perform as well or better than traditional materials while reducing environmental impact. The BAMline, a real-life sample materials research beamline, provides unique insights into materials’ electronic and chemical structure at different time and length scales. The beamline specializes in x-ray absorption spectroscopy, x-ray fluorescence spectroscopy, and tomography experiments. This enables real-time optimization of material properties and performance for various applications, such as energy transfer, energy storage, catalysis, and corrosion resistance. This paper gives an overview of the analytical methods and sample environments of the BAMline, which cover non-destructive testing experiments in materials science, chemistry, biology, medicine, and cultural heritage. We also present our own synthesis methods, processes, and equipment developed specifically for the BAMline, and we give examples of synthesized materials and their potential applications. Finally, this article discusses the future perspectives of the BAMline and its potential for further advances in sustainable materials research.
We developed a setup for time- and lateral-resolved X-ray absorption fine structure (XAFS) spectroscopy. A dispersive element is placed behind the sample to investigate. The broadband incoming beam transmits the sample, is then dispersed and finally collected by a position sensitive detector. This allows the recording of a whole X-ray absorption near edge structure (XANES) or extended X-ray absorption fine structure (EXAFS) spectrum in a single shot. The dispersive element is a Si(111) crystal, bent by means of a so called wafer bender, developed in house. Our setup is very flexible, easy to adjust and allows a time resolution down to one second which can be used to follow chemical reactions with dynamics on this time scale.
Our aim is to develop a new method for full field X ray fluorescence imaging at the BAM line @ BESSY II. We will combine an energydispersive array detector for X rays with a coded aperture to get high resolution images . In coded aperture imaging , an object is projected through a mask , producing many overlapping images on the detector . The first part of the project is to perform raytracing simulations to get realistic data and to develop a reconstruction method that allows to get the Information about the investigated object out of the projected image .
Our aim is to develop a simple and inexpensive method for full field X-ray fluorescence imaging.We combine an energy-dispersive array detector with a coded aperture to obtain high resolution images. To obtain the information from the recorded image a reconstruction step is necessary. The reconstruction methods we have developed, were tested on simulated data and then applied to experimental data. The first tests were carried out at the BAMline @ BESSY II. This method enables the simultaneous detection of multiple elements, which is important e.g. in the field of catalysis.
One aim of this work was the development of a new setup for time- and laterally resolved XAFS measurements, based on the pronciple of dispersive XAFS. This setup is scanning free, stable, inexpensive, and straightforward to adjust for probing different elements. The second part of this work describes the impelemntation of a method for full-field X-ray fluorescence imaging with coded apertures. Expensive and complicated X-ray otpics, that are usually used for full-field imaging, are replaced with a coded aperture that consists of many pinholes drilled in an X-ray opaque material. Coded apertures are inexpensive to fabricate, energy independent and easy to use. The working principle is the same as with a pinhole camera, but the multiple holes allow a higher photon flux compared to a single pinhole or even a polycalippary optic, thus alowwing the reduction of measurement time.
We developed a new method for full field X-ray fluorescence imaging at the BAMline @ BESSY II. We combined an energy dispersive array detector for X-rays with a coded aperture to get high resolution images.
In coded aperture imaging, an object is projected through a mask, producing many overlapping images on the detector. To get the information about the investigated object out of the projected image, a decoding step is necessary.
The first part of our project was to develop the decoding algorithms. We tested the reported reconstruction with an antimask and compared the results with the performance of self-written reconstruction programs based on an iterative and a genetic algorithm. First tests were performed with raytracing simulations.
The next step was the collection of experimental data at the BAMline @ BESSY II (HZB). A test objects could be successfully reconstructed with our newly developed algorithm.
Our aim is to develop a new simple and inexpensive method for full field X-ray fluorescence imaging. We combine an energy-dispersive array detector with a coded aperture. To obtain the information from the recorded image, a reconstruction step is necessary. First tests were carried out at the BAMline at BESSY II. This method enables the simultaneous detection of multiple elements, which is important e.g. in the field of catalysis.
Our aim is to develop a new simple and inexpensive method for full field X-ray fluorescence imaging . We combine an energy dispersive array detector with a coded aperture to obtain high resolution images . To obtain the information from the recorded image a reconstruction step is necessary . The reconstruction methods we have developed , were tested on simulated data and then applied to experimental data . The first tests were carried out at the BAM line @ BESSY II. This method enables the simultaneous detection of multiple elements , which is important e.g. in the field of catalysis.
A newly developed EXAFS setup is presented. It enables both time- and spatially resolved EXAFS information simul-taneously in a single shot. First tests of this setup were performed at the BAMline @ BESSY-II (Berlin, Germany). A primary broadband beam generated by a filter/X-ray-mirror combination passes through the sample and is then dif-fracted by a convexly bent Si (111) crystal. This results in a divergent beam which is collected by an area sensitive detector, in a θ-2θ-geometry. Beside tests on metal foils the first in situ measurements were successfully carried out. The case-study deals with research on Zn-based Metal-Organic-Frameworks (MOF) with medical/pharmaceutical applications. This hot topic of MOFs research concerns drug delivery and encapsulation of therapeutically relevant proteins (e.g. BSA). Questions like how does a certain protein influences the coordination of Zn can be answered with this new setup. We were able to track structural changes within a 1s time resolution.