For the determination of safety characteristics of gases, vapors and dusts different types of ignition sources are used in international standards and guidelines. The paper presents test results of a comparative calorimetric and visual study between four different types of ignition sources. The ignition procedures were analyzed visually with a high-speed camera and electric recordings. In addition to that, the influence of the electrode-orientation, -distance as well as ignition energy on the reproducibility of the exploding wire igniter was tested.
The exploding wire is already in use for standardized determination of safety characteristics of gases, first tests on the suitability of the exploding wire igniter for dust testing have been carried out but are not standardized yet. Using the exploding wire, the ignition energy can be varied from 2 J to 10 000 J (2 x 5000 J) and thus it could be used for gases, vapors, dusts and hybrid mixtures. Moreover it can be used at high initial pressures and it is the only ignition source with an easily measurable ignition energy release. Furthermore, it does not introduce another chemical reaction into the system.
Finally, a proposal for a standard ignition source for explosion tests on hybrid mixtures is derived from the test results.
Several standardized ignition sources are used to determine the safety characteristics of gases, vapours and dusts. Standards indicate the source of ignition but vary in specifying other features such as the burning duration, energy or the volume in which the energy is released. Since heat is not visible under normal conditions, a schlieren technique was used to visualize the entire igniting volume and not just the flames. This article focuses on the igniting volume, compares it among the four standardized ignition sources and displays its relationship to the size of the test vessel. Differences in the ignition behaviour of the ignition sources might lead to the determination of erroneous safety characteristics and with that to the unsafe operation of processes.