Polypropylene based ferroelectret films exhibit a strong electromechanical activity and provide a promising solution for the air coupled ultrasonic (ACUS) transducers. Ultrasonic transmission between two air coupled ferroelectret transducers in dependence on the amplitude and polarity of the high voltage exciting pulse revealed a strongly non-linear electromechanical response of the ferroelectret transmitter which provides an increase in the transmitter efficiency. The authors present a simple model describing both promotion and competition of the piezoelectric and electrostriction contributions, as well as increase in the transducer constant under high voltage excitation. Enlargement of the inverse transducer constant of the polypropylene ferroelectret film by a factor of 4 was demonstrated. The non-linear properties of the polypropylene ferroelectrets result in a strong increase in their ACUS figure of merit under the high voltage excitation, which exceeds the results of their technological optimisation. Consequently, enhancement of the ACUS system transmission by 12 dB and signal to noise ratio by 32 dB was achieved.
Ferroelectrets are promising materials for air-coupled ultrasonic transducers. A transducer made of polarized cellular polypropylene, including its electronic interface, was developed and compared with conventional air-coupled probes. Test pieces of fiber-reinforced polymer containing impact flaws and flat-bottom holes were inspected in transmission. The ferroelectret transducers achieved a considerably higher signal-to-noise ratio. The impacts were clearly visible with all transducers, but less noisy with ferroelectret transducers. The flat-bottom holes were better detectable than with a conventional probe with about the same focus size.
Ultrasonic examination of anisotropic inhomogeneous austenitic welds is challenging, because of the columnar grain structure of the weld leads to beam skewing and splitting. Modeling tools play an important role in understanding the ultrasound field propagation and optimization of experimental parameters during the ultrasonic testing of austenitic welds as well as the interpretation of the test results. In this contribution, an efficient theoretical model based on the ray tracing concepts is developed to calculate the ultrasonic fields in inhomogeneous austenitic welds quantitatively. The developed model determines the ultrasound fields by taking into account the directivity of the ray source, the inhomogenity of the weld as well as ray transmission coefficients. Directivity of the ray source in columnar grained austenitic materials (including layback orientation) is obtained in three dimensions based on Lamb's reciprocity theorem. Ray energy reflection and transmission coefficients at an interface between two general columnar grained austenitic materials are calculated in three dimensions. The ray tracing model predictions on inhomogeneous austenitic weld material are compared against those from CIVA, a commercial non-destructive modeling and simulation tool. The ultrasonic modeling tools in CIVA are based on semi-analytical solutions. For beam propagation simulation, a so-called 'pencil method' is used, which involves modeling the probe as a set of individual source points, each radiating 'a bundle' of diverging rays into the medium and integrating those elementary contributions. Inhomogenity in the weld region is approximated by mapping the grain orientations on weld macrograph. Simulation results for ultrasonic field profiles for an austenitic weld are shown to be in good agreement with the corresponding experimental results.
Für die luftgekoppelte Ultraschall-Prüfung wird der Prototyp eines neuartigen Prüfkopfes vorgestellt. Statt eines piezokeramischen Ultraschall-Wandlers mit einer λ/4-Anpassschicht wird eine Ferroelektret-Folie aus schaumförmigem Polypropylen eingesetzt. Durch die außerordentlich geringe akustische Impedanz der Folie reduzieren sich die Reflexionsverluste an den Grenzschichten zur Luft so stark, dass bei diesem Prüfkopf auf eine λ/4-Anpassschicht verzichtet werden kann. Außerdem ist die Folie hochspannungsfest. Sie konnte mit Spannungen von mehr als 3500 V angesteuert werden und erlaubte eine Vorspannung am Ultraschall-Wandler des Empfangsprüfkopfes von 2000 V. Mithilfe der hohen Anregungsspannung stieg die Amplitude des akustischen Prüfimpulses auf das 11,2-Fache. Die Empfindlichkeit des Empfängers erhöhte sich durch die Vorspannung weiter um den Faktor 4,3. Insgesamt steigt die Amplitude am Empfänger also auf das 48-Fache, bei gleichbleibendem Rauschpegel. Ein abschließender Vergleich mit kommerziellen Luftultraschall-Prüfköpfen belegt die Überlegenheit der Folien-Prüfköpfe. Damit rückt der Einsatz einer vollwertigen Impuls-Echo-Technik auch bei der luftgekoppelten Ultraschallprüfung deutlich näher.
In this contribution we present a novel thermo-acoustic approach for the generation of broad band airborne ultrasound and investigate the applicability of resonance-free thermo-acoustic emitters for very short high pressure airborne ultrasound pulses. We report on measurements of thermo-acoustic emitter consisting of a 30 nm thin metallic film on a usual soda-lime glass substrate, generating sound pressure values of more than 140 dB at 60 mm distance from the transducer and compare the results with conventional piezoelectric airborne ultrasound transducers. Our experimental investigations show that such thermo-acoustic devices can be used as broad band emitters using pulse excitation.
Defect sizing is required for a quantitative assessment of the quality and reliability of safety relevant components and materials using ultrasonic non-destructive testing. The SAFT (Synthetic Aperture Focussing Technique) and the TOFD technique (Time Of Flight Diffraction) are such promising sizing candidates, extracting more information from the raw ultrasound echo data and the corresponding crack tip response. In this work the phased array technique is used to inspect a clad mock-up model of a pressure vessel section. The full scale model contains artificial test reflectors which are located in the weld and in the cladding region as well. The defects—representing typical flaws at a very early stage—are analysed with different frequencies, beam angles and directions of incidence.
For the reconstruction of reflector indications a SAFT algorithm is applied to the phased array measurement results. Additionally the reflectors are analysed by means of the TOFD technique, using different beam angles at the same time. Both analysis methods are performed using different directions of incidence considering the complex cladding structure underneath the inner surface of the mock-up model. A direct comparison of the SAFT and TOFD techniques shows that, besides the clarity of the results, the detection and sizing capabilities of SAFT are far better.
We present a generalized analytical model of thermo-acoustic sound generation based on the analysis of thermally induced energy density fluctuations and their propagation into the adjacent matter. The model provides exact analytical prediction of the sound pressure generated in fluids and solids; consequently, it can be applied to arbitrary thermal power sources such as thermophones, plasma firings, laser beams, and chemical reactions. Unlike existing approaches, our description also includes acoustic near-field effects and sound-field attenuation. Analytical results are compared with measurements of sound pressures generated by thermo-acoustic transducers in air for frequencies up to 1 MHz. The tested transducers consist of titanium and indium tin oxide coatings on quartz glass and polycarbonate substrates. The model reveals that thermo-acoustic efficiency increases linearly with the supplied thermal power and quadratically with thermal excitation frequency. Comparison of the efficiency of our thermo-acoustic transducers with those of piezoelectric-based airborne ultrasound transducers using impulse excitation showed comparable sound pressure values. The present results show that thermo-acoustic transducers can be applied as broadband, non-resonant, high-performance ultrasound sources.
NDT is a multidisciplinary research area fusing the disciplines of natural Science and engineering. Particularly in the early development stages of a new testing method, feasibility investigations focus on the fundamental physical interaction between the sensing mechanism and specimen. Research activities during subsequent phases of modular prototype development, technical System Integration and Validation primarily attempt to solve the practical engineering and real-life aspects of a testing method. We show several examples of new methods in different stages of development and highlight the potential for further industrial use. The first section deals with Steel surfaces of lightweight components which are
inspected with pm-sized magneto resistive sensor arrays. This quantitative magnetic stray field approach combines high spatial resolution and very high sensitivity, enabling the user to detect even very small micro-defects. Tuming to CFRP components we also show new developments in airbome ultrasonic testing. Here we use ferroelectret foils to reduce the acoustical mismatch between transducer and air, which enhances the signal-to-noise ratio. A further example illuminates the use of metallic nano layers as a broadband thermo acoustical emitter. Their use provides both high sound pressures and very broadband Signal characteristics. When it comes to CFRP components and other anisotropic and highly Scattering materials, ultrasonic matrix arrays in conjunction with many angles of incidences per transducer position can help to enhance the statistics of a testing problem. In the field of conventional water-coupled UT testing we also show the use of matrix array transducers
providing a tomographic-like 3D-image of impact damage in CFRP samples.