Filtern
Erscheinungsjahr
Dokumenttyp
- Beitrag zu einem Tagungsband (122)
- Zeitschriftenartikel (54)
- Vortrag (27)
- Beitrag zu einem Sammelband (20)
- Posterpräsentation (3)
- Buchkapitel (2)
- Sonstiges (1)
- Forschungsbericht (1)
Sprache
- Englisch (188)
- Deutsch (40)
- Mehrsprachig (1)
- Polnisch (1)
Schlagworte
- Structural health monitoring (27)
- OTDR (24)
- Distributed sensor (18)
- Strain sensor (18)
- Optical fiber sensor (17)
- Distributed fiber sensing (13)
- POF sensor (13)
- BOFDA (12)
- Distributed sensing (12)
- Distributed acoustic sensing (11)
Organisationseinheit der BAM
Eingeladener Vortrag
- nein (27)
Gamma radiation induced effects in perfluorinated polymer optical fibers for sensing applications
(2015)
Radiation induced attenuation in perfluorinated polymer optical fiber was investigated as a potential mean for online. in situ gamma radiation monitoring. Spectral dependence of radiation induced attenuation was measured in the visible and near infrared range. Attenuation spectrum exhibits sharp increase both towards the ultraviolet and infrared side of the spectrum with 3 distinct peaks around 1400 nm. The fiber sensitivity to gamma radiation was further evaluated at two commonly used IR wavelengths (1310nm and l550nm} by pre- and post-irradiation optical time-domain reflectometry measurements. The examined fiber is sensitive up to lOO kGy of total absorbed dose with only minor saturation towards the large dose values. The influence of gamma radiation on the fiber mechanical properties was studied as well. Up to the maximal dose of 100 kGy, no significant deterioration of fiber strength and elasticity was observed.
A systematic study of annealing behavior of drawn PMMA fibers was performed. Annealing Dynamics were investigated under different environmental conditions by fiber longitudinal shrinkage monitoring. The shrinkage process was found to follow a stretched exponential decay function revealing the heterogeneous nature of the underlying molecular dynamics. The complex dependence of the fiber shrinkage on initial degree of molecular alignment in the fiber, annealing time and temperature was investigated and interpreted. Moreover, humidity was shown to have a profound effect on the annealing process, which was not recognized previously. Annealing was also shown to have considerable effect on the fiber mechanical properties associated with the relaxation of molecular alignment in the fiber. The consequences of fiber annealing for the climatic stability of certain polymer optical fiber-based sensors are discussed, emphasizing the importance of fiber controlled pre-annealing with respect to the foreseeable
operating conditions.
We report on the successful application of distributed acoustic sensing (DAS) to the detection of partial discharge (PD). A detection limit of about 1 nC discharge magnitude was achieved for PD in a real-scale model of a high voltage termination. Dedicated ultrasonic fibre-optic transducers were interrogated using coherent optical time-domain Rayleigh backscatter reflectometry (C-OTDR). Random quadrature demodulation was employed for retrieving relevant acoustic information from the raw C-OTDR backscatter traces. To our knowledge, our results are a first-time demonstration that quasi-distributed fibre-optic acoustic sensing is a candidate technology for the acoustic partial discharge monitoring of power cable joints and terminations.
Systematic investigation of annealing behavior of drawn PMMA fibers was performed. Dynamics of annealing process were measured under different environmental conditions by fiber longitudinal shrinkage monitoring. Process was found to follow stretched exponential decay function indicating heterogeneous nature of underlying molecular dynamics. Consequences of fiber annealing for climatic stability of polymer optical fiber-based sensors are discussed, emphasizing importance of fiber controlled post-fabrication annealing. Dependence of induced fiber shrinkage on annealing time, temperature and fiber drawing conditions is investigated and interpreted. In addition, strong influence of humidity on annealing process was observed, which was not recognized in previous studies. This further highlights role of fiber post-fabrication thermal treatment with respect to intended operating conditions.
We report on the development of a distributed fiber optical sensor system for structural health monitoring of largc-scale geotechnical and civil infrastructures. The system is based on Brillouin frequency domain analysis (BOFDA) for distributed measurement of strain and temperature along Standard silica optical fibers used as sensors. By additional incorporation of the fiber optic sensors in geosynthetics, two-dimensional sensors can be realized. Such smart geosynthetics can be used for reinforeerneut of geotechnical and masonry structures and the embedded fiber optic sensors can provide information about the condition of the structures and detect the presence of any damages and destructions in real time.
In this work, the potential of fiber Bragg gratings (FBGs) in low-loss perfluorinated polymer optical fibers (PF-POFs) is explored. The FBG is femtosecond-inscribed in a commercial multi-mode (MM) PF-POF based on Cytop® polymer. Femtosecond inscription leads to creation of a highly saturated grating with a number of higher order reflection Peaks visible throughout the visible and near-infrared spectral region. For 2 mm long FBG having a pitch of 2.2895 μm, a total of nine higher-order MM reflection bands are visible spanning from 1548 nm (4th order) to 520 nm (12th order). Strain sensitivity was measured for 6 peak bands in 500-900 nm region, where relatively low cost CCD based spectrometers and broadband LEDs are available. Strain sensitivity increases almost linearly with increasing initial peak wavelength, growing from 4.82 ± 0.02 nm/% measured for 12th order peak at 517 nm to 8.12 ± 0.04 nm/% measured for 7th order peak at 883 nm. These values correspond to roughly 20 % higher sensitivity than silica FBGs exhibit in this spectral range. The gratings in PF-POFs combine the higher strain sensitivity and low-loss operation while maintaining the mechanical advantages of polymer optical fibers. Therefore, they hold a high potential for considerable broadening of polymer optical fiber Bragg gratings application range.
In this paper, we present the first results regarding the on-line monitoring of gamma-ray exposure effects on a commercial multi-mode perfluorinated polymer optical fiber (PF-POF), type GigaPOF-50SR from Chromis Fiberoptics. Our focus was to evaluate on-line the radiation induced attenuation (RIA) over a wide spectral range (320 nm – 1700 nm), in order to assess the fiber’s radiation hardness and its possible use in radiation detection. An Ocean Optics QE65000 high sensitivity spectrometer and a StellarNet near-IR spectrometer were used to cover the spectral ranges 200 nm – 1μm and 900 nm – 1.6 μm, respectively. Electron paramagnetic resonance was used to monitor the recovery of the irradiation induced centers at room temperature. The study indicated that the optical fiber can be used as radiation monitor at low dose rates by measuring the attenuation in the UV, while higher dose rates irradiation can be observed by RIA monitoring at specific wavelengths in the visible spectral range.
We describe the fabrication of a polycarbonate (PC) micro-structured polymer optical fiber (mPOF) and the writing of fiber Bragg gratings (FBGs) in it to enable strain and temperature measurements. We demonstrate the photosensitivity of a dopant-free PC fiber by grating inscription using a UV laser. We further show that PC Bragg gratings can be extended up to at least 3% without affecting the initial functionality of the micro-structured fiber. The response of PC FBGs to temperature up to 125°C is also investigated. Polycarbonate has good mechanical properties and its high temperatureresistance might extend the range of application of polymeric FBGs.