A novel quasi-distributed long-gauge fiber optic strain sensor system for dynamic measurement
(2011)
We present a novel technique based on incoherent optical frequency domain reflectometry (OFDR) to measure length changes quasi-distributed between reflection points in optical fibres. The technique enables length changes to be measured with a resolution better than 1 µm and allows for static and dynamic measurement capabilities up to 2 kHz. We demonstrate that dynamic measurements of multiple fibre sections can be conducted independently from each other with high precision. Due to the precise and dynamic measurement capabilities, the proposed sensor system is expected to open new fields of application, especially in the structural-health-monitoring sector. Possible applications are discussed in the paper.
A long period grating (LPG) mechanically imprinted in a microstructured polymer optical fibre (mPOF) is embedded in a carbon fibre reinforced polymer (CFRP) unidirectional laminate. Processing steps were established in order to ensure that mPOF does not suffer significant degradation. The strain and temperature responses of the embedded mPOF-LPG were then investigated.
For long-range measurements in geotechnical and industrial applications, distributed optical fiber sensors have become a tool of increasing importance throughout the past decade.
Classic deformation monitoring (performed by strain gauges etc.) and temperature monitoring (Pt100 and alike) deliver data from fixed, single spots of a structure; quasidistributed measurements (fiber bragg gratings) provide a Chain of discrete measurement points along a limited sensing length. In contrast, an opticai fiber connected to a device for distributed strain and temperature sensing (DTSS) will provide a continuous profile of strain and temperature - spatially resolved down to less than 1 m - over a ränge of several tens of kilometers.
In DTSS measurements, the nonlinear opticai effect of stimulated Brillouin Scattering (SBS) is employed: two light waves with a stable, tunable frequency offset are injected into opposite ends of the sensing fiber, where they will form a beat pattem, at which parts of the light will be scattered. By matching the frequency offset of the light waves to the propagation of acoustic fluctuation in the opticai fiber, a power transfer from one light wave to the other can be measured; since the acoustic propagation directly shifts with train and temperature of the fiber, these two quantities can be measured by tuning the light waves’ frequency offset.
Analytical model for ball-lensed couplers to calculate the insertion loss for each optical mode. The basis for the calculation are commercial perfluorinated polymer optical (PFGI-POFs) and silica based fibres (SOFs). The modal power distribution for given misalignments are presented as well as the reflection-based losses at all optical interfaces. Additionally, the ball-lensed interconnection between PFGI-POF and SOF was theoretically demonstrated.
Application of Intensity-Based Coherent Optical Time Domain Reflectometry to Bridge Monitoring
(2022)
Although distributed fiber sensing techniques have been widely used in structural health monitoring, the measurement results of bridge monitoring, particularly under destructive testing, have rarely been reported. To the best of our knowledge, this paper is the first report of distributed vibration measurement results, which we obtained during a three-day destructive test on an abolished bridge. A coherent optical time domain reflectometry (COTDR) was used to acquire the vibration information while the bridge was being sawed. The obtained signal was analyzed in time and frequency domain. Some characteristics of the sawing-induced vibration were retrieved by the short-time Fourier transform; the vibration exhibited several high frequency components within the measured range up to 20 kHz and all the components appeared in the same time slot. Some unexpected signals were also detected. Thorough analysis showed that they are quite different from the sawing-induced vibration and are believed to originate from internal damage to the bridge (probably the occurrence of cracks).
Application results of a dynamic technique for simultaneous measurement of length changes and optical power changes between multiple reflection points in an optical fiber are presented. The technique is based on incoherent optical frequency domain reflectometry (I-OFDR) and allows for measuring for example length changes and optical power changes quasi-distributed at repetition rates up to 2 kHz. Precise measurement with length change resolutions in the µm-range can be conducted using standard single-mode or multi-mode fibers. Previous results of dynamic refractive index change measurement and the use of polymer optical fibers for high-strain measurement are concluded and possible sources of measurement inaccuracies are discussed. Field test results with sensors installed on a masonry building during a seismic shake test are presented. The versatility and simplicity of this technique makes it potentially interesting for application in the structural health monitoring sector and chemical process control.