In this work, the potential of fiber Bragg gratings (FBGs) in low-loss perfluorinated polymer optical fibers (PF-POFs) is explored. The FBG is femtosecond-inscribed in a commercial multi-mode (MM) PF-POF based on Cytop® polymer. Femtosecond inscription leads to creation of a highly saturated grating with a number of higher order reflection Peaks visible throughout the visible and near-infrared spectral region. For 2 mm long FBG having a pitch of 2.2895 μm, a total of nine higher-order MM reflection bands are visible spanning from 1548 nm (4th order) to 520 nm (12th order). Strain sensitivity was measured for 6 peak bands in 500-900 nm region, where relatively low cost CCD based spectrometers and broadband LEDs are available. Strain sensitivity increases almost linearly with increasing initial peak wavelength, growing from 4.82 ± 0.02 nm/% measured for 12th order peak at 517 nm to 8.12 ± 0.04 nm/% measured for 7th order peak at 883 nm. These values correspond to roughly 20 % higher sensitivity than silica FBGs exhibit in this spectral range. The gratings in PF-POFs combine the higher strain sensitivity and low-loss operation while maintaining the mechanical advantages of polymer optical fibers. Therefore, they hold a high potential for considerable broadening of polymer optical fiber Bragg gratings application range.
Die Eignung von Faser-Bragg-Gitter-(FBG)-Sensoren zur Messung ionisierender Strahlung wurde an einem Undulator des Elektronenspeicherrings BESSY II untersucht. Über einen Zeitraum von 20 Wochen wurde eine durch Strahlung verursachte Bragg-Wellenlängenänderung der FBG-Sensoren von 25pm gemessen, was einer Strahlendosis von 720 Gy entspricht.
The suitability of using fiber Bragg grating (FBG) sensors for the measurement of ionizing radiation on the electron storage ring BESSY II by measuring the Bragg wavelength shift caused by radiation was investigated. During a time period of 20 weeks a Bragg wavelength shift of 25pm caused by the ionizing radiation was measured by FBG sensors at the storage ring. This Bragg wavelength shift corresponds to a radiation dose value of 720 Gy.
The potential impact of optical fiber sensors embedded into medical textiles for the monitoring of respiratory movements in a magnetic resonance imaging environment is presented. We report on three different designs, all textile based: a macrobending sensor, a Bragg grating sensor, and a time reflectometry sensor. In all three cases, the sensing principle is based on the measure of the elongation of the abdominal circumference during breathing movements. We demonstrate that the three sensors can successfully sense textile elongations between 0% and 3%, while maintaining the stretching properties of the textile substrates for a good comfort of the patients.
A systematic study of annealing behavior of drawn PMMA fibers was performed. Annealing Dynamics were investigated under different environmental conditions by fiber longitudinal shrinkage monitoring. The shrinkage process was found to follow a stretched exponential decay function revealing the heterogeneous nature of the underlying molecular dynamics. The complex dependence of the fiber shrinkage on initial degree of molecular alignment in the fiber, annealing time and temperature was investigated and interpreted. Moreover, humidity was shown to have a profound effect on the annealing process, which was not recognized previously. Annealing was also shown to have considerable effect on the fiber mechanical properties associated with the relaxation of molecular alignment in the fiber. The consequences of fiber annealing for the climatic stability of certain polymer optical fiber-based sensors are discussed, emphasizing the importance of fiber controlled pre-annealing with respect to the foreseeable
operating conditions.
For patients under Magnetic Resonance Imaging (MRI) spontaneous respiration is constantly at risk of being impaired by anesthetic drugs or by upper airway obstruction. Therefore, continuous monitoring of the breathing activity is needed to assess adequate ventilation or to detect specific obstruction patterns. The paper describes three MRI compatible respiration sensors based on pure optical technologies developed within the EU FP6 project OFSETH. The sensors are based on fiber Bragg gratings, optical time-domain reflectometry and macrobending effects. The developed smart medical textiles can sense elongation up to 3% while maintaining the stretching properties of the textile substrates for patient's comfort. The OFSETH harness allows a continuous measurement of abdominal and thoracic respiration movement while all vitals organs are free for medical staff actions. The sensors were tested in MRI environment and on healthy adults.
Strain sensors used for structural health monitoring (SHM) must provide reliable measurement data during their entire service lifetime. To achieve this for fibre optic sensors integrated into composites, the integration of the sensor has to be adapted according to the process conditions. This paper describes the fabrication of thermoplastic composite samples with integrated distributed fibre optic sensors (DFOS) based on copper-nickel and polyimide coated silica optical fibres. The performance of these DFOS as SHM sensors is evaluated in terms of reliability by measurements derived from comparative measurements with resistance strain gauges and from fatigue tests with 10 million load cycles.
The paper presents the first complex study of Gamma radiation effects on a low-loss perfluorinated polymer optical fiber (PF-POF) based on Cytop® polymer. Influence of gamma radiation on fiber’s optical, mechanical and climatic performance is investigated. The radiation-induced attenuation (RIA) in the visible and near-infrared region (0.4 μm-1.7 mm) is measured and its origins are discussed. Besides attenuation increase, radiation is also shown to decrease the thermal degradation stability of the fiber and to increase its susceptibility to water. With regard to complex fiber transmission performance upon irradiation, the optimal operation wavelength region of PF-POF-based systems intended for use in Radiation environments is determined to be around 1.1 μm. On the other hand, the investigated fiber holds potential for low-cost RIA-based optical fiber dosimetry applications with sensitivity as high as 260 dBm⁻¹/kGy in the visible region.
Distributed fiber optic sensors for structural health monitoring of composite pressure vessels
(2024)
In diesem Beitrag geben wir einen umfassenden Überblick über unsere Forschung auf dem Gebiet der verteilten faseroptischen Sensorik für die strukturelle Zustandsüberwachung von Wasserstoffdruckbehältern aus Verbundwerkstoffen. Insbesondere zeigen wir, wie die Integration von faseroptischen Sensoren in Druckbehälter aus Verbundwerkstoffen die Sicherheit erhöht und gleichzeitig die Wartungskosten senkt. Die geringe Größe von Lichtwellenleitern ermöglicht ihre Integration in Verbundwerkstoffstrukturen während des Herstellungsprozesses, wodurch eine kontinuierliche Überwachung sowie eine präzise Erkennung und Lokalisierung von Strukturschäden während des Betriebs der Druckbehälter ermöglicht wird. Wir erörtern auch das Potenzial modernster Signalverarbeitungsmethoden und des maschinellen Lernens für die Weiterentwicklung der vorausschauenden Instandhaltung. Die von uns vorgestellten Anwendungen von faseroptischen Sensoren zeigen, dass sie einen wichtigen Beitrag zur Energiewende hin zu erneuerbaren Energien leisten können.
Application of Intensity-Based Coherent Optical Time Domain Reflectometry to Bridge Monitoring
(2022)
Although distributed fiber sensing techniques have been widely used in structural health monitoring, the measurement results of bridge monitoring, particularly under destructive testing, have rarely been reported. To the best of our knowledge, this paper is the first report of distributed vibration measurement results, which we obtained during a three-day destructive test on an abolished bridge. A coherent optical time domain reflectometry (COTDR) was used to acquire the vibration information while the bridge was being sawed. The obtained signal was analyzed in time and frequency domain. Some characteristics of the sawing-induced vibration were retrieved by the short-time Fourier transform; the vibration exhibited several high frequency components within the measured range up to 20 kHz and all the components appeared in the same time slot. Some unexpected signals were also detected. Thorough analysis showed that they are quite different from the sawing-induced vibration and are believed to originate from internal damage to the bridge (probably the occurrence of cracks).