Filtern
Erscheinungsjahr
Dokumenttyp
- Zeitschriftenartikel (29)
- Beitrag zu einem Tagungsband (25)
- Buchkapitel (1)
- Vortrag (1)
- Posterpräsentation (1)
- Forschungsbericht (1)
Schlagworte
- Dust explosion (6)
- Dust explosions (5)
- Hybrid mixtures (5)
- CFD (4)
- Dustiness (4)
- Explosion protection (3)
- Explosionsschutz (3)
- Lower explosion limit (3)
- Safety characteristics (3)
- Venting (3)
Organisationseinheit der BAM
Paper des Monats
- ja (2)
Eingeladener Vortrag
- nein (1)
Quasi-static dispersion of dusts for the determination of lower explosion limits of hybrid mixtures
(2022)
Knowledge of explosion limiting concentration of explosible materials is necessary forthe design of explosion protection measures. Currently employed methods of testing MEC of a dust cloud or LEL of a hybrid mixture are based on arbitrary assumptionsand possess technical limitations that often lead to values of MEC/LEL, which are unrealistically low or poorly reproducible. This contribution presents an improved method for experimental determination of MEC of a combustible dust cloud or LEL of a flammable gas or hybrid mixture. The new setup operates under laminar conditions and allows a uniform suspension of dust particles in an open top acrylic glass tube. Dust concentration is measured with the help of infrared sensors installed a few centimeters above and below the ignition source. In order to evaluate the dependence of MEC on flow front velocity, MEC of lycopodium was determined at four flow velocities. The results show that the flow field intensity does not significantly influence the MEC of lycopodium for the flow ranges tested in this work. Moreover, LEL of hybrid mixtures of lycopodium and methane was also tested at flow velocities of 4.7 cm/s, 5.8 cm/s, 7 cm/s and 11 cm/s and compared with the values obtained from other sources. The results suggest that the requirement of high energy pyrotechnical igniter may be relinquished, provided that a truly homogeneous suspension of dust particles could be achieved. Moreover, the effect of relative amount of dust and gas, on the course of ignition and flame propagation in hybrid mixtures at their LEL, was studied by the help of high speed videos. For hybrid mixtures of carbonaceous dusts (like lycopodium) at their LEL, ignition occurs in the gas phase, however, flame propagation is only possible through a two-way interaction of dust and gas during the course of combustion.
In this study, 19 experiments were conducted with 25 pouch cells of NMC cathode to investigate thermal runaway and the release of gases from lithium-ion batteries (LIBs). Single cells, double cells, and a four-cell battery stack were forced to undergo thermal runaway inside an air-tight reactor vessel with a volume of 100 dm3 . The study involved two series of tests with two types of ignition sources. In the Series 1 tests, a heating plug was used to initiate thermal runaway in LIBs in the ranges of 80–89% and 90–100% SOC. In the Series 2 tests, a heating plate was used to trigger thermal runaway in LIBs in the ranges of 30–50%, 80–89%, and 90–100% SOC. Thermal runaway started at an onset temperature of 344 ± 5 K and 345 K for the Series 1 tests and from 393 ± 36 K to 487 ± 10 K for the Series 2 tests. Peak reaction temperatures ranged between 642 K and 1184 K, while the maximum pressures observed were between 1.2 bar and 7.28 bar. Thermal runaway induced explosion of the cells and lead to a rate of temperature increase greater than 10 K/s. The amounts of gases released from the LIBs were calculated from pressures and temperatures measured in the reactor.
Then, the gas composition was analyzed using a Fourier transform infrared (FTIR) spectrometer. The highest gaseous production was achieved at a range of 90–100% SOC and higher battery capacities 72 L, 1.8 L/Ah (Series 1, battery stack) and 103 L, 3.2 L/Ah (Series 2, 32 Ah cell)). Among the gases analyzed, the concentration of gaseous emissions such as C2H4 , CH4 , and C2H6 increased at a higher cell capacity in both series of tests. The study results revealed characteristic variations of thermal behavior with respect to the type of ignition source used.
Composition and Explosibility of Gas Emissions from Lithium-Ion Batteries Undergoing Thermal Runaway
(2023)
Lithium-based batteries have the potential to undergo thermal runaway (TR), during which mixtures of gases are released. The purpose of this study was to assess the explosibility of the gaseous emission from LIBs of an NMC-based cathode during thermal runaway. In the current project, a series of pouch lithium-based battery cells was exposed to abuse conditions (thermal) to study the total amount of gases released and the composition of the gas mixture. First, the battery cells were placed in a closed vessel, and the pressure and temperature rise inside the vessel were measured. In a second step, the composition of gases was analysed using a Fourier transform Infrared (FTIR) spectrometer.
We found that the amount of released gases was up to 102 ± 4 L, with a clear dependence on the battery capacity. This study showed that the concentration of gaseous emissions such as carbon monoxide (CO), methane (CH4), ethylene (C2H4), ethane (C2H6), and hydrogen cyanide (HCN) increased with higher cell capacity. Of the five studied flammable gases, the maximum concentrations of carbon monoxide (16.85 vol%), methane (7.6 vol%), and ethylene (7.86 vol%) were identified to be within their explosible range. Applying Le Chatelier’s law, a calculated lower explosion limit (LEL) of 7% in volume fraction was obtained for the gas mixture. The upper explosion limit (UEL) of the gas mixture was also found to be 31% in volume. A filter comprising pyrobubbles was used for the removal of the studied gas components released during the thermal abuse. The investigation revealed that the pyrobubbles filter was highly effect in the removal of HCN (up to 94% removal) and CO2 (up to 100% removal). Herein, we report the dependency of the method of thermal runaway trigger on the measured maximum temperature.
Lithium ion batteries (LIBs) are prone to spontaneous and subsequent fire or explosion resulting from thermal runaway. The vented gases are not only toxic and flammable, their emission can also raise the surrounding pressure rapidly. In this study, characteristic variations of explosion pressure rise, rate of explosion pressure rise and 𝐾(sT)-value have been evaluated. The characteristic 𝐾(𝑠𝑇)-values were determined to evaluate the explosive behavior of LIBs during thermal runaway. The estimated values were compared to that of other explosive substances.
Filter criteria in the Frame of Fire PSA identify compartments in a first qualitative analysis for which the contribution to the overall core damage frequency of the NPP is negligible. The aim of the filter criteria is to reduce the number of compartments to be analysed precisely in Fire PSA. One example for filter criteria is the 'fire load criterion'. By the fire load criterion compartments with a fire load density of less than 90 MJ/m² are 'screened out' which means to exclude them from a precise analysis in Fire PSA. Neither the justification of the particular value of 90 MJ/m² is well documented nor does this criterion take into account varying compartment configurations such as ventilation conditions, physical and chemical properties of the fire load as well as compartment characteristics.
A probabilistic set of filter criteria was developed to overcome the restrictions of the fire load criterion. In line with the 'fire load criterion', the probabilistic set of filter criteria assumes that a compartment can be screened out if a fire is not able to cause any damage to other components within the compartment. Therefore, the electrical failure of an electrical cable conservatively represents the damages of all components. It is assumed that the electrical cable failure occurs when the maximum cable temperature exceeds an experimentally determined failure temperature. The maximum cable temperature that can occur in a compartment fire is mainly influenced by the four significant factors: 1. inlet air stream of the mechanical ventilation, 2. the fire growth rate, 3. the compartment floor area and 4. the compartment height. A parameter study revealed how the significant factors affect the maximum cable temperature in fictitious compartment fires. The results of the parameter study are transferred on true Nuclear Power Plant compartments. However, it is not possible to determine precisely the occurrence of an electrical cable failure because of uncertainties in the maximum cable temperature and the failure temperature. The probabilistic set of filter criteria considers these uncertainties and determines the probability of cable failure for true compartments to be screened in Fire PSA. Finally, a compartment can be screened out in Fire PSA if the failure probability exceeds a predefined accepted threshold value for the failure probability. The theoretical application of the methodology is shown at the end of the paper.
Experimentelle Untersuchungen zum Einfluss von Brandbeschleuniger auf den Verlauf von Raumbränden
(2013)
Computer simulation tools were used to evaluate pedestrian movement. This study compares the reliability of three simulation tools and the calculation method by Predtetschenski und Milinski with a controlled evacuation exercise of a lecturer room. The comparison shows that each simulation tool used underestimate the total evacuation time and that an indicator for a low level of fitness does not necessarily lead to a long evacuation time. Results revealed that calibration of simulation tools is required to model heterogeneous population properly. Therefore, further experiments with a realistic, heterogeneous composition of participants have to be made.
Um den Anforderungen der Bauordnung an den Brandschutz für Gebäude gerecht zu werden, sind bauliche Anlagen so zu errichten und zu betreiben, dass der Entstehung eines Brandes und der Ausbreitung von Feuer und Rauch vorgebeugt, die Rettung von Menschen und Tieren sowie wirksame Löscharbeiten ermöglicht werden.
Hierbei besteht, einer steigenden Komplexität sowie einem differenzierten Nutzungskonzept öffentlicher Gebäude geschuldet, häufig die Notwendigkeit von normativen Vorgaben abzuweichen und dennoch ein gleichwertiges Sicherheitsniveau nachzuweisen.
Es werden Personensimulationsmodelle eingesetzt, die einerseits das Vorhandensein eines Schutzzielniveaus durch die Abbildungen von Personenbewegungen nachweisen können und andererseits durch Parametervariation eine szenarienabhängige Betrachtung ermöglichen.
Der vorliegende Beitrag vergleicht die Ergebnisse einer kleinskaligen Evakuierungsübung mit drei mikroskopischen Personensimulationsmodellen und geht der Frage nach der Aussagekraft dieser Bewertungsmethode nach. Es zeigt sich, dass die alleinige Betrachtung absoluter Entleerungszeiten keine zuverlässige Beurteilungsgrundlage für das komplexe Schutzziel Personensicherheit darstellt.
Vor dem Hintergrund der Zurückziehung der DIN 18230 Teil 2 zur Bestimmung des m-Faktors von Materialien für die Brandlastbewertung im Industriebau müssen neue Wege gefunden werden, wie das Abbrandverhalten alternativ quantifiziert werden kann. Der Beitrag fasst die Entstehung und die Entwicklung der Bestimmungsweise von Abbrandfaktoren zusammen und gibt Ausblick auf eine neue Möglichkeit zur Bewertung von Brandlasten, die Verbrennungseffizienz.
Die Einführung von Wasserstoff als sicherer Energieträger braucht eine robuste Wissensbasis, darauf aufgebaute Werkzeuge zur Auslegung und Sicherheitsbewertung von Wasserstofftechnologien und ein international harmonisiertes Regelwerk. Viele der innovativen Technologien implizieren Wasserstoff bei hohen Drücken und/oder kryogenen Temperaturen, mit denen in verteilten Anwendungen erstmalig private Nutzer in Kontakt kommen. Um überkonservative, teure Sicherheitslösungen zu vermeiden, gleichzeitig aber die Einsetzbarkeit und Sicherheit von Wasserstoffanwendungen zu demonstrieren und die Akzeptanz für die Technologie aufrecht zu halten, muss auch die Sicherheitsforschung mit den Trends der technologischen Entwicklung Schritt halten, oder sie besser noch antizipieren. So beschreibt dieser Überblicksartikel nicht nur den gegenwärtigen Stand der Kenntnisse und Technik bezüglich Wasserstoffsicherheit, sondern auch ihre Weiterentwicklung.