A research project is described involving a comparison of different non-destructive test methods for concrete bridges. A cooperative test series was started with the aim to compare and evaluate the performance and benefits of the latest technical developments in this field. For this purpose test specimens with localized defects were produced. Different modifications of radar, ultrasonic-echo and impact-echo methods were investigated. Including two- and three- dimensional reconstruction models. The experiments were accompanied by numerical simulation of the propagation of sound waves and microwaves. The results showed that the radar and the ultrasonic methods were efficient tools to locate the tendon ducts accurately if the reinforcing bars were not to narrowly spaced. The ultrasonic imaging methods were capable of identifying injection and compaction faults in a blind test. The good performance of the impact-echo method with regard to locating tendon ducts which was claimed in several publications could not be validated in the present investigations. The simulation models provided valuable information on how to improve the experimental test program and its evaluation.
ZfPBau-Kompendium 2004
(2007)
Dieses Kompendium ist ein kurzgefasster Abriss, ein Leitfaden und auch ein Handbuch der für den Einsatz im Bauwesen geeigneten zerstörungsfreien Prüfverfahren. In strenger, stets gleicher Gliederung wird jede der mehr als 100 Untersuchungsmethoden in einem eigenen Geräteblatt beschrieben. Hinzu kommen Querverweise zu alternativen Prüfmethoden sowie zahlreiche Hinweise auf einschlägige Fachliteratur und zu bekannt gewordenen Geräteherstellern, Lieferanten und Dienstleistern.
Today's civil engineering NDT needs are for quantitative, fast to apply and easy to interpret methods. They are required on site both for evaluation of existing structures/infrastructure and for quality control in new construction. With this purpose, BAM has carried out in-situ feasibility studies, using radar, impact-echo and ultrasonic-echo methods. Two examples are given of their combined application on different railway slab–track constructions, using high frequency radar, scanning impact-echo and ultrasonic array methods. The aim was to evaluate limitations and advantages, comparability and complementarity of these methods. The on-site measurements demonstrated the possibility to investigate, with good accuracy via NDT, the bonding conditions between sleepers and slab, to locate voids and measure layer thickness. The acoustic and electromagnetic methods used, were found to be complementary.
Entwicklung einer Gruppenstrahler-Sendeeinheit für Ultraschalluntersuchungen von Betonbauteilen
(2002)
Zusammenfassung
Die Ultraschall Phased-Array-Technik oder auch Gruppenstrahlertechnik wird erfolgreich in der zerstörungsfreien Werkstoffprüfung an Metallen und Kunststoffen eingesetzt. Mit dieser Technik kann durch zeitlich gesteuerte Anregung der einzelnen Wandlerelemente des Arrays das Schallbündel im Probekörper verschoben, geschwenkt und/oder fokussiert werden. Der für Beton anwendbare Frequenzbereich liegt in der Regel von 50 kHz bis 200 kHz. Die Erzeugung der notwendigen Verzögerungen der Sendespannungen für die Schallbündelsteuerung kann in diesem Frequenzbereich durch kommerziell erhältliche Komponenten der Rechnertechnik erreicht werden. Die Hardware-Entwicklung beschränkt sich somit nur auf die Leistungssendestufen und das Interface zwischen dem Steuerrechner und dem Leistungsteil.
Die Phased-Array-Sendeapparatur besteht aus einem Steuerrechner mit eingebauten Timerbaugruppen und einem externen Leistungsteil mit 10 eingebauten Sendern für die Ultraschallprüfköpfe. Als Kompromiss zwischen Schaltungsaufwand und bestmöglicher Anregung werden z. Zt. Rechtecksendestufen mit einstellbarer Impulsbreite verwendet. Durch die variable Impulsbreite kann, je nach verwendeten Prüfköpfen, die Anregung optimiert werden.
Orientierende Messungen wurden an einem 50 cm dicken Betonprobekörper mit einem Größtkorn von 8 mm durchgeführt. Die Möglichkeiten des Fokussierens und des Schwenkens des Schallbündels sind in Durchschallung überprüft worden. Es erfolgte danach ein Vergleich der Ergebnisse mit einer Modellrechnung auf Grundlage der Punktquellensynthese.
The structural safety, durability and performance of the infrastructure is of primary interest in every country. An efficient system for early and regular structural assessment as well as for quality assurance during and after the construction of new structures and of reconstruction processes is urgently required. At BAM, NDT methods to be applied in civil engineering are developed and their application improved. From the experience of on-site assessments, quality assurance systems and methodologies for regular inspections are elaborated. This work is mainly performed in the frame of externally funded research projects.
Für die Strukturaufklärung von Betonbauteilen existieren mehrere bildgebende Ultraschallecho-Verfahren, u. a. mit Nutzung des Prinzips der synthetischen Apertur. Die Ergebnisse werden mit unterschiedlichen Verfahren, mit oder ohne Anwendung von Rekonstruktionsrechnungen, ausgewertet und in der Regel als B- bzw. C-Bilder dargestellt.
Ziel ist es, die unterschiedlichen Verfahren anhand von Messreihen an Testkörpern mit bekannten Prüfobjekten in Hinblick auf Ihre Leistungsfähigkeit quantitativ zu fassen und zu vergleichen, um den Einsatz der Prüfverfahren bei Untersuchungen unbekannter Objekte zu optimieren. Dazu wurden drei Kenngrößen definiert. Als erster Schritt erfolgte die Anwendung der Definitionen auf vorliegende Messergebnisse zu einer in einem 50 cm dicken Betontestkörper parallel zur Messfläche eingebrachten Bohrung.
Non-destructive testing (NDT) of concrete structures is performed using pulse-echo methods. According to the type of the applied waves it can be classified as acoustic (Impact-Echo, Ultrasonics) and electromagnetic methods (Radar). The results are visualised through different imaging processes. This work is performed in the frame of a research project promoted by Deutsche Forschungsgemeinschaft (FOR384).The objective of data fusion is to use the complementary information of the different methods. Radar can detect metallic reflectors in concrete (metallic ducts and concrete reinforcement) very well. This method is not able to locate defects behind these reflectors (injecting defects, defects behind close concrete reinforcement), because the electromagnetic waves are completely reflected at metals. The acoustic methods are able to compensate this deficit i.e. acoustic waves can penetrate through metal. But acoustic waves in the ultrasonic range are completely reflected by air layers. Air layers have smaller influence on radar propagation, so that both methods complement each other.In order to be able to combine the NDT-data from several methods records at the same volume, the different data setsmodes of signals must be adapted. The ultrasonic and radar data have to be reconstructed with programs based on the Synthetic Aperture Focusing Technique (SAFT) before data fusion. Subsequently, a conversion of the data into a uniform format has to be carried out. This is a prerequisite in order to keep the data exchange between the project partners as simple as possible. After the data sets are imported and transferred into a common reference system, they can be processed with operations according to the purpose of the investigation. Results, which have been achieved in concrete test specimen with radar and ultrasonics, will be presented and will show the feasibility of the data fusion method.
Die Risstiefenbestimmung in Festen Fahrbahnen ist hinsichtlich der Dauerhaftigkeit der Konstruktion von wesentlichem Interesse. Im Rahmen eines gemeinsamen Forschungsvorhabens mit der DB AG wurden aus der Literatur bekannte Ansätze bewertet und darauf aufbauend ein Verfahren zur bildgebenden Rissdarstellung entwickelt. Rissüberbrückende Bewehrung sowie Kontaktstellen zwischen den Rissflanken wirken als Schallbrücken und erschweren die Risscharakterisierung, wie bei einem Einsatz an einer Betriebserprobungsstrecke festgestellt wurde. Ein aus der Literatur bekanntes Verfahren der einfachen Laufzeitmessung erwies sich für die Tiefenbestimmung von realen verunreinigten Rissen als ungeeignet.
Im Rahmen eines FE-Projektes “Inspektion Fester Fahrbahnen“ der BAM und der Deutschen Bahn AG geht es um die Anwendung und weitere Entwicklung zerstörungsfreier Messverfahren zur Beurteilung des Zustandes Fester Fahrbahnen.
Nach ersten Versuchsreihen direkt im Gleis wurden für verschiedene Bauarten die charakteristischen Herstellungsbedingungen simuliert und systematisch untersucht. Die kombinierte Anwendung der drei Messverfahren Ultraschall-Array-, Impakt-Echo- und Impuls-Radar-Verfahren wird hier an dem Beispiel “Betonschwelle in Betoneinbettung” dargestellt.
Since several years ultrasonic imaging techniques are used for testing concrete elements. Combined with a reconstruction calculation they lead to an acoustic imaging of scatterers and reflectors from the inside of the concrete element. For several testing problems it is an advantage to use a two dimensional synthetic aperture and to combine it with a three-dimensional reconstruction calculation (3D-SAFT, Synthetic Aperture Focussing Technique).
This enables the analysis of the tested volume by means of B-scans in two directions and C-scans (projections parallel to the surface), respectively. Using the 2D-scanning technique, especially the disturbing influence of the reinforcing rebars can be minimised.
In this contribution the state of the art of this method is demonstrated and analysed. Examples of the application are presented, concerning
Localisation of honeycombing and compaction faults
Characterisation of cracks (especially measuring the crack depth)
Investigation of tendon ducts
The results presented are obtained in the frame of a research initiative Non-destructive Evaluation of Concrete Structures Using Acoustic and Electromagnetic Echo-Methods supported by the German Science Council (FOR 384 of DFG, Deutsche Forschungsgemeinschaft). The methods are assessed and improved in cooperation with the partners participating in the project.
Verfahrensentwicklung zur Qualitätssicherung Fester Fahrbahnen mit zerstörungsfreien Prüfverfahren
(2002)
Zusammenfassung
Die Anwendung des Ultraschallecho-Verfahrens zur Hohlstellenortung in Holzbalken wird beschrieben.
An Hand der Versuchsergebnisse wird der Einfluss der Anisotropie des Holzes auf die Messkopfanordnung und Schallgeschwindigkeit dargestellt. Mit der optimierten Messanordnung ist die erfolgreiche Detektierung von Nachbildungen von Minderdicken und Kernfäule möglich. Besonders klar sind Schäden in Faserrichtung (Kernfäulenachbildung) nachzuweisen. Die sehr guten Ergebnisse zeigen die Anwendbarkeit des Ultraschallecho-Verfahrens an Holz.
Improved Detection of Tendon Ducts and Defects in Concrete Structures Using Ultrasonic Imaging
(2002)
At the beginning of the 90s the general opinion was, that ultrasonic inspection methods using pulse-echo technique were not suitable for the inspection of concrete because of the inhomogeneity and the strong scattering behavior of the embedded aggregates. In the meantime the progress in the development of new equipment and inspection strategies in connection with ultrasonic imaging techniques turns the pulse-echo technique into a powerful tool to solve problems related to concrete materials. These imaging techniques - developed for the inspection of homogenous materials like steel of aluminum - could be adopted to the very low frequencies needed for concrete inspections.
Ultrasonic investigation is an established non-destructive testing method for detection of defects and material characterisation. In the last years scanning ultrasonic echo methods were developed especially for the application in civil engineering.
The different scanning ultrasonic echo methods are modified with respect to the type of the transducer applied, the number and the arrangement of transducers and the frequency used. Also different algorithms are used to analyse the measured data, for instance SAFT (Synthetic Aperture Focusing Technique) reconstruction. The results are typically presented as B- and C-scans, obtained from raw data or the SAFT reconstructed data.
Since 2001 several German research institutes co-operate within the scope of the research initiative Non-destructive Evaluation of Concrete Structures Using Acoustic and Electromagnetic Echo-Methods (FOR 384) supported by the Deutsche Forschungsgemeinschaft (DFG). One of the tasks is to investigate these ultrasonic echo methods for special applications like the detection of cavities in concrete structures or faults in tendon ducts.
Concrete test specimens with intentional faults have been manufactured and investigated. Parameters were defined to assess the results more objectively. Currently three parameters -signal/noise-ratio, lateral edge resolution and uniformity- are considered. For the first time results of different working groups on the same imaged objects are compared quantitatively. It should help to get more knowledge about the ultrasonic inspection of typical faults in civil engineering structures.
Ultrasonic reconstruction by the synthetic aperture focusing technique (SAFT) has a great potential to image concrete elements and detect embedded objects. Its algorithm focuses ultrasonic signals received at many aperture points by coherent superposition, yielding a high-resolution image of the region of interest. Using this approach, several problems caused by the strongly inhomogeneous structure of concrete are diminished, where scattering of transmitted pulses leads to disturbing phenomena such as attenuation and structural noise. This contribution is intended to review the work of the writers on the application of SAFT reconstruction to concrete testing. First, consequences of scattering of ultrasonic waves in concrete are qualitatively explained. Then the use of SAFT is discussed in comparison to traditional A-scan and B-scan techniques. Different reconstruction algorithms and implementations are presented for one-, two-, and three-dimensional SAFT. Pulse-echo measurement systems are described, which are able to acquire large sets of data on linear and planar apertures employing single transducer, transducer array, and scanning laser Doppler vibrometer arrangements. To illustrate the application of the SAFT techniques, examples from laboratory and field experiments are described comprising imaging of back walls, tendon ducts containing faults, layers, and reinforcement in concrete elements.
Laser vibrometric contactless sound field measurements at a concrete test block are presented. Both excitation by an ultrasonic probe and by an impactor were used. The wave modes can be identified by their geometric wave forms and propagation velocities. Additionally, numerical simulation of the experimental situation is used to support this interpretation. Possible applications of the presented technique are discussed. ©2005 American Institute of Physics
During the re-use process of existing concrete memebers like foundations information about geometry and location of piles or strip foundation is necessary. Ultrasonic echo with a need of only one-sided access may provide this information and help the engineer to assess foundations. Cost effectiveness by the re-use of foundations gains an increasing economic role due to decreasing average economic lifetime of buildings on urban sites. Results of systematic ultrasonic echo investigations at a slab from 75 cm to 125 cm thickness with ten different reinforcement ratios are presented. The influence of the varying reinforcement ratio and thickness on the reliability of the results is shown. Available data-processing algorithms based on reconstruction calculation and imaging of results to reveal the geometry of a slab and the location of piles or strip foundations are introduced. Practical guidance for the application of ultrasonic echo and its limits are presented to ensure reliable results.
Non-destructive Testing of a Post tensioned Concrete Bridge Applying an Automated Measuring System
(2004)
In der BAM wurde als Gemeinschaftsvorhaben der Fachgruppe „Zerstörungsfreie Schadensdiagnose und Umweltmessverfahren“ ein rechnergesteuerter Messabtaster für Bauwerksteile (Baustellenscanner) entwickelt. Es handelt sich um ein auf Schienen verfahrbares modulares System mit einem multifunktionalen Messkopf für mehrere zerstörungsfreie Prüfverfahren. Mit dem Baustellenscanner können Objekte wie Brücken oder Fundamentplatten schneller und genauer als bisher bei gleichzeitig reduziertem Personalaufwand untersucht werden.
Non-destructive Testing of a Post tensioned Concrete Bridge Applying an Automated Measuring System
(2004)
Kurzfassung
Die Anwendung niederfrequenter Ultraschall-Echotechnik mit Longitudinal- und Transversalwellen für die Materialuntersuchung von Holzbauteilen wird beschrieben. Weiterhin wird der Einfluss der Holzfasern auf die Schallgeschwindigkeiten und Oberflächenwellen an Hand von Messergebnissen aufgezeigt. Die Leistungsfähigkeit des Ultraschall-Echoverfahrens an ungeschädigten Holzkörpern und Körpern mit eingebrachten Bohrungen in Faserrichtung (Kernfäulnissimulation) wird dargestellt. Es ist zudem möglich, bei koppelmittelfreier Ankopplung mit Transversalwellen indirekt Fäulnis von der ungeschädigten Bauteilseite aus zu orten. Als Referenzverfahren werden die Bohrwiderstandsmethode oder die Röntgendurchstrahlung eingesetzt.
In diesem Beitrag wird die Anwendung von Radiographiesystemen zum Auffinden von Holzschäden beschrieben. Die Anlage besteht aus einer mobilen Röntgenblitzröhre und einem digitalen Radiographiesystem mit Speicherfolie oder einem Flachdetektor. An Hand der durchgeführten Versuche an Laub- und Nadelbäumen sowie an Eichenbalken der Marienkirche der Lutherstadt- Wittenberg wird die Detektion innerer Schäden gezeigt.
Non-destructive testing (NDT) of concrete structures is performed using pulse-echo methods. According to the type of the applied waves it can be classified as acoustic (Impact-Echo, Ultrasonics) and electromagnetic methods (Radar). The results are visualised through different imaging processes. This work is performed in the frame of a research project promoted by Deutsche Forschungsgemeinschaft (FOR384). The objective of data fusion is to use the complementary information of the different methods. Radar can detect metallic reflectors in concrete (metallic ducts and concrete reinforcement) very well. This method is not able to locate defects behind these reflectors (injecting defects, defects behind close concrete reinforcement), because the electromagnetic waves are completely reflected at metals. The acoustic methods are able to compensate this deficit i.e. Acoustic waves can penetrate through metal. But acoustic waves in the ultrasonic range are completely reflected by air layers. Air layers have smaller influence on radar propagation, so that both methods complement each other. In order to be able to combine the NDT-data from several methods records at the same volume, the different data setsmodes of signals must be adapted. The ultrasonic and radar data have to be reconstructed with programs based on the Synthetic Aperture Focusing Technique (SAFT) before data fusion. Subsequently, a conversion of the data into a uniform format has to be carried out. This is a prerequisite in order to keep the data exchange between the project partners as simple as possible. After the data sets are imported and transferred into a common reference system, they can be processed with operations according to the purpose of the investigation. Results, which have been achieved in concrete test specimen with radar and ultrasonics, will be presented and will show the feasibility of the data fusion method.
Validation of non-destructive testing methods is necessary to create a common basis where different systems can be compared and their applications and limitations be identified. This can be achieved through comparing the measurements taken by several systems used for a common diagnostic purpose under practical but controlled testing conditions. Well-designed small and large laboratory or field specimens promise such conditions.
The special concrete specimen (LCS) at BAM was constructed for validation purposes, in particular, to be used for evaluating the performance of echo methods. The thickness of the specimen is varying and it contains carefully designed built-in faults, such as voids, honeycombs and tendon ducts with various degrees of grouting defects. Since the geometry and condition of the defects are known, it can be used to compare the performance of radar, ultrasonic, impact-echo. The research was conducted within the Research group FOR384, sponsored by the German Research Society DFG.
Characterization of reflector types by phase-sensitive ultrasonic data processing and imaging
(2008)
Ultrasonic and radar imaging techniques are limited in resolution by the wavelength in the material, yet information beyond those limits is hidden in complex frequency dependent reflection coefficients. The analysis of the phase of complex reflection coefficients together with the properties of imaging algorithms can help to characterize and to classify indications of defects in concrete buildings. This paper describes a method to extract phase information from measurements and SAFT reconstructed images. The influencing factors like material properties, transducer characteristics, and imaging algorithms based on Born or Physical Optics approximations are elaborated. Simulated and experimental results are briefly discussed.
This paper presents the progress of successful location of grouting faults in tendon ducts with ultrasonic imaging. The examples were obtained in the research group FOR 384 funded by DFG (German Research Foundation). The co-operation of experimental research and modeling allowed imaging and identification of grouted and ungrouted areas of tendon ducts (including strands) in a large test specimen (40 m²). In addition to the criteria for indicating grouting faults in post-tensioned ducts known until now the phase evaluation of reflected ultrasonic pulses is described. Experiments and modeling of wave propagation are presented for reflections at metal plates in concrete (thickness range 0.5 mm to 40 mm) and for tendon ducts including strands.
The main part of the progress was achieved by automated measurements using dry contact transducers, 3D-SAFT reconstruction including phase evaluation and modeling considering wave propagation for typical elastic parameters and exact experimental site conditions. The results for shear waves as well as for pressure waves are compared in the frequency range from 50 kHz to 120 kHz.
Influence of concret properties on the calibration of radar, ultrasonics and active thermography
(2008)
Features for ultrasonic imaging of concrete elements: Phase evaluation and air coupled ultrasound
(2008)
Ultrasonic Reflection Properties at Interfaces Between Concrete Steel and Air: Imaging and Modelling
(2006)
Für die zerstörungsfreie Prüfung großer Betonbauwerke unter dem Aspekt der Analyse von Spannkanälen hat sich die Ultraschalltechnik in den letzten Jahren als geeignete Methode herausgestellt, da sowohl die Messtechnik insbesondere die Ultraschallwandler als auch die numerischen Auswerteverfahren in einem Stadium sind, das es erlaubt, größere Messflächen und damit größere Volumina zu beschallen und abzubilden. Mit Hilfe der Modellierung der Ausbreitung elastischer Wellen in komplexen Medien können praxisrelevante Problemstellungen untersucht werden, auch unter dem Aspekt, Testkörper zu planen oder gar zu ersetzen. Durch die Auswertung der Phase der Rekonstruktion eines Streuvorgangs können Fehlstellen klassifiziert und damit Aussagen über die Bauwerkssicherheit signifikant objektiviert werden. Die Methoden werden, im Hinblick auf eine ganzheitliche Sichtweise von skalaren und polarimetrischen Abbildungsverfahren mit Unterstützung der Modellierung und der anschließenden Klassifizierung durch Phasenanalyse, an ausgewählten Beispielen erläutert.
For nondestructive testing of concrete buildings under the aspect of tendon duct analysis, ultrasonic testing has proven to be a suitable method, as both the measuring technique in particular the acoustic sensors and the numerical methods allow the insonification and imaging of larger surfaces and volumes. With the aid of numerical modelling of elastic wave propagation in complex media real life problems can be examined with the goal to design or even to replace test specimen. By determination of the phase of an imaged scattering event, defects can be classified, and the prediction of the integrity of buildings can be significantly objectified. The methods are explained for selected examples in an integral way with respect to scalar and polarimetric imaging algorithms supported by modelling and subsequent classification through phase analysis.
Aktuell wird die Ultraschallechotechnik für Holzbauteile genutzt, indem aus der Abschattung eines ansonsten stabilen Rückwandechos auf Auffälligkeiten im Holzbauteil geschlossen wird. Dabei werden Transversalwellen (Mittenfrequenz 50 kHz) mit der Polarisationsrichtung in Faserrichtung (L) angewendet. In einem 2012 abgeschlossenen Forschungsvorhaben wurde nun die direkte Abbildung von Streuern durch anisotrope SAFT-Rekonstruktion entwickelt.
Dazu werden flächig aufgenommene Ultraschallmessdaten mit automatisiert scannenden Druck- und Scherwellenköpfen erzeugt und auf Basis anisotroper Geschwindigkeitsverteilungen rekonstruiert. Benutzt werden die auch häufig für Beton eingesetzten trocken ankoppelnden Punktkontakt-Prüfköpfe. Da damit auch intensive Wellen an der Oberfläche erzeugt werden, entstehen im Material zusätzliche Kopfwellen, die ebenfalls bei der Rekonstruktion berücksichtigt werden.
Da die Wellengeschwindigkeiten in Holz individuell stark schwanken, wird eine interaktive Auswertetechnik zur Ermittlung der Materialkonstanten benutzt. Für die Messungen werden Druckwellen sowie Scherwellen in zwei Polarisationsrichtungen verwendet. Die Messungen erfolgen sowohl mit automatischen Scannersystemen als
auch mit einem linearen Prüfkopf-Array (kommerziell erhältlicher multistatischer Messkopf). Gezeigt werden Ergebnisse an Bauteilen mit künstlichen und realen Fehlstellen. Das Forschungsprojekt wurde gefördert vom Bundesamt für Bau- und Raumordnung (BBR, Zukunft Bau).
There is a great demand for non-destructive testing methods for quality assurance and to assess the safety and durability of wooden structures. Ultrasonic echo technique with shear waves in the frequency range of 50 kHz is one of those promising methods and is already frequently applied for usual and glued laminated timber. The article describes the development and first results for an imaging method for this purpose. The highly anisotropic properties of the ultrasonic velocity have to be considered. A 3D-SAFT (Synthetic Aperture Focusing Technique) imaging scheme is developed initially for synthetic data resulting from modelling the elastic wave propagation. The main part of the paper describes the experimental validation of this evaluation technique by experimental studies applying automated ultrasonic scanning techniques. 3D ultrasonic imaging results are described for test specimens made from pine and spruce wood. Another object of investigation was a pedestrian bridge made from siberian larch.
Ultrasonic imaging of tendon ducts enables the precise localisation of grouting faults in many cases. Additionally to well known criteria for detecting grouting faults in tendon ducts recently new possibilities were developed. Two main effects influence the complex behaviour of wave propagation and reflection: a) different arrangement and number of strands or internal rebars; b) superposition of reflecting signals and different wave modes propagating into the interface region around the tendon duct. In order to understand the experimental results, EFIT modelling is performed (EFIT: Elastodynamic Finite Integration Technique).
In Zeiten knapper Kassen wird überall nach Wegen gesucht Kosten einzusparen. Im Bauwesen geht es dabei um Kosteneinsparungen ohne Reduktion der Sicherheit und Dauerhaftigkeit des Bauwerks. Beim Bauen im Bestand können mit einer zerstörungsfreien Prüfung von Bauwerken die Weiternutzung oder die erforderlichen Umbauten optimiert werden und so Kosten eingespart werden.