This work focuses on the question if the bubble test prescribed in the Dangerous Goods Regulations has sufficient sensitivity to detect leakage rates, which could result in the formation of explosive atmospheres during transport. The sensitivity of the bubble test is not directly comparable with other leak testing methods because of its different flow conditions. Therefore, a normalized minimum detectable leakage rate under Helium test conditions is calculated for the bubble test. This sensitivity of the bubble test under reference conditions is compared with limit leakage rates for a worst‐case transport scenario. The sensitivity of the bubble test is not sufficient to prove the limit leakage rates for 6‐L packagings. The formation of explosive vapour‐air‐mixtures cannot be excluded. Therefore, more sensitive leak testing methods should be considered for smaller packaging design types.
The objective was to find out whether an explosive atmosphere can be created in a freight container by gaseous leakage flow of vapour-air-mixture through leaks in the closures of dangerous goods packagings filled with hazardous liquids. Because of high temperatures during intercontinental carriage, there is a gauge pressure in the free vapour phase inside the packagings which can cause a gaseous leakage flow. Two different methods were applied:
Helium limit leakage rates for 23 quantitatively important hazardous liquids concerning their lower explosion limit (LEL) were calculated for a worst case transport scenario (Method 1).
Helium leakage rates of five closure types of dangerous goods packagings with volumes of approximately 6 l were measured using the pressure technique by accumulation (Method 2).
All types of closures of steel packagings were uncritical. The maximum measured leakage was 33% of the limit leakage rate. The leakage rates of screw closures of plastic jerricans can exceed the LEL if there are production-related patterns such as non-concentricity of the closures and flashes on the neck. Especially for plastic packagings it is important to minimize gaseous leakage flow, because an explosive atmosphere can also be reached by permeation of the individual filling substance or by a combination of both effects. For the assessment of potentially explosive mixtures in freight containers, both mass transfer mechanisms have to be taken into account.
The International Dangerous Goods Regulations prescribe the immersion under water method (“bubble test”) as standard method for the leakproofness test of dangerous goods packagings. But this test procedure acts as a test method for leak localisation, not for quantitative leakage rates measurement. Additionally, the sensitivity in detecting leaks of small diameters is restricted, depending on the test liquid and the test pressure. The bubble test is not suitable for a comparison with quantitative limit leakage rates based on realistic transport conditions. This is especially important when estimating the risk of the formation of an explosive atmosphere during the intercontinental carriage of dangerous goods packagings in freight containers. To compare measured leakage rates with limit leakage rates, a quantitative leak testing procedure is required. Therefore a new approach for dangerous goods packagings is implemented: The pressure technique by accumulation using Helium as a tracer gas. This work presents the test equipment necessary for the quantitative measurement of Helium leakage rates through closures of different kinds of dangerous goods packagings. The essential steps to achieve good repeatable results are: A controlled Helium filling process to reach a defined test pressure in the test sample, a sufficient homogenisation of the Helium-air-mixture inside the test sample and the ensuring of a constant pressure level of the test sample during the test. The Helium loss rate of the accumulation chamber has to be measured separately to receive a correction factor for the measured leakage rates. Different constructional measures are introduced to prevent a disturbing influence of the Helium leakage rate of the filling valves on the measurement results. Methods to estimate the disturbing effect of Helium permeation through permeable parts of the test sample are also presented. As a supporting method for the experimental investigations the Helium sniffer test can be applied. This practical application-oriented advice can enable other users to establish a pressure technique by accumulation for their own technical field.