Filtern
Erscheinungsjahr
- 2013 (6) (entfernen)
Dokumenttyp
Sprache
- Englisch (6) (entfernen)
Schlagworte
- Accelerant (1)
- Analytik (1)
- Arson analysis (1)
- Chemical analysis (1)
- Cone calorimeter (1)
- Controlled-atmosphere cone calorimeter (1)
- Fire behaviour (1)
- Fire debris (1)
- Fire resistance (1)
- Flame retardancy (1)
Mixtures of hexamethyldisiloxane (HMDSO) and oxygen have been used for deposition of SiO2-like layers by plasma polymerization under low-pressure conditions onto polyethylene and polystyrene used as basecoat. Water glass was cast onto these 0.5 µm plasma thick siloxane-like layers with a thickness of 5 to 40 µm. The adhesion of these bilayer systems and their flame resistance were tested.
The effect of different plasma parameters such as monomer/gas ratio, pressure and power input into the discharge on the deposition rate and the composition of the formed layers was studied. Characterization and chemical composition of the formed films were performed using infrared, X-ray photoelectron and solid state nuclear magnetic resonance spectroscopy.
Peel strengths of composites were measured and the locus of peel front propagation was detected. Thermal properties of composites were analyzed by thermo-gravimetric analysis. Finally, the fire-retardant properties of thick coated polymers were determined by exposure to flames and the behavior of coatings on the polymers during flaming was observed visually.
Mixtures of hexamethyldisiloxane (HMDSO) and oxygen have been used for deposition of SiO2-like layers by plasma polymerization under low-pressure conditions onto polyethylene and polystyrene used as basecoat. Water glass was cast onto these 0.5 pm plasma thick siloxane-like layers with a thickness of 5 to 40 mu m. The adhesion of these bilayer systems and their flame resistance were tested. The effect of different plasma parameters such as monomer/gas ratio, pressure and power input into the discharge on the deposition rate and the composition of the formed layers was studied. Characterization and chemical composition of the formed films were performed using infrared, X-ray photoelectron and solid state nuclear magnetic resonance spectroscopy. Peel strengths of composites were measured and the locus of peel front propagation was detected. Thermal properties of composites were analyzed by thermo-gravimetric analysis. Finally, the fire-retardant properties of thick coated polymers were determined by exposure to flames and the behavior of coatings on the polymers during flaming was observed visually.
A controlled-atmosphere cone calorimeter that is built by modifying the Standard apparatus with the addition of a controlled-atmosphere chamber offers a time- and cost-saving approach for reaction-to-fire testing in vitiation- and ventilation-controlled atmospheres. Due to the design of the added enclosure no mechanical changes on cone calorimeter’s Standard ductwork are required. This offers some advantages but also important limitations. The design has an open connection between the outlet of the added enclosure and the cone calorimeter’s exhaust hood. Therefore, sufficient ambient air from the laboratory surroundings is drawn into the System to introduce effects which have the potential to affect test results significantly.
A procedure which is is suitable to consider physical effects of the ambient air on the calculation of the heat release rate is presented as well as initial results of an application towards toxic potency assessment. Signs for Chemical effects of the ambient air such as post reactions are shown but subject of an ongoing work.
The influence of fire accelerants on the fire behavior during living room fires was experimentally investigated by performing 5 different room fire scenarios. During the tests flre-technological quantities were determined as well as chemical-analytical studies were carried out. The focus was on the detection of smoke gases and the proof of used fire accelerants. The evaluation of traceable fire accelerants and the reconstruction of the fire development are based on a precise Chemical analysis of the combustion products.
In this work an innovative methodology was developed to combine available analyticai techniques to draw conclusions from solid, liquid and gaseous fire residues about the fire process. Each ofthe fire rooms was equipped with the same living room inventory. The location and amount of fire accelerant (a mixture of diesel/gasoline) differed in 4 of 5 tests. Orte room fire experiment was carried out without fire accelerant.
The following fire technological characteristics were determined during the room fire experiments: mass loss (of the complete room), temperatures (at several locations in the room), heat release and smoke gas emission (measured at three different locations: in the chimney, in the fire room and at the door opening).
While the smoke gases were analysed by using Fourier Transform Infrared spectroscopy, the fire residues and swipe samples (particles) were examined by Headspace-Solid Phase Microextraction-
Gaschromatography-Mass spectrometry. These procedures make it possible to detect low concentrations of volatile components of the fire accelerants. The Chemical analyticai results of the fire accelerant detection are presented.
The chemical analysis of fire debris represents a crucial part in fire investigations to determine the cause of a fire. A headspace solid-phase microextraction (HS-SPME) procedure for the detection of ignitable liquids in fire debris using a fiber coated with a mixture of three different sorbent materials (Divinylbenzene/Carboxen/Polydimethylsiloxane, DVB/CAR/PDMS) is described. Gasoline and diesel fuel were spiked upon a preburnt matrix (wood charcoal), extracted and concentrated with HS-SPME and then analyzed with gas chromatography/mass spectrometry (GC/MS). The experimental conditions—extraction temperature, incubation and exposure time—were optimized. To assess the applicability of the method, fire debris samples were prepared in the smoke density chamber (SDC) and a controlled-atmosphere cone calorimeter. The developed methods were successfully applied to burnt particleboard and carpet samples. The results demonstrate that the procedure that has been developed here is suitable for detecting these ignitable liquids in highly burnt debris.
At the moment more than 1 Million photovoltaic (PV) power generators are connected to the national grid in Germany1. This leads to an increasing number of estimated 300 fire accidents caused by this technology every year. Often the fire brigades deny extinguishing a burning PV generator. The fear of electric shock and poisonous heavy metals in PV solar panels refrain the firemen from doing their task. The cause of a fire of PV Systems can be the ignition of the building where the generator is mounted on, arson or technical errors in the PV modules, like strings or the inverter.