Filtern
Erscheinungsjahr
Dokumenttyp
- Zeitschriftenartikel (36)
- Beitrag zu einem Tagungsband (27)
- Posterpräsentation (13)
- Beitrag zu einem Sammelband (11)
- Sonstiges (1)
Sprache
- Englisch (88) (entfernen)
Schlagworte
- Polycondensation (6)
- MALDI (5)
- MALDI-TOF-MS (4)
- Oligomers (4)
- Macrocycles (3)
- Macrocyclics (2)
- Model compounds for melanoidins (2)
- Polyesters (2)
- Thermodynamics (2)
- 1,1-Diphenylethylene (1)
- 29Si NMR (1)
- Alternating sequence (1)
- Antioxidative activity (1)
- Antioxidative activity of oligomeric model compounds (1)
- Beta-dicarbonyl pathway of the Maillard reaction (1)
- Biodegradable polyesters (1)
- Captive bubble (1)
- Chain transfer (1)
- Change of crystal structure (1)
- Chromatographie (1)
- Chromatography (1)
- Coatings (1)
- Copolymer structure (1)
- Coupling methods (1)
- Crystallization (1)
- Cyclization (1)
- Dental (1)
- Emulsion polymerization (1)
- Gel permeation (1)
- Glass transition temperature (1)
- Hard segments (1)
- Hydrophobicity (1)
- Ionization mass spectrometry (1)
- Isosorbide (1)
- Kopplung (1)
- LAC (1)
- Liquid adsorption chromatography (1)
- Liquid adsorption chromatography at critical conditions (1)
- MALDI-TOF MS (1)
- MALDI-TOF mass spectrometry (1)
- MALDI-TOF-MS analysis (1)
- Maillard system 2-deoxy-D-ribose / methylamine (1)
- Main-chain liquid crystalline polyurethanes (1)
- Matrix-assisted laser desorption (1)
- Matrix-assisted laser desorption ionization time-of-flight mass spectrometry (1)
- Mesogenic unit (1)
- Metallocene catalysts (1)
- NP-HPLC (1)
- Nanostructure (1)
- Novolak (1)
- Oligomerization of N-methyl-2-hydroxymethyl(and hydroxyl[13C]methyl)pyrrole (1)
- Orthogonal chromatography (1)
- Perfluoralkylalkoxysilane (1)
- Poly(butylene terephthalate) (1)
- Poly(ether sulfone)s (1)
- Poly(ethylene terephthalate) (1)
- Poly(thio-ester)s (1)
- Polyazomethines (1)
- Polyester (1)
- Polyether (1)
- Polyolefins (1)
- Preparative HPLC (1)
- Primer on steel (1)
- Pull-off test (1)
- Pyrroles from pentoses and hexoses (1)
- Ring-Opening Polycondensations (1)
- Ring-opening polycondensation (1)
- SEC (1)
- SP-B (1)
- SP-C (1)
- Silicon compounds (1)
- Siloxysilsesquioxane (1)
- Silsesquioxanes (1)
- Size exclusion chromatography (1)
- Soft segments (1)
- Sols (1)
- Spherosilicate (1)
- Structure (1)
- Surface pressure (1)
- Surfactant proteins (1)
- Synthesis (1)
- Wet adhesion of alkyd melamine resin (1)
Investigations of Polymer Heterogeneity by Two-Dimensional HPLC, MALDI-TOF-MS and FTIR Coupling
(1995)
Liquid chromatography in combination with spectroscopic methods like matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOFMS) or nuclear magnetic resonance (NMR) spectroscopy is a powerful method to characterize silsesquioxanes and silsesquioxane mixtures. As new examples, the formation of silsesquioxyl-substituted silsesquioxanes [(n-octyl)7(SiO1.5)8]2O and [(n-octyl)7(SiO1.5)8O]2[(n-octyl)6(SiO1.5)8] as well as the cage rearrangement of octa-[(n-heptyl)silsesquioxane] to larger structur es [(n-heptyl)SiO1.5)]n up to n=28 are shown.
Chemical heterogeneities and molecular weight distributions of poly(ethylene oxide) (PEO)-co-polymethylene (PM) model oligomers, which are relevant to the synthesis of commonly used tensides, were investigated. For analytical characterization, the well-known principle of liquid adsorption chromatography at 'critical conditions' (LACCC) was modified. Near the critical conditions of adsorption of the PEO unit, e.g., at slight adsorption conditions of PM, the copolymers could be separated according to their PM chain length. The eluates were separated and single fractions of each peak were continuously transferred onto the MALDI target by means of a commercially available device. Simultaneously, the MALDI matrix solution was continuously added with a second pump. This procedure offers the possibility of the formation of homogeneous matrix-polymer textures. By MALDI-MS a complete characterization of the chemical composition (PEO and PM chain length) of each peak could be achieved. The obtained MALDI mass spectra of the eluates at different retention times could be used for the molecular weight calibration of the LAC system. In this way, an additional application of SEC, as in conventional 2D-chromatography, was avoided by using the MALDI method as quasi chromatographic separation