Filtern
Erscheinungsjahr
Dokumenttyp
- Vortrag (41)
- Zeitschriftenartikel (26)
- Beitrag zu einem Tagungsband (23)
- Posterpräsentation (5)
- Beitrag zu einem Sammelband (4)
- Forschungsbericht (4)
- Buchkapitel (1)
Schlagworte
- Sewage sludge ash (10)
- Elutionsverfahren (7)
- Resource recovery (7)
- Klärschlammasche (6)
- Phosphorus recovery (6)
- Column test (5)
- Critical raw materials (5)
- Leaching (5)
- Phosphorus (5)
- Batch test (4)
Organisationseinheit der BAM
Eingeladener Vortrag
- nein (41)
Leaching tests are fundamental tools for the assessment of long-term impact of contaminated waste materials on the soil-groundwater pathway. Experiments were carried out in the framework of standardization and validation of column percolation and batch test procedures, in particular concerning the stipulation of the experimental setup. The colloid release of column and batch experiments was compared and the influence of different column filling heights (12.5–50 cm) on the release of polycyclic aromatic hydrocarbons (PAH) from soil was studied, as well as the effect of varying contact times (2.5–16 h) on the release of chromium from construction and demolition (C&D) waste and municipal solid waste incineration (MSWI) bottom ash. The results indicate that filtration of the eluate, which is required for batch tests, does not always allow the simulation of the actual colloid amount in soil pore water. Medium column heights four times the inner diameter of the column seemed to provide reasonable equilibrium adjustment conditions and avoid major biodegradation. The release of chromium was only marginally affected by the contact time, varied between 0.115 and 0.150 mg/kg for demolition waste eluate at a liquid-to-solid ratio of approximately 5 L/kg.
Stir bar sorptive extraction (SBSE) and solid phase microextraction (SPME) are well-established sample preparation methods for the analysis of polycyclic aromatic hydrocarbons in aqueous samples. However, complex matrices especially characterized by slurry particles and dissolved organic matter (DOM) can hamper the extraction of PAH with both SBSE and SPME and lead to different results. Thus, we produced aqueous eluates from PAH-contaminated soils differing in particle size distribution and organic matter content and determined the PAH concentration in the eluates with both SBSE and SPME. Furthermore, we tested the influence of filtration on the PAH analysis. The excess finding of PAH with SBSE compared to SPME ranged from −16.6 to 24.5 %. The differences increased after filtration. We found a strong positive correlation of the excess finding to the total organic carbon content (TOC) and a negative one to the pH value. The results indicate that SBSE is less affected by complex matrices than SPME.