Filtern
Erscheinungsjahr
Dokumenttyp
- Zeitschriftenartikel (124)
- Posterpräsentation (33)
- Vortrag (22)
- Forschungsbericht (5)
- Beitrag zu einem Tagungsband (4)
- Beitrag zu einem Sammelband (1)
- Corrigendum (1)
- Dissertation (1)
- Forschungsdatensatz (1)
Schlagworte
- Mycotoxins (16)
- Food (10)
- Electrochemistry (8)
- Quality assurance (8)
- Zearalenone (8)
- ERM (7)
- LC-MS/MS (7)
- Mycotoxin (7)
- Deoxynivalenol (6)
- HPLC-MS/MS (6)
Organisationseinheit der BAM
- 1 Analytische Chemie; Referenzmaterialien (45)
- 1.7 Organische Spuren- und Lebensmittelanalytik (45)
- 1.6 Anorganische Referenzmaterialien (5)
- 1.2 Biophotonik (3)
- 4 Material und Umwelt (3)
- 6 Materialchemie (3)
- 6.3 Strukturanalytik (3)
- 1.1 Anorganische Spurenanalytik (2)
- 1.4 Prozessanalytik (2)
- 1.8 Umweltanalytik (2)
Eingeladener Vortrag
- nein (22)
Liquid chromatography coupled with tandem mass spectrometric detection has gained more importance for mycotoxin determination in recent years. In addition to instrumental improvements, the development of LC-MS-MS has also been a consequence of the availability of stable isotope internal standards, e.g., 13C-labelled mycotoxins. Thus, the LC-ESI-MS-MS method using a 13C15-deoxynivalenol internal standard as a state-of-the-art technique was selected as a reference procedure for an in-house method comparison study of the determination of deoxynivalenol (DON) in wheat materials. Alternative methods include LC-diode array detection, which is a frequently used routine procedure for DON-analysis, and gas chromatography after trimethylsilylation. For GC application, an electron capture detector and a negative chemical ionisation mass spectrometry detector were used, which have both been well described in the literature. The method comparison was conducted using t test statistics. Additionally, this study also calculates important method performance characteristics, including accuracy, linearity, limit of detection, limit of quantification, recovery, and variation coefficient. Furthermore, this is the first report of a GC-MS method for the determination of DON using a fully carbon-labelled 13C15-DON as an IS. The GC-MS using 13C15-DON as an IS has produced comparable results to the 13C-IS-LC-MS-MS reference method with a similar sensitivity. ECD detection was slightly less sensitive, but is also suited for DON analysis in wheat. Due to the high LOQ, the LC-DAD method seems highly applicable to the measurement of highly contaminated samples.
The aim of this study was to investigate the distribution of zearalenone in wheat kernels contaminated with this mycotoxin. Kernels from a sample of a wheat harvest affected by Fusarium culmorum were sorted into six groups according to their visual attributes. Milled portions of these groups were analysed by high-performance liquid chromatography with fluorescence and diode array detection. The clean-up was performed with an immunoaffinity column after methanol/water (4:1, v/v) extraction. The zearalenone content of the unsorted kernel fraction was 74 µg/kg. The group of healthy-looking kernels was contaminated with only 6 µg/kg of zearalenone. The groups of kernels that appeared shrunken and chalky white, damage routinely caused by Fusarium, were contaminated with 170 and 117 µg/kg, respectively. A remarkably high level of zearalenone contamination, 2,184 µg/kg, was observed for the group of reddish kernels. An association between the presence of the red pigment aurofusarin and high levels of zearalenone was found. Therefore, this pigment may be used as a marker of high zearalenone content.
Distribution of Trichothecenes, Zearalenone, and Ergosterol in a Fractionated Wheat Harvest Lot
(2008)
To investigate possible co-occurrences of type B trichothecenes and zearalenone within a Fusarium culmorum-infected wheat harvest lot, kernels were fractionated into six groups by visual criteria. The Fusarium-damaged kernels were subdivided into white, shrunken, and red kernel groups, and the remaining kernels were sorted into healthy, black spotted, and nonspecific groups. The distribution patterns of nivalenol, deoxynivalenol, zearalenone, and ergosterol were determined for possible correlations. Significant correlations between the distribution patterns were found for the mycotoxins and ergosterol for the grouped kernels (r = 0.997-0.999, p < 0.0001). Additionally, remarkably outstanding levels of nivalenol (24-fold more than the mean at 1.16 mg/kg), deoxynivalenol (27-fold more than the mean at 0.16 mg/kg), zearalenone (25-fold more than the mean at 77 µg/kg), and ergosterol (17-fold more than the mean at 13.4 mg/kg) were found in the red kernel group. Further, detailed mycotoxin and ergosterol analyses were carried out on various segments (kernel surface, conidia, bran, and flour) of the red kernels. However, the mycotoxin and ergosterol distribution profiles revealed nonsignificant correlations for these kernel segments, with the exception of deoxynivalenol and nivalenol, which were moderately correlated (r = 0.948, p = 0.035).
High-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) can be used for simultaneous quantification of various mycotoxins in contaminated food samples. Therefore, multi-mycotoxin methods have been developed in the last couple of years. To enlarge these methods for further analytes, we have developed a LC-MS/MS method for the quantification of the mycotoxin aurofusarin. Additionally, further LC-MSn experiments were performed to demonstrate the fragmentation pattern of aurofusarin. Applicable multiple reaction monitoring (MRM) transitions of aurofusarin were found and optimized by parameter variation of the tandem mass spectrometer. The applicability of the developed method was tested by analysis of naturally contaminated wheat.
For more than 110 years, BAM has been producing reference materials for a wide range of application fields. With the development of new analytical methods and new applications as well as continuously emerging more stringent requirements of laboratory accreditation with regard to quality control and metrological traceability, the demand and requirements for reference materials are increasing. This trend article gives an overview of general developments in the field of reference materials as well as developments in selected fields of application in which BAM is active. This includes inorganic and metal analysis, gas analysis, food and consumer products, and geological samples. In addition to these more traditional fields of application, developments in the areas of optical spectroscopy, particulary fluorescence methods, and nanomaterials are considered.
The article "Development of certified reference materials for the determination of cadmium and acrylamide in cocoa" was originally published in the journal "Analytical and bioanalytical chemistry" Online First without Open Access. After publication in volume 412, issue 19, page 4659–4668, the authors decided to opt for Open Choice and to make the article an Open Access publication. Therefore, the copyright of the article has been changed to ©The Author(s) 2021 and the article is forthwith distributed under the terms of the Creative Commons Attribution 4.0 International License.
Since 1 January 2019 a maximum content of 0.6 mg kg−1 cadmium (Cd) in cocoa powder sold to the final consumer or as an ingredient in sweetened cocoa powder sold to the final consumer (drinking chocolate) is set by the Commission Regulation (EU) No. 488/2014. Monitoring compliance with the specified limit value requires analytical measuring methods and reference materials for quality control. However, suitable certified reference materials intended for quality assurance and quality control purposes are still lacking. Therefore, three cocoa reference materials (ERM®-BD513, ERM®-514 and ERM®-515) were developed according to the requirements of ISO 17034 and the recommendations of ISO Guide 35. The whole process of reference material development, including material preparation, assessment of homogeneity and stability, characterisation and value assignment is presented. The assignment of the certified mass fractions was based upon an interlaboratory comparison study involving 19 expert laboratories for Cd and 12 laboratories for acrylamide. The certified mass fractions and expanded uncertainties (k = 2) of the reference materials were (0.181 ± 0.009) mg kg−1 Cd (ERM®-BD513), (0.541 ± 0.024) mg kg−1 Cd (ERM®-BD514) and (0.690 ± 0.029) mg kg−1 Cd (ERM®-BD515). Acrylamide contents are given for information.