Oxidative degradation processes of tetrabromobisphenol A (TBBPA), a brominated flame retardant (BFR) in wood, plastics and electronics, were investigated by electrochemistry (EC) coupled online to electrospray ionization mass spectrometry (ESI/MS). Oxidative phase I and II metabolites production was achieved using an electrochemical flow-through cell equipped with a boron doped diamond electrode. Structural elucidation and prediction of oxidative metabolism pathways of TBBPA according to type II ipso-substitution were based on retention time, m/z ratio in negative mode and fragmentation pattern. Using the data obtained through high resolution MS analysis and the identification of single electron transfer (SET) as the initial step of a two-electron oxidation provided the necessary information to propose a mechanism for the electrochemical oxidation of TBBPA. Oxidation reactions involving aromatic hydroxylation and β-scission were the main degradation observed when studying the electrochemical behavior of TBBPA. Computational chemistry experiments using density functional theory (DFT) allowed to identify mono-hydroxylated reaction intermediate and dismissed the mechanism involving two concurrent hydroxylation. TBBPA oxidation products were compared to known metabolites of its biological and environmental degradation confirming the ability of electrochemistry to simulate β-scission reactions.
A systematic series of industrial-relevant polystyrene-based anion exchange resins that are functionalized with hydro- or fluorocarbon chains are compared regarding their adsorption behavior toward perfluorocarboxylic acids (PFCA) in respect to their charge, chain length, and type of chain. The results clearly show the dominance of electrostatic interactions in the adsorption process as uncharged adsorber materials showed no adsorption at all. In contrast, the charged adsorber materials showed in general a PFCA removal of 80% to 30% over the experiment depending on effluent fraction.
Unexpectedly, for perfluorobutanoic acid (PFBA) the highest removal rate is found with consistently >90%. Despite observing significant benefits in the adsorption of PFCA for fluoroalkylated adsorbers in comparison to their non-fluorinated counterparts, this effect of fluoroalkylation is comparatively small and can not be clearly attributed to fluorophilic interactions between the fluoroalkyl chains. These findings help clarifying that the introduction of fluorocarbon moieties in adsorber materials is not necessary in order to remove fluorocarbon molecules from the environment.
Data file (RData) containing measurement data recorded during the production process of the Certified Reference Material BAM-A001 containing Polycyclic Aromatic Hydrocarbons (PAH) in olive oil. The data can be most conveniently openend using the Shiny-App eCerto which is accessible at https://www.bam.de/eCerto.
Demonstrating competency and equivalence for the measurement capacity of contaminants and nutrients in primary foodstuffs is a priority of the OAWG 10-year strategy for Track A core comparisons. Such measurements have posed significant challenges for reference material producers and calibration service providers. This key comparison (KC), under the topic of “non- polar analyte in high carbohydrate food matrix: trans-Zearalenone (trans-ZEN) in maize powder” , was a sector of the model system selected to align with this class within the OAWG strategy. Evidence of successful participation in formal, relevant international comparisons is needed to demonstrate the Calibration and Measurement Capabilities (CMCs) of national metrology institutes (NMIs) and designated institutes (DIs).
17 NMIs and DIs participated in the Track A KC CCQM- 168 “non-polar analyte in high carbohydrate food matrix: trans-ZEN in maize powder” . Participants were requested to evaluate the mass fraction (μg/kg) of trans-ZEN in maize powder material. Methods like liquid-liquid extraction and SPE were applied in the pre-treatment, and HPLC-MS/MS and HPLC-FLD were used for detection by the participants. The mass fractions for trans-ZEN were in the range of (91.8 to 169) μg/kg with standard uncertainties of (1.5 to 24.7) μg/kg, and corresponding relative standard uncertainties from 1.5% to 14.6%. Two labs, INTI and BAM were excluded from the KCRV evaluation. INTI result was identified as an outlier and confirmed their method had insufficient specificity. For BAM the calibration approach they used does not meet the CIPM traceability requirements. The other 15 labs included in the calculation of the consensus KCRV all agreed within their standard uncertainties. Hierarchical Bayes was used as estimators in calculating KCRV and standard uncertainty.
Successful participation in CCQM-K168 demonstrates the measurement capabilities in determining mass fraction of organic compounds, with molecular mass of 100 g/mol to 500 g/mol, having low polarity pKow < -2, in mass fraction range from 1 μg/kg to 1000 μg/kg in a high carbohydrate food matrix.
Mykotoxine in Lebensmitteln stellen weltweit Probleme dar, Zearalenon in Speiseöl ist ein solches. Neue Hydrazinbasierte Analyseverfahren können jetzt helfen, den EU-Grenzwert besser zu kontrollieren. Aber auch die Strukturaufklärung von Transformationsprodukten und verlässliche Kalibrierstandards sind aktuelle Herausforderungen.
Alternariol (AOH) and Alternariol monomethylether (AME) are two secondary metabolites of Alternaria fungi which can be found in various foodstuffs like tomatoes, nuts and grains. Due to their toxicity and potential mutagenic activity, the need for the development of high-throughput methods for the supervision of AOH- and AME-levels is of increasing interest. As the availability of both native and labelled AOH and AME analytical standards is very limited we herein wish to present a novel concise approach towards their synthesis employing a ruthenium-catalyzed ortho-arylation4 as the key step.
Polycyclic aromatic hydrocarbons (PAH) can contaminate plastic and rubber parts of consumer products including toys. PAH are present as impurities in some of the raw materials used for production of such articles, particularly in extender oils and in carbon black. Because PAH have negative effects on health (e.g. carcinogenic), standard methods have been developed in several countries to control PAH in consumer/toy products, mainly based on gas-chromatography mass-spectrometry (GC-MS).
To protect consumers from hazards of PAH, national regulations and maximum levels are already in force, for example in Germany. Recently, maximum levels for 8 PAH compounds (benz[a]anthracene, chrysene, benzo[b]fluoranthene, benzo[k]fluoranthene, benzo[j]fluoranthene, benzo[e]pyrene, benzo[a]pyrene and dibenz[a,h]anthracene) have been established by EC-regulation 1272/2013. This resulted in an urgent need for certified reference materials (CRM) to meet the requirements of the EC-regulation (1 mg/kg for each PAH compound in consumer products and 0.5 mg/kg in toys, respectively).
In 2016 BAM started a project to certify the PAH mass fractions in a toy CRM to fill the current gap of available reference materials. Several different toys from retailers were screened to obtain a real-life material representing PAH mass fractions in the range of the EC-maximum level. The finally selected material (rubber balls for children) was prepared and characterized with respect to homogeneity and stability of 18 PAH. The extension to other health-relevant PAH compounds, e.g. indeno[1,2,3-cd]pyrene and benzo[ghi]perylene, will increase the applicability of the CRM for costumers, e.g. from industry, conformity assessment bodies and private testing laboratories.
The poster will present the current status of the ongoing CRM project including preparation of the candidate material and results from homogeneity and stability studies. In addition, first results of a joint German-Chinese interlaboratory comparison study will be shown.