Recently, first analyses of single sub-micrometre particles, embedded in liquid droplets, by inductively coupled plasma optical emission spectrometry (ICP-OES) with a size-equivalent detection limit of several hundred nanometres were reported.1,2 To achieve lower detection limits which might allow for the analysis of particles in the nanometre size range a more sensitive technique such as mass spectrometry (MS) is required. Various modifications of particle delivery and data acquisition systems commonly used were carried out to install a setup adequate for ICP-MS detection. These modifications enabled us to supply droplets generated by a commercial microdroplet generator (droplet size: 3040 µm) with nearly 100% efficiency and high uniformity to the ICP. Analyses were performed using both standard solutions of dissolved metals at concentrations of 1 (Ag), 2 (Au), 5 (Au), or 10 (Cu) mg L-1 and highly diluted suspensions of gold and silver nanoparticles with sizes below 110 nm. In doing so, detection efficiencies of 10-6 counts per atom could be achieved while size-related limits of quantification were found to be 21 nm and 33 nm for gold and silver, respectively. Furthermore, the advantages of utilizing microdroplet generators vs. conventional nebulizers for nanoparticle analyses by ICP-MS are discussed.
Single-particle inductively coupled plasma mass spectrometry (sp-ICP-MS) has become an effective tool for the detection and quantification of inorganic nanoparticles (NPs). While sizing of NPs suspended in water is relatively straightforward by sp-ICP-MS, accurate mass quantification of NPs in complex media, such as consumer products and natural systems still remains a challenge. When NPs are suspended in a complex medium, the matrix may affect the analyte sensitivity and lead to inaccurate NP sizing. Here, we investigate the use of an online microdroplet calibration system to size NPs in a single step. In this setup, microdroplets—which are used as the calibrant to determine elemental sensitivities—and nebulized NP-containing solutions are introduced concurrently into the ICP via a dual-inlet sample introduction system. Because calibrant microdroplets and analyte NPs experience the same plasma conditions, both the microdroplets and the NPs are subjected to the same matrix-related signal enhancement or suppression. In this way, the microdroplet calibration standards are automatically matrix matched with the NP-containing solution. The online microdroplet calibration system is combined with an ICP-TOFMS instrument for simultaneous measurement of multiple elements in microdroplets and NPs. We investigate the ability of online microdroplet calibration to compensate for matrix effects through a series of experiments, in which Ag and Au NPs are measured with variable plasma-sampling positions, varying concentrations of HCl and HNO3, varying concentrations of single element solutions, and high concentrations of a salt matrix, i.e. phosphate buffered saline (PBS). Through these experiments, we demonstrate that the online microdroplet calibration strategy provides a matrix-independent mass quantification of analyte NPs in the presence of several established types of matrix effects, including acid effects, space-charge effects, and ionisation suppression. In results presented here, we focus on the size determination of the NPs.
Within the scope of a DIN INS project, a flash thermography round robin test that evaluates reliability, comparability, and efficiency of different testing situations was organized. The results give information about the detectability of defects, e.g. depending on their size and depth, the evaluation methods and the materials used. Besides, the influences of equipment and parameters used by the participants on the results were analysed. All of the quantitative results as well as the feedback given by the participants will be presented in a DIN committee in order to contribute to a flash thermography standard.
Within the scope of a DIN INS project, a flash thermography round robin test that evaluates reliability, comparability and efficiency of different testing situations is organized. The results give information about the detectability of defects e.g. by their size and depth, the evaluation method and by the materials used. Besides, the influence of equipment and parameters used by the participants on the results were analysed. All of the quantitative results as well as the feedback given by the participants will be presented in a DIN committee in order to contribute to a flash thermography standard.
A round robin test on flash thermography was organized within the scope of a standardization research project. This test gives information on reliability, comparability and efficiency of different testing situations. Data recorded on metal and CFRP test specimens with flat bottom holes (FBH) were analysed by evaluating the detectability and by calculating the signal-to-noise ratio (SNR) of the defect signatures as a function of defect parameters. For the investigation of the influence of material properties on the spatial resolution as well as on penetration depth, test specimens made of steel and copper with crossed notches and a notch ramp were constructed and investigated. Here, the minimum resolvable notch distance and the maximum detectable depth of the ramp were analysed.
Probability of detection analysis of round robin test results performed by flash thermography
(2016)
Within the scope of a standardisation research project, a flash thermography round robin test that evaluates reliability, comparability and efficiency of different testing situations was performed. Data recorded at metal test specimens with flat bottom holes (FBHs) were analysed by calculating the signal-to-noise ratio (SNR) of the defect signatures in the thermograms as well as in the phase images as a function of defect parameters. A new multi-parameter probability of detection (POD) model was developed, where an â versus a continuous signal analysis was based on the linear relationship between the SNR and a multi-parameter a. This linear relationship was verified by comparison to data obtained from an analytical model that is considering lateral thermal heat diffusion as well as to data obtained by numerical simulation. The resulting POD curves for the thermograms and phase images give an estimation for the detectability of the FBHs with known geometry in steel using different equipment and obtained by different participants. By comparing the SNRs of FBHs with similar geometries, this POD model was transferred to aluminium and copper as well.
Im Rahmen des INS-Projekts „Durchführung von Ringversuchen zur Normung und Standardisierung der aktiven Thermografie mit Blitzlichtanregung“ wurden Ringversuche durchgeführt, die die Zuverlässigkeit, Vergleichbarkeit und Effektivität der Blitzthermografie für unterschiedliche Prüfprobleme nachweisen sollten. Weiterhin sollten diese Untersuchungen als Methodenvalidierungsstudie die Richtigkeit und Präzision der Blitzthermografie nachweisen und Vergleichsinformationen unterschiedlicher Geräteausstattungen liefern. Im Normausschuss NA 062-08-27 AA „Visuelle und thermografische Prüfung“ des DIN werden die Ergebnisse die Erarbeitung eines Normentwurfs zur Blitzthermografie unterstützen. In diesem Beitrag werden die Ringversuche beschrieben und ausgewählte Ergebnisse präsentiert.