Filtern
Dokumenttyp
- Beitrag zu einem Tagungsband (2)
- Vortrag (1)
Sprache
- Englisch (3)
Referierte Publikation
- nein (3)
Schlagworte
- LiDAR (3)
- NDT (3)
- Bridge (2)
- Laserscanner (2)
- Bridge inspection (1)
- Brücken (1)
- Zerstörungsfreie Prüfung (1)
Eingeladener Vortrag
- nein (1)
With the mandatory introduction of the May 2011 directive for reassessment of bridges in Germany, the administrations of the federal and state governments have the duty to prove the stability of their bridge stock. Verification of bridge stability will be realized with consideration of the newly increased traffic loads. Particularly in older bridges, the verification can only be achieved if calculative surplus load capacity of the original structural design is taken into account in the recalculation. One option for considering these reserves is the exact determination of the dead weight of the bridge. Within this case study, it will be demonstrated how the problem can be practically solved.
In order to determine the dead weight of a concrete bridge, its volume has to be calculated. as a first step, a 3D laser scanner is used to record the internal geometry of a hollow box bridge girder. For the determination of the thickness of the concrete member, the non-destructive technique ultrasonic echo is applied. The construction must be segmented in approximately equidistant parts in order to be able to carry out an economic and efficient investigation. The description of the segmentation of the point cloud, carried out in a 2D model, was presented in the first part of the publication. The subject of this presentation is the merging of 2D cross sections into a 3D model, from which the weight of the bridge can be calculated.
With the mandatory introduction of the directive for recalculation of bridges in May 2011 in Germany, the administrations of the federal and state governments have a duty to demonstrate the stability of their bridge inventory. The requisite verification will be realized under consideration of the new increased traffic loads on the construction, in a four-step process. Particularly in older bridges the verification succeeds only using the computational resources of the original structural design. One option these reserves to be considered is the exact determination of the dead weight of the bridge. Since the existing as-built documents of the construction often digress significantly from the real dimensions, there are two options to resolve the issue. In addition to the technically very complicated and relatively expensive method of weighing the construction, the calculation can also be done indirectly through a combined process of hotogrammetric measurement and non-destructive testing. On a practical case study will be demonstrated how the solution of this problem can succeed. For this is done in the first step to scan in detailed the inner topography of a part of the construction by a 3D laser scanner. The results of these tests are compared with the existing stock plans of the building. The aim of this study is to determine the dead weight of structure. Therefore, in the first part of this work sectional plans were extracted of the technical drawing and the point cloud to calculate the area of the interior. Based on the calculated areas in the sectional planes, the volume calculation should take place in the next step.
With the mandatory introduction of the directive for recalculation of bridges in May 2011 in Germany, the administrations of the federal and state governments have a duty to demonstrate the stability of their bridge inventory. The requisite verification will be realized under consideration of the new increased traffic loads on the construction, in a four-step process. Particularly in older bridges the verification succeeds only using the computational resources of the original structural design. One option these reserves to be considered is the exact determination of the dead weight of the bridge. Since the existing as-built documents of the construction often digress significantly from the real dimensions, there are two options to resolve the issue. In addition to the technically very complicated and relatively expensive method of weighing the construction, the calculation can also be done indirectly through a combined process of photogrammetric measurement and non-destructive testing. On a practical case study will be demonstrated how the solution of this problem can succeed. For this is done in the first step to scan in detailed the inner topography of a part of the construction by a 3D laser scanner. The results of these tests are compared with the existing stock plans of the building. The aim of this study is to determine the dead weight of structure. Therefore, in the first part of this work sectional plans were extracted of the technical drawing and the point cloud to calculate the area of the interior. Based on the calculated areas in the sectional planes, the volume calculation should take place in the next step.