There is growing interest in quantifying microplastics in environmental samples. This application note presents a thermal extraction desorption-gas chromatography/mass spectrometry (TED-GC/MS) method that is well suited to automation and increased sample throughput. The method is also able to detect all particle sizes in the sample as long as the limit of detection (LOD) is reached and allows analysis of larger samples of 15 to 25 mg or more. Samples were decomposed by thermogravimetric analysis (TGA), and the gaseous decomposition products were trapped on a solid-phase sorbent, followed by thermal desorption‑gas chromatography/mass spectrometry (TD-GC/MS) using an Agilent 5977B GC/MSD coupled to an Agilent 7890B GC. Target microplastic particle (MP) polymers were identified in environmental samples including surface water, finished compost, house dust, and drinking water. Quantification of MP polymers in environmental samples provided LODs of 0.06 to 2.2 μg, allowing the detection of MPs in trace amounts with sample weights of up to 1 g. Method repeatability was adequate for reliable quantification with RSDs of approximately 6 to 12%.
As global demand for polymer products increases, so does the potential amount of leakage into the environment, known as macroplastic (> 1,000 µm) and microplastic particles (MP, 1 - 1,000 µm). To date, the environmental and health consequences are unclear and unpredictable, so robust MP monitoring data are needed to identify the sources, pathways and fate of these particles. Therefore, we developed the thermoanalytical method TED-GC/MS (thermal extraction desorption - gas chromatography/mass spectrometry), which uses polymer-specific thermal decomposition products for the detection of MP in environmental samples. It allows fast identification and the determination of MP mass contents, which is crucial for assessing of their potential effects and thus for legislation and monitoring.
For a better understanding of the TED-GC/MS, this presentation will provide the first methodological insights into systematic assessments of TED-GC/MS performance for MP detection in different environmental model matrices. Results of MP determination from real samples will underline the presentation and aspects of practical application will be addressed.
To harmonise the method, it is essential to assess different analytical performance parameters (e.g. recovery, signal quality or limit of detection, LOD) to ensure comparability of data. For this purpose, standard addition of different aquatic (e.g. suspended particulate matter, limnic sediment, activated sludge) and terrestrial samples (e.g. agricultural soil) were performed with non-biodegradable standard polymers (polyethylene, PE; polyethylene terephthalate, PET; polypropylene, PP; polymethyl methacrylate, PMMA; polystyrene, PS; styrene-butadiene rubber, SBR) as well as biodegradable polymers (polybutylene adipate terephthalate PBAT; polylactide, PLA) and analysed by TED-GC/MS. These results were then compared with the measurements of the neat polymers without matrix.