Filtern
Erscheinungsjahr
Dokumenttyp
- Zeitschriftenartikel (73)
- Vortrag (37)
- Beitrag zu einem Tagungsband (13)
- Posterpräsentation (7)
- Beitrag zu einem Sammelband (4)
- Forschungsbericht (1)
Schlagworte
- Metrology (8)
- Traceability (7)
- Calibration (5)
- Uncertainty (5)
- Copper (4)
- CCQM (3)
- Chemical analysis (3)
- Gas analysis (3)
- Zinc (3)
- Carrier gas hot extraction (2)
Organisationseinheit der BAM
- 1 Analytische Chemie; Referenzmaterialien (14)
- 1.4 Prozessanalytik (11)
- 1.6 Anorganische Referenzmaterialien (3)
- 1.1 Anorganische Spurenanalytik (2)
- 1.0 Abteilungsleitung und andere (1)
- 1.2 Biophotonik (1)
- 1.7 Organische Spuren- und Lebensmittelanalytik (1)
- 4 Material und Umwelt (1)
- 4.2 Material-Mikrobiom Wechselwirkungen (1)
- 5 Werkstofftechnik (1)
Eingeladener Vortrag
- nein (37)
Isotope amount ratios of krypton were measured on subsamples from one large batch of high purity krypton separated from the atmosphere. Synthetic mixtures of enriched krypton isotopes were used to calibrate the measurements with small uncertainties. The result is a primary isotopic gas standard (PIGS) IRMM-2030 with certified values for isotope ratios, isotopic composition, and molar mass of krypton with small combined uncertainties uc, evaluated according to the ISO/BIPM Guide (GUM). It is commercially available from IRMM-Geel or from MESSER (Duisburg, D). The certified krypton isotope amount ratios in the PIGS IRMM-2030 are as follows: n(78Kr)/n(84Kr)=0.006 232 5(55), n(80Kr)/n(84Kr)=0.040 107(17), n(82Kr)/n(84Kr)=0.203 43(12), n(83Kr)/n(84Kr)=0.201 79(11), and n(86Kr)/n(84Kr)=0.303 205(59) with expanded uncertainty U=kuc and coverage factor k=2. The molar mass of Kr in this sample is M(Kr)=83.798 02(16) g/mol. These values are in good agreement with published measurements of atmospheric krypton but have smaller combined uncertainties and are calibrated by means of synthetic isotope mixtures. The values of the PIGS are traceable to the SI. Measurements of isotope amount ratios of krypton in other samples can be linked to SI using this PIGS.
Problems with understanding, explaining and communication of the present definition of primary method of measurement are described and amendments put forward for discussion. The conclusion is drawn that in many cases more attention should be given to the measurement result and its uncertainty statement, rather than to a method. Some cases are discussed where methods might have a fundamental characteristic that other methods do not have, a condition for the epitheton primary'.