Commercially available absorption filters (Schott BG18 and BG36) were investigated with respect to their single- and
multi-pulse ablation threshold using laser pulses from a Ti:Sapphire laser in the range between 30 and 340 fs. It could be
observed, that the threshold fluence decreases for shorter pulse durations. The similarity of the measured multi-pulse
threshold fluences with those of undoped glass material (around 1 J/cm^2 for a pulse duration of 30 fs) suggests that, for
very short pulses, the threshold is independent on the doping level and therefore, linear absorption does not significantly
contribute to laser-induced damage. For >100 pulses per spot and all pulse durations applied, the threshold fluences
saturate. This independence on the number of applied pulses leads to technically relevant damage threshold values.
A detailed diagnostic study of the interaction of nanosecond laser pulses from the near-ultraviolet into the near-infrared
wavelength range with various types of contemporary and ancient parchments is presented. The advantages of laser
cleaning due to the absence of chemical agents, spectroscopic selectivity, micro-precision, computer-aided handling can
only be verified when physico-chemical diagnostics guarantee destructionless processing. Scanning Electron Microscopy
(SEM) data are correlated with morphological changes in dependence on the laser fluence and wavelength. The
question, to what extent the chemical degradation of collagen is affected by various laser treatment parameters, could be
resolved by Transmission Electron Microscopy (TEM) of collagen fibres collected from the outermost laser-exposed
surface layer. It is also shown how Diffuse Reflectance Infrared Fourier Transform Spectroscopy (DRIFT), and
Pyrolysis Capillary Gaschromatography (PY-CGC) can be employed in the chemical diagnostics of laser cleaning of
parchment. This study suggests that the ageing status of parchment artefacts plays a major role in assessing the laser
cleaning limits.