Filtern
Erscheinungsjahr
Dokumenttyp
Schlagworte
- Neutron imaging (7)
- Neutron tomography (7)
- Computed tomography (4)
- Fuel cell (4)
- Neutron radiography (4)
- Tomography (4)
- Computertomographie (3)
- Neutronen-Tomographie (3)
- Phase distribution (3)
- Brennstoffzellen (2)
- Catalyst (2)
- Computer-Tomographie (2)
- Darkfield imaging (2)
- Electron tomography (2)
- Elektronen-Tomographie (2)
- Geometrical effect (2)
- Hydrogen diffusion (2)
- Hydrogen embrittlement (2)
- Magnetic domains (2)
- Neutronentomographie (2)
- Reconstruction algorithm (2)
- Rectangular cross-section (2)
- Rekonstruktionsalgorithmen (2)
- Torsion (2)
- Water management (2)
- X-ray compton scattering (2)
- X-ray imaging (2)
- 4D tomographic data (1)
- Backlighting (1)
- Blister (1)
- Bragg-edge (1)
- Bragg-edge imaging (1)
- Brennstoffzelle (1)
- Cells (1)
- Compression effect (1)
- Comptonstreuung (1)
- Debye-Waller-Faktor (1)
- Diffraction contrast neutron imaging (1)
- Diffusion (1)
- Digital detector array (1)
- Elektronentomographie (1)
- Fiber composites (1)
- Full-field phase tomography (1)
- Gas diffusion layer (1)
- Gas evolution (1)
- Grating interferometry (1)
- Hydrogen (1)
- Imaging (1)
- In situ (1)
- In-Situ-Radiologie (1)
- Instrumentation for neutron sources (1)
- Iron (1)
- Laser powder-bed fusion (1)
- Lithium-ion battery (1)
- Manifold stack (1)
- Materialcharakterisierung (1)
- Metal foam microstructure (1)
- Multi-energy CT (1)
- Neutron computed tomography (1)
- Neutron detectors (cold, thermal, fast neutrons) (1)
- Neutronen-Radiographie (1)
- Neutronenlaminographie (1)
- Nneutron imaging (1)
- Non-destructive testing (1)
- PEM fuel cell (1)
- Phase transformation (1)
- Polymer electrolyte membrane fuel cell (1)
- Polymer electrolyte membrane fuel cell (PEMFC) (1)
- Preferential orientation (1)
- Primary Battery (1)
- Radiography (1)
- Radiology (1)
- Reconstruction algrorithm (1)
- Room-temperature (1)
- Röntgen-Kanten-Tomographie (1)
- Shearing gratings (1)
- Spectral CT (1)
- Steel (1)
- Stromdichtemessung (1)
- Synchrotron (1)
- Synchrotronstrahlung (1)
- Talbot-Lau (1)
- Talbot-Lau interferometer (1)
- Talbot-Lau neutron tomography (1)
- Texture (1)
- Thermal runaway (1)
- Three-dimensional data quantification (1)
- Tomographic reconstruction (1)
- Tomographische Rekonstruktionsalgorithmen (1)
- Two-phase flow (1)
- Wassermanagement (1)
- Water transport (1)
- X-ray CT (1)
- X-ray radiography (1)
- X-ray tomography (1)
- Zerstörungsfrei (1)
- cold neutrons (1)
- iron embrittlement (1)
- neutron imaging (1)
- neutron instrumentation (1)
Organisationseinheit der BAM
Neutron tomography was applied to study the 3D water distribution in full polymer electrolyte membrane fuel cell (PEMFC) stacks. The water distribution after switch-off of the fuel cell was analyzed over a period of 36 h. We found a slowly increasing water amount in the fuel cell, but only few changes within a time period of 5 h, which is about the time necessary for neutron tomography. In this way, the requirement for successful tomography was obtained. It is demonstrated how the quasi in-situ tomography technique enables us to study the water content in individual flow field channels of three-fold stacks. Flow field as well as stack design issues are addressed by this visualization method showing weak points due to a non-uniform water distribution that can be identified by means of neutron imaging.
Aufgrund des hohen Wirkungsgrades und der vielfältigen Einsatzmöglichkeiten können Brennstoffzellen einen wichtigen Beitrag zur zukünftigen Energieversorgung leisten. Für die Optimierung der Brennstoffzellentechnik ist es erforderlich, die während des Zellbetriebs ablaufenden Prozesse zu verstehen und exakt zu charakterisieren. Ein ausbalanciertes Wassermanagement ist die Grundlage für die optimale Leistungsfähigkeit einer wasserstoffbetriebenen Zelle. Das während des Betriebs entstehende Wasser muss die Membran ausreichend befeuchten, um deren Protonenleitfähigkeit aufrechtzuerhalten. Andererseits behindern zu große Wasseransammlungen in der Zelle die Gaszufuhr durch die porösen Materialien sowie in den Kanälen der Gasverteilerstrukturen. Alterungsphänomene einzelner Zellkomponenten können die Verteilung der Wasseransammlungen und somit das Wassermanagement empfindlich stören und so die Leistungsfähigkeit der Brennstoffzelle herabsetzen. Zur Analyse der Wasserverteilung werden zerstörungsfreie, bildgebende Methoden, wie die Ex-situ-Neutronentomografie und die In-situ-Synchrotronradiografie, eingesetzt. Diese Methoden können während des Brennstoffzellenbetriebs mit weiteren Messverfahren, beispielsweise der ortsaufgelösten Stromdichtemessung, kombiniert werden. Auf diese Weise werden einzelne Komponenten, wie zum Beispiel die Gasdiffusionsschichten, charakterisiert.
Auf Grund des hohen Wirkungsgrades und der vielfältigen Einsatzmöglichkeiten stellen Brennstoffzellen sowie Brennstoffzellenverbünde eine vielversprechende Energiequelle dar. Daher ist es wichtig, die Prozesse während des Betriebs einer Brennstoffzelle exakt charakterisieren zu können, um diese im nächsten Schritt zu optimieren.
So ist ein ausbalanciertes Wassermanagement in einer mit Wasserstoff betriebenen Zelle ausschlaggebend für ihre Leistungsfähigkeit. Für eine dauerhafte Leistungsfähigkeit muss das entstehende Wasser die Membran feucht halten, um so die Protonenleitfähigkeit aufrecht zu erhalten. Zu viel Wasser kann jedoch die Gaszufuhr durch die porösen Materialien in Richtung Membran verhindern.
Alterungsphänomene der einzelnen Komponenten können dieses sensible Wassermanagement stören und so die Leistungsfähigkeit einer Brennstoffzelle
herabsetzen. Zum tieferen Verständnis der Wasserverteilung werden zerstörungsfreie Methoden, wie zum Beispiel die ex situ Neutronentomografie oder die in situ Synchrotronradiografie eingesetzt. Letztere Methode kann während des Brennstoffzellenbetriebs in Kombination mit weiteren Messmethoden, wie der ortsaufgelösten Stromdichtemessung, eingesetzt werden. So können einzelne Brennstoffzellenkomponenten, wie die Gasdiffusionsschichten, charakterisiert werden.
Ein effektives Wassermanagement ist ein wichtiger Aspekt in der Entwicklung von Brennstoffzellen hinsichtlich Langzeitstabilität und Optimierung der Leistungsfähigkeit. Eine zentrale Rolle spielt dabei die Gasdiffusionslage, die für die gleichmäßige Verteilung der Reaktionsgase auf die elektrochemisch aktive Schicht (Katalysator) sorgen soll. In diesem Beitrag werden gemeinsame Forschungsaktivitäten des Helmholtz-Zentrums Berlin für Materialien und Energie (Entwicklung bildgebender Verfahren) sowie des Zentrums für Sonnenenergie- und Wasserstoff-Forschung (ZSW, Entwicklung von Brennstoffzellen) vorgestellt. Im Rahmen dieser Kooperation werden die Entstehung, die Verteilung und der Transport von flüssigem Wasser, kurz das Wassermanagement, unter Betriebsbedingungen untersucht. Mittels Synchrotronradiografie und -tomografie werden kleinste Wassercluster in der Gasdiffusionslage detektiert. Die gewonnenen Erkenntnisse dienen der Modifikation und einer gezielten Auswahl der eingesetzten Materialien.
In-situ-Neutronenradiografie wird erfolgreich eingesetzt, um flüssiges Wasser in Niedertemperatur-PEM-Brennstoffzellen während des Betriebs zerstörungsfrei abzubilden und das sogenannte Wassermanagement eine der größten Herausforderungen der Entwicklung durch Anpassung der Materialeigenschaften zu optimieren. Dabei werden die besonderen Eigenschaften der Neutronen genutzt, die metallische Bauteile relativ leicht durchdringen, während selbst kleine Wassermengen durch ihre starke Streuung leicht nachweisbar sind. Die relativ langen Messzeiten für die Neutronentomografie werden durch den Betrieb der Zelle im angehaltenen Zustand realisierbar, sodass die dreidimensionale Wasserverteilung darstellbar wird.
Water transport in an operating PEM fuel cell was investigated with synchrotron X-ray radiography with a spatial resolution of 3 µm and a temporal resolution of 5 s. This method allows for the detection of water accumulations with less than 10 µm diameter. We demonstrate that synchrotron X-ray imaging can dramatically expand the possibilities of imaging with high spatial and time resolution, especially as a complement to neutron radiography. Water transport processes from the first appearance of small water accumulations in the gas diffusion layer to their transport into the channel system were analysed in situ. Correlations between local effects such as water formation and operating conditions of the whole system, e.g. power variations, were found. A recently described eruptive water transport mechanism is analysed in detail.
Die Aufklärung spezifischer Fragestellungen zur Funktionalität von PEM(polymer electrolyte membrane)- und DMFC(Direct Methanol)-Brennstoffzellen bedarf der 3D-Abbildung der spezifischen Komponenten mit unterschiedlichen Strahlungsarten: des Wassergehalts in den Flow Fields mit Neutronen, der Katalysator-Alterung in der MEA (membrane electrode assembly) mit Synchrotronstrahlung und der freien (reaktiven) Katalysator-Oberfläche von Nano-Partikeln mit TEM-Elektronen-Tomografie. Diese Messungen im Bereich der mm- bis nm-Skala unterliegen dabei erheblichen Restriktionen: einer ortsabhängigen Verschmierung der Neutronenradiogramme, Manipulatorinstabilitäten der Synchrotronmessungen sowie einer Kombination von Limited-View-Datensätzen, wenigen Projektionswinkeln und teilweiser Nichtdurchstrahlbarkeit in der Elektronen-CT. Die Vorteile eines fortentwickelten Directt-Algorithmus für die Bewältigung dieser Randbedingungen gegenüber gefilterten Rückprojektionen werden aufgezeigt.
A new high-resolution detector setup for neutron imaging has been developed based on infinity-corrected optics with high light collection, combined with customized mounting hardware. The system can easily be installed, handled and fitted to any existing facility, avoiding the necessity of complex optical systems or further improved electronics (CCD). This is the first time optical magnification higher than 1:1 has been used with scintillator-based neutron detectors, as well as the first implementation of infinity corrected optics for neutron imaging, achieving the smallest yet reported effective pixel size of 3.375 µm. A novel transparent crystal scintillator (GGG crystal) has been implemented with neutrons for the first time to overcome limitations of traditional powder scintillators (Li6/ZnS, Gadox). The standardized procedure for resolution measurements with the Modulation Transfer Function (MTF) is summarized to facilitate comparison between instruments and facilities. Using this new detector setup, a resolution of 14.8 µm with a field of view of 6 mm × 6 mm has been achieved while maintaining reasonable count times. These advances open a wide range of new possible research applications and allow the potential for additional future developments.
While X-ray based darkfield imaging with grating interferometers is already widely used, darkfield imaging with neutrons has still a relatively small user community focused mostly on magnetic materials. Here, we demonstrate the application of neutron darkfield imaging byTalbot-Lau type grating interferometry to fiber reinforced plastics. Common carbon and glass fiber composites have been investigated including characteristic damage structures. The darkfield images show a strong signal response caused by fiber delamination, suitable fiber direction, particles, pores and cracks. The basic principles of neutron darkfield imaging applied to fiber composites are highlighted.
A systematic, nature-inspired chemical engineering approach is employed to solve the issue of flooding in electrochemical devices. The mechanism of passive water transport utilized by lizards living in arid environments is leveraged to design flow-fields with a microchannel structure on their surface, through which capillary pressure rapidly removes the water generated in the electrochemical device. This water management strategy is implemented in proton exchange membrane fuel cells (PEMFCs) with a lunginspired flow-field, which ensures uniform distribution of reactants across the catalyst layer. Jointly, this nature-inspired approach results in flood-free, stable operation at 100% RH and a B60% increase in current (B1.9 A cm-2) and peak power density (B650 mW cm−2) compared to current PEMFCs with a flood-prone, serpentine flow-field (B0.8 A cm-2 and 280 mW cm-2, respectively). This significant advance allows for PEMFC operation at fully humidified conditions.
The potentials of incoherent X-ray scattering (Compton) computed tomography (CT) are investigated. The imaging of materials of very different atomic number or density at once is generally a perpetual challenge for X-ray tomography or radiography. In a basic laboratory set-up for simultaneous perpendicular Compton scattering and direct beam attenuation tomography are conducted by single channel photon counting line scans. This results in asymmetric distortions of the projection profiles of the scattering CT data set. In a first approach, corrections of Compton scattering data by taking advantage of rotational symmetry yield tomograms without major geometric artefacts. A cylindrical sample composed of PE, PA, PVC, glass and wood demonstrates similar Compton contrast for all the substances, while the conventional absorption tomogram only reveals the two high order materials. Comparison to neutron tomography
reveals astonishing similarities except for the glass component (without hydrogen). Therefore, Compton CT offers the potential to replace neutron tomography, which requires much more efforts.
CONRAD-2 is an imaging instrument using low-energy (cold) neutrons. The instrument is installed at the end of a curved neutron guide which avoids the direct line of sight towards the reactor core. This ensures a very low background of high-energy neutrons and. photons at the sample position. The cold neutron beam provides a wavelength range which is suitable for phase-and diffraction-contrast imaging such as grating interferometry and Bragg edge mapping. The instrument is well suited for high resolution imaging due to the high efficiency of the very thin scintillators that can be used for the detection of cold neutrons. An instrument upgrade was performed recently as a part of an upgrade program for the cold neutron instrumentation at HZB. The parameters of the instrument as well as some research highlights will be presented.
X-ray compton tomography
(2014)
The potentials of incoherent X-ray Scattering (Compton) tomography are investigated. Imaging materials of very different density or atomic number at once is a perpetual challenge for X-ray tomography or radiography, in general. In a basic laboratory set-up for simultaneous perpendicular Compton Scattering and direct beam attenuation tomographic scans are conducted by single channel photon counting. This results in asymmetric distortions of the projection profiles of the scattering CT-data set. ln a first approach corrections of Compton scattering data by taking advantage of rotational symmetry yield tomograms without major geometric artefacts.
A cylindrical sample composed of PE, PA, PVC, glass and wood demonstrates similar Compton contrast for all the substances, while the conventional absorption tomogram only reveals the two high order materials.
Compärison to neutron tomography reveals astonishing similarities except for the glass component (without hydrogen). Therefore, Compton CT bears the potential to replace neutron tomography, which requires much more efforts.
We investigated the hydrogen distribution spatially and temporally in technical iron at room temperature. Samples were charged electrochemically and subsequently analysed by means of neutron radiography and tomography. The radiographic images allowed for a time-resolved analysis of hydrogen fluxes. The three-dimensional distribution of hydrogen measured by neutron tomography delivered valuable information for the damage analysis of hydrogen-induced cracks. For the first time hydrogen concentration gradients inside the material could be detect directly together with the cracks. The neutron radiography and tomography results were gained at the Research Reactor BER II of the HZB in Berlin.
We investigated hydrogen embrittlement and blistering in electrochemically hydrogen-charged technical iron samples at room temperature. Hydrogen-stimulated cracks and blisters and the corresponding hydrogen distributions were observed by neutron tomography. Cold neutrons were provided by the research reactor BER II to picture the sample with a spatial resolution in the reconstructed three-dimensional model of ~25 µm. We made the unique observation that cracks were filled with molecular hydrogen and that cracks were surrounded by a 50 µm wide zone with a high hydrogen concentration. The zone contains up to ten times more hydrogen than the bulk material. The hydrogen enriched zone can be ascribed to a region of increased local defect density. Hydrogen also accumulated at the sample surface having the highest concentration at blistered areas. The surfaces of the brittle fractured cracks showed micropores visualized by scanning electron microscopy. The micropores were located at grain boundaries and were surrounded by stress fields detected by electron backscattered diffraction. The cracks clearly originated from the micropores.
Magnetic domains have been the subject of much scientific investigation since their theoretical existence was first postulated by P.-E. Weiss over a century ago. Up to now, the three-dimensional (3D) domain structure of bulk magnets has never been observed owing to the lack of appropriate experimental methods. Domain analysis in bulk matter thus remains one of the most challenging tasks in research on magnetic materials. All current domain observation methods are limited to studying surface domains or thin magnetic films. As the properties of magnetic materials are strongly affected by their domain structure, the development of a technique capable of investigating the shape, size and distribution of individual domains in three dimensions is of great importance. Here, we show that the novel technique of Talbot-Lau neutron tomography with inverted geometry enables direct imaging of the 3D network of magnetic domains within the bulk of FeSi crystals.
CT (computed tomography) reconstructions of fuel cell components of a yet unrivaled spatial resolution and quality are presented. This is achieved by application of the novel DIRECTT (Direct Iterative Reconstruction of Computed Tomography Trajectories) algorithm. We focus on two different key issues which essentially rule the fuel cell's durability on different length scales and physical interactions. On the resolution scale of some 100 µm agglomerations of condensed water in flow-field channels are detected by means of quasi-in situ neutron CT (after operation). Five orders of magnitude below nanometer sized Ru catalyst particles on carbon black support are visualized by electron tomography. Both types of experiments are especially adapted to the type of material involved but they are accompanied by severe deviations from ideal CT measuring conditions, as well. In order to overcome the tremendous reconstruction artifacts of standard algorithms, we employ DIRECTT which is described in detail. Comparisons of DIRECTT reconstructions to the conventional filtered back projection, prove the significant improvements in both experimental methods.
Als Alternative zur Neutronentomographie wird das Potenzial der Computertomographie (CT) mit inkohärenter Röntgen-Streustrahlung (Compton-Streuung) untersucht. Die gleichzeitige Abbildung von Materialien sehr unterschiedlicher Dichten (Ordnungszahlen) ist eine wiederkehrende Herausforderung für die Radiologie und die Computertomographie mit Röntgenstrahlung. Die Messungen ergeben asymmetrische Projektionsprofile für Sinogramme der Streuintensität. Am Beispiel verschiedener Polymere (Polyethylen, Polyamid, PVC), Glas und Holz wird in den Tomogrammen ein hochaufgelöster 'Comptonkontrast' vergleichbarer Dynamik erreicht, während der simultan gemessene 'Absorptionskontrast' ausschließlich die starken Absorber (Glas und PVC) zeigt. Der Vergleich mit ähnlich auflösender Neutronentomographie zeigt ähnliche Kontraste und eröffnet mithin die Möglichkeit, diese künftig durch Compton-Tomographie im Labormaßstab zu ersetzen.