The qualitative and quantitative investigation of historical iron-gall inks using micro-XRF spectrometry is a suitable method for analyzing composition fingerprints of different ink types. The quantitative analysis is based on a model that takes into account the inhomogeneity and the layer structure of archaeometric samples. Starting from these composition fingerprints, it is possible to characterize distinguishable inks of one artist to classify different chronological ink types and, further, to date unknown fragments that have not so far been integrated into the lifework of an artist. The first qualitative and quantitative investigations of the manuscript Faust I and II and of the music composition The Magic Flute demonstrate impressively the identification of J. W. v. Goethe's and W. A. Mozart's artistic work with modern scientific methods. Further investigations on A. v. Arnim's manuscript Studien zu Naturwissenschaften provide evidence that the diversity of various degradation mechanisms of iron-gall inks could be mainly caused by different inorganic compositions.
3D micro X-ray fluorescence spectroscopy - combining elemental analysis with chemical speciation
(2004)
Nowadays, micro-x-ray fluorescence analysis has become an established tool for the non-destructive investigation of art objects. However, as these types of sample often forms complex and inhomogeneous layer systems, the quantitative evaluation of the measurements is far from a standard routine. In this paper a fingerprint model is described, which we developed to discriminate between different iron-gall inks of historical manuscripts or compositions. Fundamental parameter methods are used to take self-attenuation, interference from the paper background and diffusion of the ink into the paper into account. The capability of the method to contribute to the solution of archaeometric problems is exemplified by the investigation of an ancient composition. Finally, the restrictions of the model and possible improvements are discussed. Copyright © 2004 John Wiley & Sons, Ltd.
Model for inhomogeneous ink paper layer systems measured with micro X-ray fluorescence analysis
(2002)
Naturwissenschaftliche Informationen, insbesondere die chemische Zusammensetzung der Objekte, können Hinweise auf die Hintergründe der Objektherstellung liefern, die der alleinigen kunsthistorischen Begutachtung verborgen blieben. Es können nicht nur Fragen nach dem Prozess, Zeitpunkt und Ort der Herstellung beantwortet werden. Die chemische Analyse gibt auch Hinweise auf Ereignisse und Veränderungen, die erst nach der Fertigstellung des Objektes erfolgten. So werden Alterungsphänomene oder historische Überarbeitungen und Restaurierungen aufgedeckt, aber auch Konservierungsstrategien zur Erhaltung der Kunstwerke unterstützt. Durch den technologischen Fortschritt im Bereich der röntgenanalytischen Methoden, die berührungsfrei, ohne Probennahme und ohne Schädigung für das Untersuchungsobjekt arbeiten, erschließen sich dem Analytiker erstmalig Möglichkeiten, auch sehr wertvolle und fragile Objekte zerstörungsfrei zu untersuchen.
Nowadays, micro-x-ray fluorescence analysis has become an established tool for the non-destructive investigation of art objects. However, as these types of sample often forms complex and inhomogeneous layer systems, the quantitative evaluation of the measurements is far from a standard routine. In this paper a fingerprint model is described, which we developed to discriminate between different iron-gall inks of historical manuscripts or compositions. Fundamental parameter methods are used to take self-attenuation, interference from the paper background and diffusion of the ink into the paper into account. The capability of the method to contribute to the solution of archaeometric problems is exemplified by the investigation of an ancient composition. Finally, the restrictions of the model and possible improvements are discussed. Copyright © 2004 John Wiley & Sons, Ltd.
We studied the oxidation and migration processes of inorganic compounds in iron gall inks with a combination of micro X-ray fluorescence analysis (micro-XRF) and micro X-ray absorption near edge structure spectroscopy (micro-XANES). With elemental mapping by micro-XRF, the correlation of the minor elements in the ink to the major element Fe was investigated. Along concentration profiles of Fe, micro-XANES measurements were carried out in order to determine the oxidation state and the local environment. With the help of model inks, we could show that Cu is a further important element in the paper degradation process due to iron gall ink corrosion.
A combination of 3D micro X-ray fluorescence spectroscopy (3D micro-XRF) and micro-XRF was utilized for the investigation of a small collection of highly heterogeneous, partly degraded Dead Sea Scroll parchment samples from known excavation sites. The quantitative combination of the two techniques proves to be suitable for the identification of reliable marker elements which may be used for classification and provenance studies. With 3D micro-XRF, the three-dimensional nature, i.e. the depth-resolved elemental composition as well as density variations, of the samples was investigated and bromine could be identified as a suitable marker element. It is shown through a comparison of quantitative and semiquantitative values for the bromine content derived using both techniques that, for elements which are homogeneously distributed in the sample matrix, quantification with micro-XRF using a one-layer model is feasible. Thus, the possibility for routine provenance studies using portable micro-XRF instrumentation on a vast amount of samples, even on site, is obtained through this work.
In this study, we address the question of the
provenance and origin of the Dead Sea Scrolls manuscripts.
A characteristic low ratio of chlorine to bromine, corresponding
to that of the Dead Sea water, may serve as an indicator for
local production. For this aim we developed a non-destructive
procedure to determine the Cl/Br ratio in the parchment of
these manuscripts. Micro-X-ray fluorescence (µ-XRF) measurements
of a large number of parchment and leather
fragments from the Dead Sea Scrolls were analyzed with a
routine we developed based on fundamental parameter
quantification. This routine takes into account the absorption
of the collagen matrix and the influence of the different sample
thicknesses. To calculate the representative Cl/Br ratio for each
fragment, we investigated the lateral homogeneity and
determined the total mass deposition using the intensity of
the inelastically scattered, characteristic tube radiation. The
distribution of the Cl/Br ratios thus obtained from the µ-XRF
measurements make it possible to distinguish fragments
whose origin lies within the Dead Sea region from those
produced in other locations.
3D Micro X-ray fluorescence analysis was used for the investigation of reverse-glass paintings. The material-specific combination used in reverse-glass paintings leads to damage phenomena reinforced by glass corrosion. To elucidate the mechanism of corrosion processes taking place in the glass object depth profiles of mobile elements are of interest. In order to obtain elemental depth profiles of such kind of fragile objects the method of choice should be non-destructive. Our first results demonstrate the usefulness of the 3D Micro-XRF measurements for this kind of investigations. The assumption that certain binding media may initiate corrosion processes beginning at the interface glass/binding material could be confirmed.
The Dead Sea Scrolls belong to the most important cultural assets of mankind. Their long term preservation and study is a challenge that demands an interdisciplinary approach. As early as the 1950s natural scientists assisted the scholars in studying the scrolls. It was at this time that the first extensive study of the scroll material took place. It was found that most fragments were written not on leather but on parchment. In addition, a method for determining the age of the parchment was developed which is still of value today. In the 1990s the AMS-C14 method confirmed the palaeographic determination of the age of the manuscripts. The use of carbon ink throughout the scrolls is also consistent with the known scribal practices of that time. There are, however, manuscripts, and among them the famous Genesis Apocryphon Scroll, which exhibit ink corrosion, normally associated with iron-gall inks.
Today, 60 years after their discovery, a community of scientists from the Jewish National and University Library (JNUL), the Technical University of Berlin (TU Berlin), the Federal Institute for Materials Research and Testing (BAM) and Fritz-Haber-Institute of the MPG (FHI) set out to scientifically investigate the finds of Qumran using the most modern methods. The results of the study will be used to determine the provenance of the texts as well as to contribute to their long-term preservation. A considerable part of the non-destructive investigation is taking place in the Berlin State Library and at the Berliner Elektronenspeicherring-Gesellschaft für Synchrotronstrahlung , BESSY II.
Preliminary investigations, performed at the BAM on some fragments, were used to evaluate the extent to which X-ray analytical methods can provide information regarding the geographical origin of the fragments and match the individual pieces. The interpretation of the measurement results is made more difficult by age and storage of the objects. It is believed that ageing processes as well as conservation methods have altered the samples in addition to the changes caused by environmental influences.
In collaboration with the TU Berlin, the samples from the parchments found in the caves near Qumran were tested by means of three-dimensional synchrotron based X-ray fluorescence analysis (3D-SyXRF). The aim of this non-destructive investigation was the identification of the inorganic material used in the manufacture of the parchments.
The XRF experiments are supported by the non-destructive analysis by means of synchrotron based infrared spectroscopy (SyFTIR) in collaboration with BESSY II as well as optical and electron microscopy in collaboration with Fritz-Haber-Institute (FHI).
Naturwissenschaftler arbeiten mit Archäologen, Kunsthistorikern und Restauratoren zusammen, um Materialinformationen über Kunstwerke mit den Erkenntnissen aus Altertumsforschung, Kunstgeschichte und Denkmalpflege zu verbinden. Röntgenfluoreszenz und Röntgenemission sind die Methoden der Wahl, wenn wertvolle und fragile Objekte zerstörungsfrei zu untersuchen sind.
In this work, the applicability of a new 3D micro X-ray fluorescence (3D Micro-XRF) laboratory spectrometer for the investigation of historical glass objects is demonstrated. The non-destructiveness of the technique and the possibility to measure three-dimensionally resolved fluorescence renders this technique into a suitable tool for the analysis of cultural heritage objects. Although absorption and resolution effects complicate qualitative analysis of the data, layered structures can be distinguished from homogeneous samples without the need for full quantification. Different manufacturing techniques were studied in this work with the help of hand-made reference samples. With the gained knowledge it could be shown for the investigated historical glass object, that black enamel as a stained glass contour colour was used in a cold painting. The object was not fired after the application of the black enamel, but instead the adhesion of the paint was solely provided through organic binding agents and the backing with metal foils. Thus, for the manufacturing of the object, a mixture of cold painting technique with a stained glass color was used. Quantitative measurements with a 3D Micro-XRF setup at the Berlin synchrotron BESSY II confirm the assumptions drawn on the basis of the qualitative investigation with the 3D Micro-XRF spectrometer with X-ray tube excitation.
A new approach for chemical speciation in stratified systems using 3D Micro-XAFS spectroscopy is developed by combining 3D Micro X-ray Fluorescence Spectroscopy (3D Micro-XRF) and conventional X-ray Absorption Fine Structure Spectroscopy (XAFS). A prominent field of application is stratified materials within which depth-resolved chemical speciation is required. Measurements are collected in fluorescence mode which in general lead to distorted spectra due to absorption effects. Developing a reliable reconstruction algorithm for obtaining undistorted spectra for superficial and in-depth layers is proposed and validated. The developed algorithm calculates the attenuation coefficients of the analyte for the successive layers facilitating a new spectroscopic tool for three-dimensionally resolved nondestructive chemical speciation.
Polycapillary halflenses are widely used to focus X-ray radiation onto a small spot. Additionally they can reduce the field of view of a semiconductor detector when placed in front of one. In 3D micro X-ray fluorescence spectroscopy (3D Micro-XRF) with synchrotron radiation, two polycapillary halflenses are used in a confocal geometry. Up until now, characterization measurements in the focal plane have only been performed in the case of the lens focusing parallel radiation. Assumptions have been made, that in the other case, when isotropic radiation from a spot source is transported to a detector, the acceptance distribution in the focal plane is also Gaussian. We performed measurements with an electron beam as well as a proton beam which confirm this assumption. In addition, a comparison between measurements in collecting and focusing mode show differences in spot size and transmission. These differences exemplify the fact that there is not one global spot size or transmission function of a polycapillary halflens. Illumination and divergence effects can alter both characteristic lens parameters.
A new fundamental parameter based calibration procedure for micro X-ray fluorescence spectrometers
(2011)
Fundamental parameter based quantification of X-ray fluorescence (XRF) measurement data requires an accurate knowledge of the spectrometer parameters, including the spectral distribution of the excitation radiation. In case of micro-XRF where a polycapillary optic is utilized in the excitation channel this distribution is changed due to the transmission properties of the lens. A new calibration procedure, based on fluorescence data of thin standard samples, was developed to determine the excitation spectrum, i.e., the product of the X-ray tube spectrum and the transmission of the used X-ray optic of a micro-XRF setup. The calibration result was validated by the quantitative analyses of certified multi-element reference standards and shows uncertainties in the order of 2% for main components, 10% for minor elements and 25% for trace elements. The influence of secondary order effects like Coster–Kronig transitions and cascade effects is analyzed and the accuracy of fundamental parameters in common databases is discussed.
High Speed, High Resolution imaging spectrometers based on pnCCDs for XRF and XRD applications
(2016)
For many years pnCCDs have been well known as X-ray detectors for spectroscopic imaging in many fields of science: X-Ray Fluorescence analysis (XRF), X-ray Diffraction (XRD) with light sources in large accelerator facilities as well as with laboratory light sources or with X-rays from celestial sources in X-ray astronomy. A brief introduction in GEXRF (Grazing Emission XRF) measurements with a laboratory laser produced plasma source will be given, PIXE (Particle Induced X-ray Emission) measurements and D2XRF (Double Dispersive X-Ray Fluorescence) and Slicing experiments with pnCCDs coupled to polycapillary optics performed at the BESSY synchrotron will be shown. Energy-dispersive Laue diffraction with ultra-hard X-rays for the analysis of defects in metals will conclude the overview of spectroscopic X-ray imaging measurements in the field of structure and dynamics of matter.
A sealable ultrathin window sample cell for the study of liquids by means of soft X-ray spectroscopy
(2017)
A new sample cell concept for the analysis of liquids or solid-liquid interfaces using soft X-ray spectroscopy is presented, which enables the complete sealing of the cell as well as the Transport into vacuum via, for example, a load-lock system. The cell uses pressure monitoring and active as well as passive pressure regulation systems, thereby facilitating the full control over the pressure during filling, sealing, evacuation, and measurement. The cell design and sample preparation as well as the crucial sealing procedure are explained in detail. As a first proof-of-principle experiment, successful nitrogen K-edge fluorescence yield near-edge X-ray absorption fine structure experiments of a biomolecular solution are presented. For this purpose, it is shown that the careful evaluation of all involved parameters, such as window type or photon flux, is desirable for optimizing the experimental result.