Filtern
Erscheinungsjahr
Dokumenttyp
Sprache
- Englisch (35) (entfernen)
Schlagworte
- Column tests (5)
- Leaching (5)
- Column test (4)
- Composite liner (4)
- Contaminated soil (4)
- PAH (4)
- Batch test (3)
- Batch tests (3)
- Leaching procedures (3)
- Liquid-liquid extraction (3)
Artificial surfaces for outdoor sporting grounds may pose environmental and health hazards that are difficult to assess due to their complex chemical composition. Ecotoxicity tests can indicate general hazardous impacts. We conducted growth inhibition (Pseudokirchneriella subcapitata) and acute toxicity tests (Daphnia magna) with leachates obtained from batch tests of granular infill material and column tests of complete sporting ground assemblies. Ethylene propylene diene monomer rubber (EPDM) leachate showed the highest effect on Daphnia magna (EC50 < 0.4% leachate) and the leachate of scrap tires made of styrene butadiene rubber (SBR) had the highest effect on P. subcapitata (EC10 = 4.2% leachate; EC50 = 15.6% leachate). We found no correlations between ecotoxicity potential of leachates and zinc and PAH concentrations. Leachates obtained from column tests revealed lower ecotoxicological potential. Leachates of column tests of complete assemblies may be used for a reliable risk assessment of artificial sporting grounds.
Scrap tyres are widely reused in the form of granules as infill materials or component of sub-base layers in construction of sporting grounds such as synthetic turf areas and athletic track surfaces. The recycled rubber may contain organic and inorganic pollutants due to the presence of vulcanisation catalysts, stabilisers and other additives which can be released into soil and groundwater in the case of outdoor sports facilities. In order to evaluate the amount of potentially mobile pollutants, leaching tests can be employed. This study aimed particularly at the investigation of the feasibility of column tests using complete synthetic surface flooring or turf system assemblies. The release of zinc and polycyclic aromatic hydrocarbons (PAH) leached from components of sports surfaces containing recycled rubber granules was considered. Additionally, batch tests on coated and uncoated styrene butadiene rubber (SBR) granules aged by artificial weathering were performed to indicate its possible influence on the leaching behaviour of zinc and PAH. The chosen approach of column tests simulating typical complete synthetic sports surface installations has been proven to be feasible and robust. The time-dependent leaching behaviour and interactions between single components can be evaluated by column tests. Zinc was the most relevant contaminant in the eluates and its leachability was enhanced after accelerated ageing by artificial weathering. Leachable PAH were found in relatively low but well detectable amounts which increase by ageing as well.
Synthetic athletic tracks and turf areas for outdoor sporting grounds may release contaminants due to the chemical composition of some components. A primary example is that of zinc from reused scrap tires (main constituent, styrene butadiene rubber, SBR), which might be harmful to the environment. Thus, methods for the risk assessment of those materials are required. Laboratory leaching methods like batch and column tests are widely used to examine the soil–groundwater pathway. We tested several components for artificial sporting grounds with batch tests at a liquid to solid (LS) ratio of 2 L/kg and column tests with an LS up to 26.5 L/kg. We found a higher zinc release in the batch test eluates for all granules, ranging from 15% higher to 687% higher versus data from column tests for SBR granules. Accompanying parameters, especially the very high turbidity of one ethylene propylene diene monomer rubber (EPDM) or thermoplastic elastomer (TPE) eluates, reflect the stronger mechanical stress of batch testing. This indicates that batch test procedures might not be suitable for the risk assessment of synthetic sporting ground components. Column tests, on the other hand, represent field conditions more closely and allow for determination of time-dependent contaminants release.
The risk assessment of total petrol hydrocarbons (TPH) and polycyclic aromatic hydrocarbons (PAH), two of the most frequent soil and water contaminants, has to include their exposure pathways, especially the soil groundwater pathway. Threshold values have to be aquired for the amendment to the German Federal Soil Protection Contaminated Sites Ordinance. For this purpose, a batch experiment with a liquid to solid ratio (L/S) of 2 L/kg was developed. Aim of this work was to verify the robustness of this leaching procedure for TPH and PAH in different soil types against varying test conditions. Also, stir bar sorptive extraction (SBSE) was tested as alternative sample preparation of eluates for PAH analysis.
Leaching tests are fundamental tools for the assessment of long-term impact of contaminated waste materials on the soil-groundwater pathway. Experiments were carried out in the framework of standardization and validation of column percolation and batch test procedures, in particular concerning the stipulation of the experimental setup. The colloid release of column and batch experiments was compared and the influence of different column filling heights (12.5–50 cm) on the release of polycyclic aromatic hydrocarbons (PAH) from soil was studied, as well as the effect of varying contact times (2.5–16 h) on the release of chromium from construction and demolition (C&D) waste and municipal solid waste incineration (MSWI) bottom ash. The results indicate that filtration of the eluate, which is required for batch tests, does not always allow the simulation of the actual colloid amount in soil pore water. Medium column heights four times the inner diameter of the column seemed to provide reasonable equilibrium adjustment conditions and avoid major biodegradation. The release of chromium was only marginally affected by the contact time, varied between 0.115 and 0.150 mg/kg for demolition waste eluate at a liquid-to-solid ratio of approximately 5 L/kg.
Monitoring of PAH in aqueous samples - a comparison of different sample preparation techniques
(2011)
Stir bar sorptive extraction (SBSE) is an equilibrium extraction method used amongst others for the analysis of polycyclic aromatic hydrocarbons (PAH) in aqueous samples. We compared SBSE to liquid–liquid extraction (LLE) for aqueous eluates obtained from batch and column tests of PAH contaminated soils to check whether SBSE might be considered as an alternative sample preparation method. We used soils with different particle size distribution, organic matter content, and resulting eluate turbidity to test the sample preparation methods on eluates with matrices of varying complexity. Furthermore, we studied the influence of diluted organic matter (DOM) on the PAH sorption process to the polymer coating of the stir bar during SBSE. In the majority of cases, we found higher PAH concentrations (up to 288%) with SBSE than with LLE. The turbidity correlates with the difference in PAH results, i.e. the greater the turbidity in the eluate, the more PAH we found with SBSE compared to LLE. We observed no similar trend regarding the amount of total organic carbon (TOC). The presence of DOM in the eluate seems to hamper the SBSE slightly, the PAH recovery varied between 82 and 104%.
When reusing or disposing of contaminated granular waste materials there is a need to evaluate how the contaminants will interact on the pathway soil-groundwater and the effect this interaction will have on the surrounding environment. While column testing can provide a closer approximation to field percolation conditions than batch testing, there is still a need to develop column testing procedures that consider the requirements of practical testing time frames. This study evaluates the effect of different column contact times (2.5, 5, and 16 h) on the release of inorganic constituents from bottom ash and demolition waste, two commonly reused granular materials. Leaching data for representative constituents of concern, such as copper, chromium, sulfate and chloride, as well as pH and electrical conductivity was compared for all different contact times studied.
Results for the materials investigated in this study showed that variations in contact time have no significant effect on the release of the selected constituents and leaching parameters at low liquid to solid ratios. However, after a liquid to solid ratio of 1 L/kg, the effect is more noticeable, and higher contact times show lower pH values as well as a reduction in the release of constituents of concern from bottom ash. In the case of demolition waste, the variation of contact time did not have a strong effect on the leaching behavior.
Leaching experiments on the release of heavy metals and PAH from C&D waste and MSWI bottom ash
(2010)
Leaching tests are fundamental tools for the assessment of long-term impact of
contaminated waste materials on the soil-groundwater pathway. Waste materials should be
tested under conditions equal to their actual application in re-use scenarios to achieve reliable
results. Since the standards for leaching procedures available on international level so far are
either not validated or considered inadequate in respect to coarse grained materials, new
standards had to be developed. Therefore column percolation and batch test procedures have
been standardized and validated to enable their introduction to new German regulations
concerning waste management. Practical aspects of the test procedures as well as the
boundary conditions compared to the already existing standards will be described. Examples
including round robin test results will be given to justify the selection of the new
specifications.
Results of German ring tests on the vaildation of leaching standards for source term determination
(2009)
Laboratory leaching tests may be used for source term determination as a basis for risk assessment for soilgroundwater pathways on contaminated sites. In order to evaluate different leaching procedures, batch extraction tests and percolation tests were performed using three reference materials produced from contaminated soil, demolition waste and municipal solid waste incinerator bottom ash. Emphasis was placed on the investigation of the leachability of the heavy metals copper and chromium, polycyclic aromatic hydrocarbons (PAHs) and the anions chloride and sulfate. Significant discrepancies between column experiments and batch/extraction tests were found for the release of PAHs and to a lesser extent for the heavy metals Cu and Cr. Additionally interlaboratory comparisons were conducted based on different leaching tests with the reference materials and evaluated using the criteria of comparability and reproducibility. The best reproducibility was achieved for all investigated substances in column tests. The reproducibility of batch tests was acceptable except for PAHs. The results from the experimental work will help establish standardized and feasible laboratory procedures as fundamental for substance specific risk assessment of contaminated sites.
This article presents a snapshot of key issues regarding characterization of granular waste materials with respect to their reuse as alternative construction materials, and the factors that need to be considered in their reutilization in order to comply with soil and groundwater protection regulations.
Laboratory leaching tests may be used for source term determination as a basis for risk assessment for soilgroundwater pathway (leachate forecast) on contaminated sites in Germany. Interlaboratory comparisons on the evaluation of the reproducibility of column percolation tests were conducted within the framework of an integrated R + D program using three waste reference materials.
The interlaboratory comparisons of column percolation tests showed good reproducibility of the results for inorganic and organic parameters as well as for the accompanying parameters. This is due to the stipulations concerning the time of contact between leachant and sample material as well as the sample placement in the columns. Different column dimensions used by the participants of the interlaboratory comparisons did not have any substantial influence on the column test results.
Composite liners (a geomembrane in intimate contact with a mineral liner) are frequently used to line landfills and contaminated sites. It is therefore very important to characterise the behaviour of these systems even under extreme conditions.
An investigation was undertaken to determine the influence of a mixture of concentrated organic contaminants on composite liner materials taken from test cells that had been dismantled after a 12-year permeation test.
The organic hydrocarbons had permeated the HDPE-geomembrane and had then migrated or had been adsorbed within the mineral liners, depending on their properties. The obtained concentration profiles of the contaminant mixture components indicate that the various mineral layer materials have selective retardation abilities which correspond to the different parameters of the organic compounds as well as of the mineral layer.
In addition, contaminant transport in the composite liners tested was modelled and the results of the model analysis compared with measurement data. An example (acetone) illustrates the calculated spatial and temporal contaminant concentration.
The composite liners investigated exhibit a very good sealing capacity against the concentrated organic contaminants used.
The fabric of mineral liner materials that had been exposed to organic compounds over a 12-year period was investigated as part of a wider research project. Macromorphological and micromorphological changes in the fabric were identified using computed tomography and polarisation microscopy.
Special care was taken to ensure artefact free sampling and sample preparation, in particular, the drying method used, has a substantial influence on the quality of the thin sections.
Fabric changes due to contaminant permeation over several years are, by and large, relatively small and their intensity is material specific. Silty clay CML1, in particular, contains a somewhat greater number of fissures and voids in comparison with the original material. The superposition of various processes in both test procedures and sample preparation may lead to fabric changes which can impede interpretation of the results.