Filtern
Erscheinungsjahr
Dokumenttyp
- Vortrag (53)
- Beitrag zu einem Tagungsband (51)
- Zeitschriftenartikel (45)
- Beitrag zu einem Sammelband (32)
- Forschungsbericht (25)
- Sonstiges (2)
- Monografie (1)
- Posterpräsentation (1)
Sprache
- Deutsch (106)
- Englisch (103)
- Mehrsprachig (1)
Schlagworte
- VOC (44)
- Bauprodukte (27)
- Emissionen (25)
- Emission test chamber (22)
- SVOC (20)
- Geruch (19)
- Emission (10)
- GC/MS (8)
- VVOC (7)
- AgBB-Schema (6)
- Blauer Engel (6)
- Emissions (6)
- Odour (6)
- Radon (6)
- Radon exhalation (6)
- Thermal desorption (6)
- VOC emission (6)
- AgBB (5)
- Building material (5)
- Construction product (5)
- Construction products (5)
- Dust (5)
- Emissionsmesskammern (5)
- Interlaboratory study (5)
- Kammermessungen (5)
- Luft (5)
- OSB (5)
- Ozone (5)
- AbBB-Schema (4)
- AgBB-Scheme (4)
- Emissionsmessungen (4)
- Flame retardants (4)
- Formaldehyde (4)
- Luftschadstoffe (4)
- Perceived intensity (4)
- Round robin test (4)
- Volatile organic compounds (4)
- BEMMA (3)
- Bewertung (3)
- Bewertung Emissionen (3)
- Building materials (3)
- Building product (3)
- Building products (3)
- Chamber test (3)
- Copiers (3)
- Drucker (3)
- Emissionsmesskammer (3)
- ISO 16000-6 (3)
- Indoor air quality (3)
- Innenraum (3)
- Laborvergleich (3)
- Laserdrucker (3)
- Material emission (3)
- Odour evaluation (3)
- Odour measurement (3)
- Organophosphates (3)
- Ozon (3)
- Perceived air quality (3)
- Polybrominated flame retardants (3)
- Polymer (3)
- Printers (3)
- Radon measurement (3)
- Reference material (3)
- Standardisation (3)
- Staub (3)
- Acceptability (2)
- Aerosol (2)
- Aldehyde (2)
- Bauprodukt (2)
- Biocide (2)
- Biocides (2)
- Blue Angel (2)
- Bodenbeläge (2)
- Brominated flame retardants (2)
- Bürogeräte (2)
- Chamber study (2)
- Cultural heritage (2)
- Dämmstoffe (2)
- Emission measurements (2)
- Emission testing (2)
- Emission tests (2)
- Emissionsmesszelle (2)
- Emissionsprüfkammer (2)
- Empfundene Intensität (2)
- External quality management system (2)
- Formaldehyd (2)
- GC-ODP (2)
- Gas mixing device (2)
- Geruchsmessungen (2)
- Hardcopy devices (2)
- Hedonic tone (2)
- Hedonik (2)
- Indoor air (2)
- Interlaboratory comparison (2)
- Kammerverfahren (2)
- Kopierer (2)
- Kulturguterhaltung (2)
- Odour standard of comparison (2)
- Particle board (2)
- Partikelemissionen (2)
- Pentabromdiphenylether (PentaBDE) (2)
- Perceived odour intensity (2)
- Polybromierte Flammschutzmittel (2)
- Proficiency testing (2)
- Präventive Konservierung (2)
- RAL-UZ 122 (2)
- Richtlinie 2003/11/EG (2)
- Richtlinie 76/769/EWG (2)
- SVOC/POM (2)
- Semi volatile organic compounds (2)
- TVOC (2)
- Tenax thermal desorption (2)
- Test chambers (2)
- Thermodesorption (2)
- Umweltsimulation (2)
- VOC analysis (2)
- VOC-emission (2)
- Wood (2)
- Abklingverhalten (1)
- Acetic acid (1)
- Acrylic and silicone sealant (1)
- Adsorptive wall material (1)
- Aerosols (1)
- AgBB Scheme (1)
- AgBB evaluation scheme (1)
- AgBB scheme (1)
- AgBB-scheme (1)
- Air (1)
- Air exchange rate (1)
- Air sampling (1)
- Alterung (1)
- Antioxidant (1)
- Antioxidantien (1)
- Assessment of emissions from materials for museum equipment (1)
- Assessment procedure (1)
- Ausstellungsvitrinen (1)
- BEMMA display case (1)
- Baumaterialien (1)
- Bauproduktenverordnung (1)
- Bio-based insulation (1)
- Biocidal products (1)
- Biocides directive (1)
- Biozidanalytik (1)
- Bürogerät (1)
- Bürogeräte mit Druckfunktion (1)
- Bürogeräte mit Laserdruckfunktion (1)
- Carbograph 5TD (1)
- Carbopack X (1)
- Carbotrap 300 (1)
- Cell (1)
- Chamber (1)
- Chamber copmparison (1)
- Chamber tests (1)
- Chemische Emissionen (1)
- Computer (1)
- Construction and renovation (1)
- Construction material (1)
- Construction materials (1)
- Construction products directive (1)
- Consumer products (1)
- Coverings (1)
- Cyclosiloxanes (1)
- DIN EN 16516 (1)
- DNPH (1)
- Direct thermal extraction (1)
- Directive (1)
- Directive 2003/11/EC (1)
- Directive 76/769/EEC (1)
- Dynamic gas generation (1)
- EN 16516 (1)
- EN 717-1 (1)
- EN-Standards (1)
- Earthen building materials (1)
- Electronics (1)
- Emission chamber (1)
- Emission chamber test (1)
- Emission chamber testing (1)
- Emission from materials (1)
- Emission rates (1)
- Emission test (1)
- Emission test cells (1)
- Emission test chambers (1)
- Emissionsarme Vitrine (1)
- Emissionsarme Vitrinen (1)
- Emissionsmessung (1)
- Emissionsprüfkammern (1)
- Emissionsprüfung (1)
- Emissionsprüfzelle (1)
- Environmental analyses (1)
- Environmental exposure assessment (1)
- Environmental label (1)
- Environmental sign (1)
- Ethanol (1)
- European standard (1)
- Evaluation (1)
- Evaporation (1)
- FP (1)
- FTIR (1)
- Feine und ultrafeine Partikel (1)
- Floor coverings (1)
- Flooring material (1)
- Flüchtige Emission (1)
- Flüchtige organische Verbindungen (1)
- Foam tiles (1)
- Formic acid (1)
- Fragrance allergens (1)
- Fußbodenbelagskleber (1)
- Gas atmosphere (1)
- Gas chromatography (1)
- Gas mixing system (1)
- Gas sensor (1)
- Geruchsmessung (1)
- Geruchstest (1)
- Gesundheit (1)
- Hard copy devices (1)
- Hardcopy device (1)
- Hardcopygerät (1)
- Health assessment (1)
- Health care (1)
- Hedonic (1)
- Holz (1)
- Holzwerkstoffe (1)
- Hydrocarbon (1)
- Indoor Air: Adsorbent performance (1)
- Inhalation exposure (1)
- Innenraumluft (1)
- Innenraumluftqualität (1)
- Innenraumluftqualtität (1)
- Insulation material (1)
- Inter laboratory study (1)
- Kleber (1)
- Kohlenwasserstoff (1)
- Label (1)
- Labelling (1)
- Labelling systems (1)
- Labelsysteme (1)
- Lacquers (1)
- Laser printer (1)
- Laser printers (1)
- Laserprinters (1)
- Leaching procedure (1)
- Leimholz (1)
- Leiterplatte (1)
- Loading factor (1)
- Low VOC concentrations (1)
- Low gas concentrations (1)
- Material labelling (1)
- Materialien (1)
- Materials (1)
- Matratze (1)
- Measurement method (1)
- Measurement methods (1)
- Messmethoden (1)
- Methanol (1)
- Micro-chamber (1)
- Monitor (1)
- Montageschäume (1)
- Museum (1)
- Möbel (1)
- Natural materials (1)
- Normung (1)
- Octabromdiphenylehter (OctaBDE) (1)
- Octabromdiphenylether (OctaBDE) (1)
- Octabromo Diphenylether (octaBDE) (1)
- Odor (1)
- Odour assessment (1)
- Odour intensity (1)
- Odour labelling (1)
- Olfactory detection port (1)
- Organic acids (1)
- Organophosphorus flame retardants (1)
- Oriented Strand Board (1)
- Oriented strand board (1)
- Oriented strand boards (OSB) (1)
- Paints (1)
- Particle emissions (1)
- Particles (1)
- Particulate Organic Matter (POM) (1)
- Particulate emissions (1)
- Partikel (1)
- Partikelemission (1)
- Pentabromo Diphenylether (pentaBDE) (1)
- Perceived Air Quality (1)
- Perceived air-quality (1)
- Phosphororganische Flammschutzmittel (1)
- Plywood Board (1)
- Pollutant (1)
- Polstermöbel (1)
- Polyurethane foam (1)
- Probenahmebehälter (1)
- Product emission testing (1)
- Product labelling (1)
- Produkte (1)
- Produkttypischer Geruch (1)
- Profiling (1)
- Protection of cultural object (1)
- Prüfkammer (1)
- Prüfmethode (1)
- Prüfverfahren (1)
- RAL UZ (1)
- Radon monitors (1)
- Real room radon concentrations (1)
- Reasonability (1)
- Recovery rate (1)
- Reduktion (1)
- Reference odour (1)
- Repeatability (1)
- Reproducibility (1)
- Ringversuch (1)
- Robustness validation (1)
- Round robin (1)
- Rround robin test (1)
- SDVB-polymer (1)
- Scented toys (1)
- Schadstoff (1)
- Schadstoffe (1)
- Schutz vor Kunst- und Kulturgut (1)
- Schwerflüchtige organische Verbindungen (1)
- Secondary emissions (1)
- Semi Volatile Organic Compounds (SVOC) (1)
- Semi volatile organic compounds (SVOC) (1)
- Semivolatile organic compounds (1)
- Sensor system (1)
- Sensor systems (1)
- Sensorik (1)
- Sensorsystem (1)
- Sensory evaluation (1)
- Sensory tests (1)
- Showcase (1)
- Simulated rain (1)
- Sorption flux (1)
- Standardization (1)
- TXRF-NEXAFS (1)
- Tenax (1)
- Test method (1)
- Test procedure (1)
- Test procedures (1)
- Testing method (1)
- Testing using sensors (1)
- Thermal extraction (1)
- Toner (1)
- UFP (1)
- Ultra fine particle (1)
- Umweltzeichen (1)
- VOC Emissionen (1)
- VOC emission test chamber (1)
- VOC emissions (1)
- VOC gas mixtures (1)
- VOC-Emissionen (1)
- VOCs (1)
- VOCs and SVOCs (1)
- VVOCs (1)
- Vergleichspräzision (1)
- Verlegewerkstoffe (1)
- Verpackungsmaterialien (1)
- Very volatile organic compounds (1)
- Vitrinen (1)
- Volatile emission (1)
- Volatile organic compound (1)
- Volatile organic compound (VOC) (1)
- Water (1)
- Wiederholpräzision (1)
- Wood Products (1)
- Wood preservatives (1)
- Wood-based product (1)
- XRF (1)
- beschichtete Holzwerkstoffe (1)
- sensory evaluation of building materials and rooms (1)
Organisationseinheit der BAM
Paper des Monats
- ja (1)
Eingeladener Vortrag
- nein (53)
The European biocides directive (98/8/EG) demand the control of emissions into the envi-ronment like soil, water and air. In this study a method for measuring the input of biocides into the indoor air from materials should be developed. The emission of two products containing biocides (plastic foil, wool carpet) and six different types of biocide containing formulations applied on wood or ceramic tiles were investigated in 20 or 23 l glass emission chambers. Each chamber test was performed over a period of 100 up to 200 days. SVOC show totally different emission curves in chamber tests compared to volatile organic com-pounds (VOC). They reach their maximum value after some days or weeks. Thus a period of 3 months is sometimes necessary for exact measurements. Area specific emission rates (SERa in µg/m²h) for permethrin (0.006), propiconazole (0.2), dichlofluanid (1.5), tolylfluanid (1.2), octylisothiazolinone (2.5) and for iodpropinylbutyl-carbamat (1.7) were determined.
Entwicklung einer umweltverträglichen Holzklebetechnik durch den Einsatz von Proteinbindemitteln
(2003)
Biocides are used to protect materials that might be damaged by fungal, microbial or insect activity. The aim of this study is to develop a method for the measurement of these organic compounds, which generally have low or moderate vapor pressures. The biocides considered in this study are permethrin, dichlofluanid, tolylfluanid, iodpropinylbutylcarbamat, octylisothiazolinone, tebuconazole and propiconazole. The emission from two commercial products (plastic foil, wool carpet) containing biocides and of seven types of biocidal formulations applied to wood or clay tiles were investigated in 20-l glass emission test chambers. Each chamber test was performed over a period of 100200 days, and one investigation was conducted over several years. Compared to volatile organic compounds, low-volatility compounds show totally different emission curves in chamber tests; maximal emission values may be reached in days or weeks. A period of 3 months is sometimes necessary for the determination of area-specific emission rates (SERa's). The SERa's (?g m-2 h-1) from biocide-containing products were determined for permethrin (0.006), propiconazole (0.3), dichlofluanid (2.0), tolylfluanid (1.0), octylisothiazolinone (2.5) and iodpropinylbutylcarbamat (2). In most cases, the SERa stayed at its maximum value or declined slowly over the test period. Additionally, a chamber test begun in 1994 with a piece of wood treated with a typical mixture of biocides dissolved in a technical solvent was continued. SERa's (?g m-2 h-1) for dichlofluanid (0.20), tebuconazole (0.49) and permethrin (0.08) remained detectable after the period of nearly 9 years during which the sample remained continuously in the chamber. This test proved the very slow decrease of emission of low-volatility compounds like permethrin and tebuconazole.
Innenraumluftschadstoffe
(2002)
Möglichkeiten und Grenzen bei der Bestimmung von SVOC-Emissionen aus Materialien und Produkten
(2002)
The emission levels of high boiling brominated (BFR) and phosphoric (POC) flame retardants (FR) in different materials were examined. For the determination of the emission rate the tests were done in different emission test chambers and cells under standard conditions (23 C, 50% RH and fixed area specific air flow rates). Selected products, e.g. printed circuit boards, were investigated at elevated temperature (e.g. 60 C) to simulate working conditions. Applied analytical techniques for the air samples adsorbed on polyurethane foam (PUF) are soxhlet and ultrasonic extraction. Different conditions were used to analyse the FR via GC-MS. Based on the first results it could be demonstrated that the emission depends on material density and surface condition. The concentrations over time obtained for tris(3-chloropropyl)-phosphate, e.g., from emission test chamber and cell show a good correlation, partly the measured concentration are different. Sampling at elevated temperature gives higher concentrations.
VOC/SVOC-Emissions from materials for flooring installation (primer, screed, adhesive, floor covering) were measured by means of emission test chambers and cells over a time period of at least 28 days at 23 C, 50 % relative humidity and an area specific air flow rate of q = 1.25 m³/m²h. Single components were tested in comparison to three complete structures (same concrete, primer, screed, adhesive) with different types of floor covering (PVC, carpet, linoleum). Sorption into concrete/screed and different sealing by the flooring materials affected the emissions from the complete structures. The complete structures with linoleum and PVC showed the same emissions and emission rates as the flooring materials alone. Emissions from the carpet-covered structure resulted mainly from the lower layers. For two adhesives the formation of secondary emissions (aldehydes and organic acids) was observed starting after the standard testing time of 28 days.