The application of intumescent coatings for fire protection of steel constructions is increasing.
Thanks to the relative thin thickness of the coatings, the typical visual appearance of the
structures can be preserved. In Germany, the applicability of the systems is regulated by the
national as well as European technical approvals. According to the approvals, the application
on steel members in tension is only allowed with limitations. Especially, the application on
solid steel rods in tension is currently not covered. The paper will explain the actual state of
the art of the application of reactive fire protection systems applied to steel structures.
Physical and technical background information will be provided. After that, the latest
scientific results of an on-going research project funded by the German National Institute of
Building Technology (DIBt) and conducted by the Federal Institute for Materials Research
and Testing (BAM) will be described.
Die Verwendung von Endlosfilamenten aus Carbon als Be-wehrungsmaterial für Beton, sogenannter Textilbeton, bietet die Möglichkeit der Sanierung und der Verstärkung bestehender Stahlbetonkonstruktionen. Dabei muss die Frage nach dem Feuerwiderstand von derart verstärkten Tragwerken be-antwortet werden. Aufschluss darüber liefern Brandversuche. Mit Textilbeton verstärkte Stahlbetonplatten haben in Brandversuchen nach der Einheits-Temperaturzeitkurve bei 33 % der Traglast mehr als 60 Minuten standgehalten. Bei 50 % der Traglast kam es nach einer Branddauer von 55 Minuten, bei 65 % nach 30 Minuten, zu einem Zugversagen der textilen Verstärkungsschicht. Bei während des Brandes unbelasteten bzw. gering belasteten Platten lagen die im Anschluss ermittelten Resttragfähigkeiten bei 65 % der Bruchlast nach 30 Minu-ten Branddauer bzw. bei 50 % der Bruchlast nach 60 Minuten Branddauer. Wäh-rend und nach der Beflammung waren zunehmende Durchbiegungen und Rissbreiten erkennbar. Es traten aber keine Abplatzungen auf, weshalb die Ver-stärkungsschicht aus Textilbeton als zusätzliche Betondeckung für die Stahlbe-wehrung angerechnet werden kann. Diese außerordentlich positiven Ergebnisse zeigen, dass für verstärkte Konstruktionen Feuerwiderstandsklassen von F60 bzw. R60 ohne zusätzliche Maßnahmen erreicht werden können. Dies ist von ho-her Relevanz für die wirtschaftliche Anwendung dieser Verstärkungsmethode. Für ein umfassendes Verständnis der Interaktion zwischen den Bewehrungen Textil und Stahl sowie der Versagensmechanismen während des Brandes, sind weitere Erkenntnisse über die mechanischen Eigenschaften von Textilbeton im Hochtemperaturbereich nötig. Auch der Einfluss der Oxidation des Carbons konnte nicht abschließend beurteilt werden. 354 HOTHAN und EHLIG: Hochtemperaturverhalten von Stahlbetonplatten mit TRC-Verstärkung Summary: Using endless carbon filaments for concrete reinforcement, so called textile reinforced concrete, the possibility of reconstruction and strengthening of existing concrete structures arises. The question concerning fire resistance of structures strengthened like this has to be answered. Fire tests provide answers. Steel reinforced concrete slabs strengthened with textile reinforced concrete load-ed with 33 % of ultimate load survived an ISO-fire for 60 minutes. Loaded with 50 % and 65 % of ultimate load the slabs failed after 55 minutes and 30 minutes of fire exposure due to tension failure of the textile reinforcement layer. Slabs not loaded or with a low load level during fire exposure showed remaining bearing resistances of 65 % of ultimate load after 30 minutes and 50 % of ultimate load after 60 minutes of fire exposure. During and after fire exposure rising deflec-tions and growing crack widths were observed. However no spalling occurred. Therefore the textile reinforced concrete layer can be taken into account as con-crete covering for the steel reinforcement. Those extraordinary positive results document, that reinforced concrete structures with additional fibre reinforced concrete can achieve fire resistance classes of R60 without additional provisions. To achieve comprehensive understanding of interaction between steel and fibre reinforcement and failure mechanisms in case of fire more knowledge concerning the mechanic properties of fibre reinforced concrete at high temperatures is es-sential. The influence of oxidation of the carbon fibres could not fully be an-swered.
Thin layers of textile reinforced concrete (TRC) can be used as strengthening for reinforced concrete (RC) slabs or beams to increase their foad-bearing capacity. The concrete matrix consists of a fine-grained concrete with a thickness of 8 to 15 mm. Information on the behaviour of strengthened structures subjected to fire is of particular inlerest for practical applications of this innovative construction method. A total of 7 RC slabs with Steel reinforcement were produced: 2 slabs were used as reference and 5 slabs were strengthened with three layers of textile reinforcement. Ultimate capacity of reference slabs and particular TRC strengthened slabs was determined from statie load results fom 4-point-bending tests.
Fire tests on these slabs were carried out with utilization fectors using a Standard temperature curve (ISO-834-1) for fire testing. Test loads varied between 0 % and 65 % ofuMmate load.
To detect temperatures during fire exposure thermocouples were arranged throughout the cross-section of the slabs. Depending on the utilization the slabs were exposed to fire for 30 minutes or for 60 minutes. In some cases bending fäilure occurred, in other cases the slabs survived. None of the specimens exhibited any visual damage or concrete spalling during fire exposure. Results of deformation measurements and residual strength measurements are presented. Even though mechanisms are not fifily understood, it is important to discuss the presumable reasons for the surprisingiy positive test results. It is presumed tbat the key mechanisms contributing to the outstanding fire resistance capability presented are: superior crack control of the TRC and load redistribution between textile and Steel reinforcement as well as the primary load transfer directly into the slabs.
Reaktive Brandschutzsysteme werden in zunehmendem Maße zum Schutz von sichtbaren Stahlkonstruktionen eingesetzt, weil mit den relativ geringen Beschichtungsdicken das architektonische Erscheinungsbild der Konstruktionen erhalten bleibt. Die Verwendbarkeit der Systeme wird durch nationale und europäische technische Zulassungen geregelt. Die Zulassungen erlauben eine Anwendung auf zugbeanspruchten Bauteilen nur unter Einschränkungen. Eine Verwendung der Systeme auf Zuggliedern mit Vollquerschnitt ist derzeit nicht abgedeckt. Dieser Beitrag beschreibt die aktuelle Situation zur Anwendung reaktiver Brandschutzsysteme und erläutert die physikalisch-technischen Hintergründe. Ferner wird anhand eines Beispiels außerhalb des Anwendungsbereiches der Zulassungen gezeigt, wie eine Anwendung auf Zuggliedern mit rundem Vollquerschnitt im Rahmen einer Zustimmung im Einzelfall ermöglicht werden kann. In einem weiteren Abschnitt werden die jüngsten Forschungsergebnisse aus einem durch das Deutsche Institut für Bautechnik geförderten und durch die Bundesanstalt für Materialforschung und -prüfung bearbeiteten Vorhabens vorgestellt. Das Forschungsvorhaben verfolgt das Ziel, eine Anwendung reaktiver Brandschutzsysteme auf Zuggliedern mit Vollquerschnitten auf Grundlage von Zulassungen allgemein zu ermöglichen.-------------------------------------------------------------------------------------------------------------------------------
The application of intumescent coatings for fire protection of steel constructions is increasing. Thanks to the relative thin thickness of the coatings, the typical visual appearance of the structures can be preserved. The applicability of the systems is regulated by the national German as well as European technical approvals. According to the approvals, the application on steel members in tension is only allowed with limitations. Especially, the application on solid steel rods in tension is currently not yet covered. This contribution first explains the actual state of the art of the application of reactive fire protection systems to steel structures. Technical background information is provided. Furthermore, a case study is presented in order to illustrate the limitations in the scope of the approvals and a possible approach to allow the application of intumescent coatings on solid steel rods via an approval for a specific construction project. After that, the latest scientific results of a research project funded by the German National Institute of Building Technology (DIBt) and conducted by the Federal Institute for Materials Research and Testing (BAM) are described. The objective of the project is to enable the application of intumescent coatings on solid steel rods in tension within the scope of approvals in general.
Die hier vorgestellten Untersuchungen dienen der Erweiterung des Anwendungsbereiches für reaktive Brandschutzsysteme auf Stahlbauteilen im nationalen Zulassungsverfahren.
Für die Wirksamkeit reaktiver Brandschutzsysteme ist die Haftfähigkeit der reaktiven Brandschutzbeschichtung auf dem Untergrund (Stahl) von entscheidender Bedeutung. Die Haftfähigkeit der Beschichtung ist neben der Oberflächenbeschaffenheit und den Eigenschaften des reaktiven Systems selbst im Wesentlichen von der Form des Bauteils und den sich im Brandfall einstellenden erformungen (Krümmungen und Dehnungen) abhängig.
Reaktive Brandschutzsysteme
(2022)
Intumescent fire protection coatings are used to improve the fire resistance of steel members. Due to slender cross-sections typically used for tension members, high demands are placed on the effectiveness and reliability of the intumescent coatings. This paper describes real-scale fire tests of intumescent coatings applied to steel tension members with circular solid and hollow sections. First, the current regulations for the application of intumescent coatings on steel tension members are discussed. After that, a comparison between the foaming behaviour and failure mechanisms of intumescent coatings applied to steel tension members with different cross-sections and loading conditions is given. Next, the experimental setup and procedure of the performed fire tests are presented. In addition, the influences of various parameters on the performance of the intumescent coating are analysed, including the geometry of the steel profile, dry film thickness of the intumescent coating, load utilisation level as well as the orientation of the member. Based on the theoretical considerations and results of the fire tests, it is evidenced that mechanically loaded fire tests are essential to assess accurately the contribution of intumescent fire protection coatings to the fire resistance of steel tension members with circular solid sections.
Intumescent coatings are commonly used in civil engineering to improve the fire resistance of steel constructions. Especially in the case of tension bars, where mostly circular or rectangular solid sections are used, intumescent coatings offer an efficient measure to improve the fire resistance taking advantage of profile-following application and low coating thickness requirements. Thus, the architectural appearance of slender profiles can be preserved. The paper describes real-scale mechanically loaded and unloaded fire tests of circular and rectangular solid steel tension bars with intumescent coating. The aim of these tests is to investigate the influence of the different profile types as well as different bar orientations on the performance of intumescent coatings. The results are used to specify a normative test and assessment procedure to be implemented in a new European standard for determining the contribution of intumescent coatings to the fire resistance of circular or rectangular bars used as tension members.
Reaktive Brandschutzsysteme
(2022)
Die Erkenntnisse zu reaktiven Brandschutzsystemen (RBS) werden kontinuierlich erweitert, was sich in der Entwicklung neuer Produkte und der Ausweitung des durch technische Regelungen abgedeckten Anwendungsbereichs äußert. Der vorliegende Beitrag konzentriert sich auf die Verwendung von RBS auf Stahlkonstruktionen. Neben einer umfassenden Darstellung der aktuellen nationalen und europäischen Regelungen zu RBS, werden technologische Besonderheiten und deren Einfluss auf den Regelungsinhalt im Beitrag thematisiert. Dabei werden neben sich abzeichnenden Neuerungen auch die entsprechenden wissenschaftlich-technologischen Grundlagen dargelegt. Ferner wird die Frage nach der Bewertung der Dauerhaftigkeit von RBS für deutlich über 10 Jahre hinausgehende Zeiträume, und den sich damit einstellenden Feuerwiderstand der Konstruktion behandelt. Der Beitrag schließt mit einer Darstellung zur aktuellen Forschung. Daraus abgeleitet wird ein Ausblick auf zukünftige Forschungsthemen.
Beton, als aktuell am meisten verwendeter Baustoff ist nicht brennbar und weist zudem eine sehr geringe Temperaturleitfähigkeit auf. Er eignet sich somit gut für den baulichen Brandschutz. Jedoch neigt Beton im Brandfall zu explosionsartigen Abplatzungen, die zu einer Reduzierung des tragfähigen Querschnitts und sogar zum Versagen des Bauteils führen können. Derzeit werden thermomechanische und thermohydraulische Schädigungsprozesse als die zwei maßgeblichen Ursachen für explosionsartige Abplatzungen angesehen. Diese Schädigungsprozesse sind unter anderem abhängig von der Prüfkörpergröße, dem Wasser-Zement-Wert, der Porosität, der Permeabilität und dem Bewehrungsgrad des Bauteils.
Im Rahmen des Vortrags werden die Forschungsarbeiten zum Maßstabseffekt des Abplatzverhaltens von Betonen bei Brandbeanspruchung präsentiert. Zu diesem Zweck wurden Betonprüfkörper aus sechs verschiedenen Betonmischungen in jeweils drei Prüfkörpergrößen einseitig, ohne Behinderung der thermischen Ausdehnung und ohne externe Last im Tunnelbrandprüfstand der BAM untersucht. Dieser unikale Prüfstand ermöglicht die Brandprüfung unterschiedlicher Prüfkörpergrößen unter vergleichbaren Brandbedingungen sowie die simultane Prüfung mehrerer kleinformatiger Betonprüfkörper. Das präsentierte, laufende Promotionsvorhaben basiert auf einem von der DFG geförderten Forschungsvorhaben und darauf aufbauenden Folgeuntersuchungen.
Die Ergebnisse des DFG-Vorhabens zeigen einen deutlichen Maßstabseffekt mit einer starken Verringerung der Abplatztiefen bei einer Reduzierung der Prüfkörpergröße. Des Weiteren ist das Abplatzverhalten stark von der Betonmischung abhängig. Vor dem Hintergrund der Ressourcenschonung und Kostenreduzierung verfolgen die auf dem DFG-Vorhaben aufbauenden Untersuchungen das Ziel, das Abplatzverhalten großformatiger Betonprüfkörper durch kleinformatige Betonprüfkörper mit angepassten Randbedingungen nachzustellen. Hierfür wurden zwei Betonmischungen des DFG-Vorhabens verwendet. Die Ergebnisse zeigen, dass durch eine Anpassung der Versuchsrandbedingungen dem Maßstabseffekt entgegengewirkt werden kann.
Um Stahlbauteile im Brandfall vor einer zu schnellen Erwärmung zu schützen, wird häufig auf reaktive Brandschutzsysteme (RBS) zurückgegriffen. Die Produkte eigenen sich besonders aufgrund der profilfolgenden Applikationsmöglichkeit und der vergleichsweise geringen Beschichtungsdicken. Bei einer Brandbeanspruchung schäumt das RBS auf und bildet eine thermische Schutzschicht um das Stahlprofil aus. Dadurch wird die Erwärmung des Stahls verlangsamt und der temperaturbedingte Festigkeitsverlust verzögert, wodurch sich die Feuerwiderstandsdauer des Stahlbauteils verbessert. Aus Brandversuchen ist bekannt, dass die Leistungsfähigkeit von RBS auf Stahlprofilen mit gekrümmter Oberfläche meist schlechter ausfällt als bei vergleichbaren Bauteilen mit ebener Oberfläche. Zum Einfluss der Oberflächenkrümmung auf die thermische Schutzwirkung von RBS werden in dem folgenden Beitrag sowohl theoretische Hintergründe als auch die Ergebnisse aus Brandversuchen an kleinformatigen Probekörpern vorgestellt. Die systematischen Untersuchungen zeigen, dass mit zunehmender Oberflächenkrümmung die Leistungsfähigkeit des RBS tendenziell abnimmt. Bei der Beurteilung der thermischen Schutzwirkung eines RBS sollte die Oberflächenkrümmung eines Bauteils berücksichtigt werden. Die alleinige Fokussierung auf den Profilfaktor eines Stahlprofils ist im Allgemeinen nicht ausreichend. Die Untersuchungen bilden die Grundlage für die Entwicklung von Screening-Tests zur Beurteilung der Eignung von RBS für gekrümmte Oberflächen, wodurch eine Vorauswahl von Produkten für diesen Einsatzzweck ermöglicht wird.
The size effect has its origin in fracture mechanics and describes the formation as well as propagation of cracks in brittle and solid materials in dependence of the specimen size. However, the size effect in concrete spalling describes the damage behaviour on a macroscopic scale for different sized specimens in case of fire. Concrete spalling is a very complex and yet not fully understood phenomenon. To reduce the effort of fire tests to analyse the spalling behaviour of concrete mixtures, this study investigates the susceptibility to spalling for six different concrete mixtures and three specimen sizes. The sizes were divided in full scale slabs (1.8 m x 1.2 m x 0.3 m), intermediate scale cuboids (0.6 m x 0.6 m x 0.3 m) and small scale cylinders (Ø0.15 m x 0.3 m). For this purpose, a novel test set-up was built to test six intermediate scale or twelve small scale specimens simultaneously to ensure a similar heating regime for every specimen. All specimens were fire exposed on one side and remained unrestrained. A size effect occurred for four of the six concrete mixtures. Compared to the full scale specimens the spalling was reduced significantly for all smaller specimen sizes. Additionally, spalling did not occur for the small scale specimens. The results show that the specimen size is an essential parameter to investigate the susceptibility to spalling of a concrete mixture. For future investigations the testing conditions must be adjusted for the intermediate scale specimens to recreate the conditions of the slabs.
Investigating the spalling behaviour of a concrete mixture using large scale members is complex and expensive. Thus, the susceptibility of concrete to spalling is investigated by means of fire tests on small scale specimens. However, the reduction of the fire exposed surface increases the influence of boundary effects. Macrocracking and the water loss via the lateral surfaces reduce the impact of the thermomechanical and thermohydraulic damage mechanisms and therefore, lower the risk of spalling. Thus, the influence of different restraints on the spalling behaviour of intermediate scaled specimens (Ø=0.47 m; h=0.29 m) was investigated for two ordinary concrete mixtures. Both mixtures had the same composition except the type of aggregate. One mixture contained only quartzitic aggregates, whereas the other mixture was made with basalt grit as coarse aggregates. Applied steel rings restrained the thermal expansion of the specimen and prevented the loss of water, whereas applied steel sheet primarily reduced the loss of water during the fire test. Additionally, the fire exposed surface of one specimen of each mixture was pre-dried under controlled climate conditions and fire tested with applied steel rings. The results show a higher spalling volume for the ring restrained specimens compared to the other covering types. Further, the pre-dried boundary zone leads to delayed and decreased occurrence of spalling compared to the non-dried specimens for the concrete with quartzitic aggregates and to a prevention of spalling for the mixture with basalt aggregates. Additionally, the results show that the influence of the thermomechanical behaviour of the coarse aggregates increases with increasing restraint. The restrained conditions of the specimens with applied steel ring are comparable to the conditions in the centre of a large scale member. This test series is a further step for possible concept of steel ring restraint concrete specimens as “screening-tests” in upcoming projects.
Intumescent coatings are used in civil engineering to improve the fire resistance of steel constructions. Due to the thin coating thickness and the profile-following application, the architectural appearance of the steel structure can be preserved. EN 13381-8 provides regulations to determine the contribution to the fire resistance of intumescent coatings applied to steel beams and columns. The scope of this standard excludes tension members and steel members with solid sections. For products that have already been successfully tested and assessed on beams and columns, EN 13381-10 offers the possibility based on unloaded fire tests to extend the scope of application of intumescent coatings to tension bars with solid sections. This approach contradicts the national safety level in Germany, where mechanically loaded testing is mandatory. Therefore, a new part of the test standard series EN 13381 is currently developed to enable the application of intumescent coatings on steel tension bars with solid section based on mechanically loaded fire tests. BAM has already carried out numerous fire tests on loaded steel tension members with intumescent coatings. Currently, in the BAM research project FIRESTEMIC, the influence of the steel bar orientation and the profile type on the thermal performance of intumescent coatings are investigated. Both questions concerning the thermal protection ability of intumescent coatings were analysed based on three different test sets, which were carried out in the tension furnace (Fig. 1a). The fire exposure corresponds to the standard temperature-time curve according to EN 1363-1.
This paper summarises the main findings from the fire tests conducted in the FIRESTEMIC project. The results serve as an experimental background for the proposal of the new standard. Regarding the bar orientation, a new test setup was developed and proposed for the new standard. The two tested commercial water-based intumescent coatings with applied dry film thickness from 1.5 mm to 2.5 mm showed only a slight dependence on the bar orientation. In terms of the steel profile type, circular and rectangular solid sections with identical section factor and applied dry film thickness were tested. It was observed that the circular solid bars with diameter 30 mm heat up faster compared to the solid rectangular bars with dimension 30×30 mm (Fig. 1b). Also at larger steel bars, i.e. diameter 40 mm and dimension 40×40 mm, the same trend occurred. Thus, it is recommended for the new test standard to allow a transfer of the test results from circular to rectangular solid sections. In addition, the paper will describe and explain the test and assessment procedure proposed for the newly developed standard.
Der Beitrag stellt experimentelle Untersuchungen zum Feuerwiderstand von Carbonzuggliedern vor. Die Anwendung von Zuggliedern aus Carbon ist durch die außergewöhnlich gute Ermüdungs- sowie hohe Zugfestigkeit des Werkstoffs motiviert. Ferner ergibt sich gegenüber Stahl eine deutliche Reduzierung des Querschnitts. Perspektivisch sollen damit Stahlzugglieder im Netzwerkbogenbrückenbau ersetzt werden. Durch die Materialsubstitution werden Ressourcen nicht nur beim Zugglied selbst, sondern auch am Gesamttragwerk der Brücke eingespart. Da zum Tragverhalten von Carbonzuggliedern im Brandfall bislang keine Erkenntnisse vorliegen, sollen mit Hilfe von Bauteilbrandversuchen die Versagensmechanismen sowie die grundsätzliche Gleichwertigkeit gegenüber konventionellen Stahlhängern untersucht werden.
Der Beitrag beschreibt die Durchführung und die Ergebnisse von Brandversuchen an mechanisch belasteten Carbonzuggliedern. Die realmaßstäblichen Versuche werden am unikalen Zugbauteil-prüfofen der BAM im Mai 2022 durchgeführt. Das Versuchsprogramm umfasst vier Carbonzugglieder mit kreisrunden Querschnitten in zwei verschiedenen Durchmessern, ⌀36 mm und ⌀51 mm. Aus Gründen der Vergleichbarkeit erfolgt die Brandbeanspruchung nach Einheits-Temperaturzeitkurve (ETK). Während des Brandversuches wird die axiale Prüfkraft von 750 kN bzw. 1500 kN bis zum Eintreten des Probenversagens konstant gehalten. Zusätzlich werden die Längsverformung sowie die Bauteil- und Brandraumtemperaturen aufgezeichnet.
In einem Vorversuch an einem unbelasteten Bauteilabschnitt eines Carbonzuggliedes konnte das Brand- und Erwärmungsverhalten des Verbundmaterials untersucht werden. Dabei zeigten sich Makrorisse und eine Zersetzung der Kunststoffmatrix sowie eine hohe Temperaturbeständigkeit der Kohlenstofffasern. Durch das Fehlen der schützenden Matrix reagierten die Carbonfasern sensibel auf Querbeanspruchung. Dies führte zu einem Bruch und Ablösen der oberflächennahen Fasern.
Der diesjährige Beitrag zeigt den Einfluss ausgewählter Versuchsrandbedingungen auf das Abplatzverhalten von Normalbeton im kleinskaligen Brandversuch. Im Rahmen der Untersuchungen wurde die Abplatzneigung von acht zylindrischen Betonprüfkörpern der Maße Ø47 cm x 29 cm aus Normalbeton analysiert. Vier Prüfkörper wurden aus Normalbeton mit quarzitischer Gesteinskörnung hergestellt, wohingegen die grobe Gesteinskörnung (>2 mm) der anderen vier Prüfkörper durch Basaltsplitt ersetzt wurde. Neben der Art der groben Gesteinskörnung wurden zusätzlich ausgewählte Versuchsrandbedingungen variiert. Dies umfasste zum einen die Vorlagerung der Prüfkörper bei verschiedenen Umgebungsfeuchten und zum anderen die Ummantelung der Prüfkörper mit zwei Ringen aus Stahl bzw. einem durchgehenden Stahlblech. Die Ummantelung der Prüfkörper mit Stahlringen im Brandversuch führt zu einer Behinderung der thermischen Ausdehnung der Prüfkörper und zum Aufbau thermomechanischer Zwangsdruckspannungen. Diese Zwangsdruckspannungen werden maßgeblich von der thermischen Ausdehnung der verwendeten Gesteinskörnung beeinflusst. Zusätzlich wird die Feuchteabgabe über die Mantelfläche behindert. Der Einsatz des Stahlblechs reduziert lediglich die Abgabe der Feuchtigkeit über die Mantelfläche und induziert vernachlässigbare Zwangsdruckspannungen im Beton. Die Brandbeanspruchung der Prüfkörper erfolgte einseitig nach der Einheits-Temperaturzeitkurve (ETK) über einen Zeitraum von 60 Minuten. Mit Hilfe eines Laser Scanners wurden vergleichende 3D-Messungen der brandbeanspruchten Oberfläche vor und nach dem Brandversuch durchgeführt. Aus diesen Messungen konnten das Abplatzvolumen, die Abplatztiefenverteilung und die maximale Abplatztiefe ermittelt werden. Während des Brandversuchs wurde die Temperaturverteilung im Prüfkörper mittels fünf eingebetteter Mantelthermoelemente in verschiedenen Tiefen bestimmt. Die Ergebnisse zeigen, dass die Abplatzungen an der brandbeanspruchten Oberfläche infolge der Prüfkörperummantelung mit Stahlringen bzw. Stahlblech zunehmen. Bei einer Ummantelung mit Stahlringen mit gleichzeitiger Vortrocknung der Betonrandzone platzt der Prüfkörper mit quarzitischer Gesteinskörnung ab, wohingegen der Prüfkörper mit basaltischer Gesteinskörnung keine Abplatzungen aufweist. Dies wird auf die unterschiedliche Ausprägung der thermomechanischen Schädigung infolge der unterschiedlichen thermischen Ausdehnungskoeffizienten von Quarzkies und Basalt zurückgeführt.
Die Ergebnisse der Brandprüfserie zeigen, dass die Variation der Prüfrandbedingungen bei Beibehaltung der Prüfkörpergröße einen maßgeblichen Einfluss auf das Abplatzverhalten haben. Die Randbedingungen sind daher bei kleinskaligen Brandversuchen, die zukünftig als „Screening-Tests“ ersatzweise für kostenintensive Bauteilversuche verwendet werden sollen, zu berücksichtigen.
In civil engineering, steel tension members are normally used for bracings, suspensions and underbracing systems. Typically, slim circular solid sections (CSS) are used for such tension members. However, sufficient knowledge about the performance of reactive fire protection systems (RFPS) applied to solid steel tension members has so far been missing. The application of RFPS on such members was not covered by national German approvals (abZ) as well as European technical assessments (ETA) and therefore only possible by approvals in individual case by the building authority. This paper describes the world’s first scientifically investigated fire tests of RFPS applied to steel tension members with CSS. The influence of various parameters such as profile geometry, dry film thickness of the RFPS, level of the load utilization as well as member orientation was tested. In addition, the foaming and cracking behaviour and thermal protection of the RFPS used are investigated and failure mechanisms are identified. To measure the steel temperature of the tension member without weakening the cross-section a special method for the application of thermocouples was developed. The fire tests show that an application of RFPS on steel tension members with solid section is generally possible. However, due to the slim cross-sections and the missing possibility of load distribution within the tension member, high requirements are placed particularly on the effectiveness and reliability of the RFPS. In particular, the testing of mechanically loaded tension members is essential, since the necessary three-dimensional foaming results in the highest stress level for the RFPS. The findings obtained from the performed fire tests are of general nature. Recommendations for the testing and assessment of RFPS applied to steel tension members with solid section are briefly described in this paper and explained in detail in [1] and [2]. Based on this research, the German building authority (DIBt) has defined national approval guidelines for the testing and the assessment of RFPS applied to tension members with solid section. Since November 2015, a general building approval for a RFPS is available in Germany.
The application of intumescent coatings for fire protection of steel constructions is
increasing. Thanks to the relative thin thickness of the coatings, the typical visual
appearance of the structures can remain essentially unchanged. In Germany, the
applicability of the systems is regulated by the national as well as European technical
assessments. According to the approvals, the application on steel members in tension is
only allowed with limitations. Especially, the application on solid steel rods in tension is
currently excluded from the approval. The paper explains the actual state of the art of the
application of reactive fire protection systems applied to steel structures. Physical and
technical background information are provided. Furthermore, the latest scientific results
of an on-going research project funded by the German National Institute of Building
Technology (DIBt) and conducted by the Federal Institute for Materials Research and
Testing (BAM) will be described.
Über die Entwicklung von Anwendungsregeln für reaktive Brandschutzsysteme auf Stahlzuggliedern
(2014)
Der vorliegende Beitrag stellt den Entwicklungsstand von Anwendungsregeln für reaktive Brandschutzsysteme auf Stahlzuggliedern zusammenfassend dar. Dabei wird insbesondere auf die jüngsten Veränderungen in den normativen Grundlagen und bauaufsichtlichen Regelungen eingegangen und im Hinblick auf Sicherheitsaspekte bewertet.
Die Verringerung der Teilsicherheit für den Bauteilwiderstand nicht stabilitätsgefährdeter Bauteile im Regelwerk für die Kaltbemessung von Stahltragwerken ist hier als besonders kritisch anzusehen, da hierdurch ein systematisches Sicherheitsdefizit für den Brandfall verursacht wird.
Weiterhin werden neuste Forschungsergebnisse bei der Entwicklung von Bewertungsregeln von reaktiven Brandschutzsystemen auf Vollkreisprofilen unter Zugbeanspruchung vorgestellt und diskutiert. Die Untersuchungen behandeln die Fragestellung, inwieweit Prüfungen mit Zugbeanspruchungen an Kreisvollprofilen erforderlich sein werden.
Prüfmethodik für reaktive Brandschutzsysteme auf Stahlzuggliedern mit kreisrundem Vollquerschnitt
(2014)
An der BAM Bundesanstalt für Materialforschung und -prüfung werden Brandversuche an axial belasteten und unbelasteten Zuggliedern mit reaktiver Brandschutzbeschichtung durchgeführt. Neben den für Zugglieder typischen Kreisvollprofilen ist auch ein Kreishohlprofi! untersucht worden. In dieser Veröffentlichung werden Versuchsaufbau und -durchführung sowie die Ergebnisse der bisher durchgeführten Brandversuche vorgestellt. Die bisherigen Brandprüfungen zeigen, dass grundsätzlich eine Anwendung eines herkömmlichen reaktiven Brandschutzsystems auf kreisrunden Stahlprofilen möglich ist. Jedoch ergeben sich aufgrund des gekrümmten Querschnittes Besonderheiten, welche bei der Prüfung dieser Systeme und deren späteren Anwendung zu berücksichtigen sind. Unter anderem ist besonders bei kleinen Trockenschichtdicken mit einer ausgeprägten Längsrissbildung im aufgeschäumten Brandschutzsystem zu rechnen, welche die thermische Schutzwirkung des Systems erheblich beeinträchtigt. Neben Rissen in Längsrichtung treten auch Querrisse im Brandschutzsystem auf. Anhand der Versuche zeigt sich, dass die aufgebrachte mechanische Zugbelastung die Rissbildung begünstigt. Das Versagen der belasteten Zugglieder ereignet sich meist in der Nähe der gemessen maximalen Stahltemperatur und kündigt sich durch eine Zunahme und Vergrößerung der Querrisse an. Im Allgemeinen führt eine Erhöhung der Trockenschichtdicke bzw. eine Reduzierung des Lastausnutzungsgrades zu einer Verbesserung des Feuerwiderstandes. Ein Unterschied in den Temperaturverläufen von belasteten und unbelasteten Versuchskörpern ist besonders bei geringen Schichtdicken zu beobachten.
Im Bauwesen werden für Zugglieder häufig Kreisvollprofile mit relativ kleinen Durchmessern eingesetzt. Diese Bauteile bestehen in der Regel aus gezogenem, kaltverformtem Blankstahl. Aufgrund des Herstellungsverfahrens kommt es zu einer Veränderung der Materialeigenschaften des Stahls. Für Blankstahl sind in der Norm [1] keine temperaturabhängigen Materialkennwerte angegeben. An der BAM Bundesanstalt für Materialforschung und -prüfung wurden im Rahmen eines Forschungsvorhabens [2] die mechanischen Hochtemperatureigenschaften von Stahlzuggliedern aus kaltverformtem Blankstahl der Festigkeitsklasse S355 untersucht. Als Ausgangsmaterial wurde ein Kreisvollprofil mit einem Durchmesser von 20 mm verwendet. Für den Blankstahl wurden die chemische Zusammensetzung, der Elastizitätsmodul, die Spannungs-Dehnungs-Kennlinien sowie der Wärmeausdehnungskoeffizient bestimmt. Ziel der Untersuchungen war es herauszufinden, welche materialspezifischen Besonderheiten kaltverformter Blankstahl unter Brandeinwirkung gegenüber anderen Stählen besitzt und inwieweit sich die in der Norm [1] für warmgewalzten Baustahl angegebenen Werte auf Blankstahl übertragen lassen. Die Ergebnisse der Materialuntersuchungen werden zudem für die numerische Nachrechnung von Brandversuchen an Stahlzuggliedern mit reaktiver Brandschutzbeschichtung verwendet.--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
Mechanical properties of cold drawn steel S355 at elevated temperatures used for tension rods. In construction, circular solid steel rods with relatively small diameter are often used for tensile elements. These elements are usually made of cold drawn steel. As a result of the manufacturing process, the material properties of the steel are changed. In the standard [1], no information regarding the temperature-dependant material properties of cold drawn steel are given. At BAM Federal Institute for Materials Research and Testing, a research project [2] was conducted to investigate the mechanical properties at elevated temperatures of tension elements made of cold drawn steel type S355. In the experiments, the tensile specimens were produced from a circular solid profile with a diameter of 20 mm. Within the research project, the chemical composition, the modulus of elasticity, the stress-strain-relationships and the thermal expansion coefficient were determined. The aim of this investigation was to identify the specific material characteristics of cold drawn steel under fire exposure. Furthermore, a comparison between cold drawn steel and the commonly used in construction hot-rolled steel was done, in order to clarify whether the material properties of hot rolled steel that are given in the standard [1] can be also used for cold drawn steel. The results of the material tests are used as input values for a numerical simulation of fire tests on tension elements with reactive fire protection systems.
Das Forschungsvorhaben verfolgt im Wesentlichen das Ziel, die Anwendbarkeit von reaktiven Brandschutzsystemen auf Zugstabsystemen auf Grundlage von allgemeinen bauaufsichtlichen Zulassungen zu ermöglichen. Zu diesem Zweck sollen neben versuchstechnischen Beurteilungsverfahren auch rechnerische Nachweismöglichkeiten im Rahmen der sogenannten Heißbemessung entwickelt werden.
Aktuelle Entwicklungen zur Anwendung reaktiver Brandschutzsysteme auf filigranen Stahlzuggliedern
(2016)
Im Stahlbau wird die feuerwiderstandserhöhende Wirkung reaktiver Brandschutzsysteme (RBS) bereits seit Jahrzehnten erfolgreich und mit stetig wachsender Nachfrage genutzt. Mehrjährige Forschungen an der Bundesanstalt für Materialforschung und -prüfung (BAM) haben dazu geführt, dass in Deutschland eine zulassungsbasierte Anwendung reaktiver Brandschutzsysteme auf Stahlzuggliedern mit Vollprofil möglich ist.
Spannbeton-Hohlplatten (engl.: Hollow Core Slabs, HC-Platten) werden insbesondere aus wirtschaftlichen Gründen als Deckensysteme im Hochbau eingesetzt. Bei einem 2007 aufgetretenen Brandereignis in einem Parkhaus in Rotterdam kam es zu einer teilweisen Ablösung des unteren Plattenspiegels. Dies hatte eine europaweite Diskussion zur brandschutztechnischen Bewertung dieser Bauart zur Folge. Mittlerweile liegen eine Vielzahl von gutachterlichen Stellungnahmen, Literaturauswertungen und auch jüngeren Forschungsarbeiten zum Feuerwiderstand von Konstruktionen aus Spannbeton-Hohlplatten vor. In den Untersuchungen wurde unter anderem das Tragverhalten von HC-Platten bei starrer Auflagerung, insbesondere hinsichtlich der Querkrafttragfähigkeit, analysiert. Ein weiterer, bei der Prüfung und Bewertung von Spannbeton-Hohlplatten bisher kaum beachteter Aspekt ist die im Brandfall auftretende Behinderung der Querdehnung. In der Praxis kann für HC-Platten eine Querdehnungsbehinderung im Brandfall auftreten, wenn beispielsweise eine sehr steife Begrenzung des brandbeanspruchten Deckenbereichs vorliegt, z. B. durch Treppenhauskerne oder auch durch umgebende Deckenfelder bei lokaler Brandbeanspruchung. Um dieser Fragestellung nachzugehen, wurden an der BAM entsprechende experimentelle und numerische Untersuchungen an Deckenfeldern aus Spannbeton-Hohlplatten mit unterschiedlicher seitlicher Zwängung durchgeführt. Im Beitrag werden die im Realmaßstab durchgeführten Brandversuche ausführlich beschrieben und deren Ergebnisse und daraus abgeleiteten Erkenntnisse vorgestellt. Die an der BAM durchgeführten Untersuchungen haben gezeigt, dass bei einer Zunahme der seitlichen Zwängung die Horizontalrissbildung in den Plattenstegen zu- und die Längsrissbildung abnimmt. Trotz der ausgeprägten Horizontalrissbildung kam es in den Brandversuchen nicht zu- einer Ablösung des unteren Plattenspiegels. Ebenso zeigte sich kein negativer Einfluss der Horizontalrisse auf das Trag- und Verformungsverhalten der brandbeanspruchten Deckenkonstruktion. Die Ergebnisse aus den Brandversuchen stehen zukünftig zur Validierung numerischer Modelle zur Verfügung.
Steel tension rod systems consist of tension rods, fork connectors and associated intersection or connecting plates. They are used for truss systems, bracings or suspensions owing to slender design and increased economic efficiency. In case of fire, beside the tension rods themselves, the connection parts require appropriate fire protection. The use of intumescent fire protection coatings prevents a rapid heating of the steel and helps to ensure the load-carrying capacity of the structures. Because the connection components of the tension rod systems feature surface curvature as well as a complex geometry, high demand is placed on the intumescence and thermal protection effectiveness of the reactive fire protection coatings. Experimental studies were carried out to investigate the performance of intumescent coatings applied to the components of tension rod systems. The examined aspects include the foaming and cracking behaviour of the intumescent coatings, the influence of different dry film thicknesses (DFT), the heating rate of the steel connecting parts in comparison to the tension rods, as well as the mounting orientation of the tension rods together with their associated fork connectors. The results show that a decrease in the surface curvature and/or an increase in the mass concentration of the steel components lead to a lower heating rate of the steel. Moreover, the performance of the intumescent coating on tension rod systems is influenced by the mounting orientation of the steel components.
Reaktive Brandschutzsysteme können die Feuerwiderstandsdauer von Stahlbauteilen signifikant erhöhen. Im Brandfall schäumt das reaktive Brandschutzsystem auf und bildet um das Stahlbauteil eine thermische Schutzschicht aus. Dadurch wird die Erwärmung des Stahls verlangsamt und der temperaturbedingte Festigkeitsverlust verzögert. Reaktive Brandschutzsysteme werden überwiegend in drei Bereichen angewendet: Hochbau, Offshore bzw. maritimer Sektor sowie Tank- bzw. Behälterbau. Insbesondere bei Stahltanks und -behältern sind häufig einfach oder auch doppelt gekrümmte Bauteiloberflächen anzutreffen. Aufgrund des meist begrenzten seitlichen Expansionsvermögens von reaktiven Brandschutzsystemen kann es bei Bauteilen mit konvexer Oberflächenkrümmung zu einer Intensivierung der Rissbildung im Schaum kommen, wodurch sich häufig die thermische Schutzwirkung verschlechtert. Da zum Thema des Einflusses der Oberflächenkrümmung auf die Leistungsfähigkeit reaktiver Brandschutzsysteme bisher kaum Untersuchungen vorliegen, wurden exemplarisch zwei Tankböden mit zwei verschiedenen Trockenschichtdicken eines reaktiven Brandschutzsystems einer Brandprüfung unterzogen. Bei gleicher Trockenschichtdicke des reaktiven Brandschutzsystems zeigten die Tankböden eine wesentlich schnellere Erwärmung als ebene Stahlplatten mit vergleichbarem Profilfaktor. Die Brandprüfungen und die Ergebnisse zum Einfluss der Oberflächenkrümmung werden im Beitrag ausführlich vorgestellt und diskutiert.
Die Erkenntnisse zu reaktiven Brandschutzsystemen (RBS) werden kontinuierlich erweitert, was sich in der Entwicklung neuer Produkte und der Ausweitung des durch technische Regelungen abgedeckten Anwendungsbereichs äußert. Der hier vorliegende Beitrag konzentriert sich auf die Verwendung von RBS auf Stahlkonstruktionen. In den vergangenen zehn Jahren wurden, abgesichert durch neue Erkenntnisse aus der Forschung, die Anwendung auf Stahlzuggliedern mit offenem Profil präzisiert und im Rahmen allgemeiner bauaufsichtlicher Zulassungen (abZ) neu geregelt. Ferner wurde die Grundlage geschaffen, die Anwendung von RBS auf Zuggliedern mit kreisrundem Vollprofil zu bewerten und auf Basis der abZ zu ermöglichen. Neben einer umfassenden Darstellung der aktuellen nationalen und europäischen Regelungen zu RBS, werden technologische Besonderheiten und deren Einfluss auf den Regelungsinhalt im Beitrag thematisiert. In der jüngsten Vergangenheit stellt sich mit zunehmender Dringlichkeit die Frage nach der Bewertung der Dauerhaftigkeit von RBS für lange Zeiträume, wobei damit Nutzungsdauern weit jenseits der in den nationalen und europäischen Regelungen bereits etablierten 10 Jahre gemeint sind. In diesem Zusammenhang ist zu klären, wie der Feuerwiderstand von Konstruktionen zu bewerten ist, die bereits über lange Zeiträume mit RBS versehen sind.
Spalling of concrete due to fire exposure can lead to severe damage of building components. It is a much discussed subject in structural engineering and not yet completely understood. Generally, it is assumed that thermohydraulic and thermomechanical processes induce tensile stresses in the concrete. Furthermore, the tensile strength of concrete is reduced due to increasing temperatures. The combination of an increasing tensile stress and a decreasing tensile strength result in the occurrence of explosive spalling. The spalling behaviour of concrete is influenced by many parameters, for instance the water cement ratio, porosity, permeability of concrete as well, the presence of steel reinforcement and polypropylene fibres, also the size and geometry of the fire exposed area. Within the current research project at Bundesanstalt für Materialforschung und prüfung (BAM), the susceptibility to spalling of six different concrete mixtures is analysed to quantify the size effect using small scale, intermediate scale and full scale tests. A special fire test setup was built to test specimens simultaneously to enable a better comparability. All specimens are tested without additional mechanical load and unrestraint to prevent external induced cracking at the fire exposed site. Thermocouples are used to measure in situ the temperature distribution as an indication on the thermal degradation of the concrete during the fire tests. Afterwards the maximum spalling depth and the damaged area of the specimen are illustrated by a photogrammetric measurement system. The contribution to the spalling workshop presents the results of four concrete mixtures tested in intermediate-scale and full-scale fire tests. The comparisons are based on the concrete temperature as well as the obtained photogrammetric data. The results show that the spalling depth and the spalling area are significantly affected by the size of the fire exposed area.
Purpose – The purpose of this paper is to investigate the performance of intumescent coating on tension rod systems and their components. Steel tension rod systems consist of tension rods, fork end connectors and associated intersection or gusset plates. In case of fire, beside the tension rods themselves, the connection parts require appropriate fire protection. Intumescent fire protection coatings prevent a rapid heating of the steel and help secure the structural load-carrying capacity. Because the connection components of tension rod systems feature surface curvature and a complex geometry, high demand is placed on the intumescence and thermal protection performance of the coatings.
Design/methodology/approach – In this paper, experimental studies were carried out for steel tension rod systems with intumescent coating. The examined aspects include the foaming and cracking behaviour, the influence of different dry film thicknesses, the heating rate of the steel connecting parts in comparison to the tension rods, and the mounting orientation of the tension rods together with their fork end connectors.
Findings – The results show that a decrease in surface curvature and/or an increase inmass concentration of the steel components leads to a lower heating rate of the steel. Moreover, the performance of the intumescent coating on tension rod systems is influenced by themounting orientation of the steel components.
Originality/value – The findings based on fire tests contribute to a better understanding of the intumescent coating performance on connection components of tension rod systems. This subject has not been extensively studied yet.
Die Feuerwiderstandsdauer von ungeschützten Stahlbauteilen lässt sich durch den Einsatz reaktiver Brandschutzsysteme (RBS) signifikant erhöhen. Durch den profilfolgenden Auftrag der Brandschutzbeschichtung und die hierfür erforderlichen geringen Trockenschichtdicken, welche in der Regel nur wenige Millimeter betragen, können neben den brandschutz¬technischen Anforderungen auch die an die Stahl-konstruktion gestellten gestalterischen Ansprüche erfüllt werden. Kommt es zu einem Brandereignis schäumt das reaktive Brandschutzsystem auf und bildet eine thermische Schutzschicht um das Stahlbauteil aus. Dadurch wird die Erwärmung des Stahls verlangsamt und der Festigkeitsverlust infolge Temperatur wird verzögert. Die Anwendung von reaktiven Brandschutzsystemen auf Stahlbauteilen wird im Allgemeinen durch Zulassungen geregelt. In Bezug auf die durch die Zulassung abgedeckte Verwendung von reaktiven Brandschutzsystemen auf zug¬beanspruchten Stahlbauteilen haben sich in den letzten Jahren verschiedene Änderungen ergeben. Der nachfolgende Beitrag gibt hierzu einen aktuellen Überblick und beschreibt die Hintergründe, welche zu den neuen Regelungen geführt haben. Ferner erfolgt in diesem Zusammenhang ein Ausblick auf noch zu untersuchende Fragestellungen, welche bisher noch nicht durch die Regelungen in den Zulassungen abgedeckt werden. Darüber hinaus wird in dem Beitrag die derzeit aktuelle Problematik bezüglich der Alterungsbeständigkeit von reaktiven Brandschutz¬systemen thematisiert.
Ziel der Forschung ist die experimentelle und numerische Untersuchung des Brandverhaltens von HC-Platten unter besonderer Berücksichtigung des Einflusses der Querdehnungsbehinderung (seitliche Zwängung). Eine starke Querdehnungsbehinderung der HC-Platten kann in der Praxis aus der Konstruktionsart resultieren, z.B. durch an das Deckenfeld angrenzende steife Treppenhauskerne. Eine teilweise Querdehnungsbehinderung tritt auf, wenn die thermische Ausdehnung lokal brandbeanspruchter HC-Platten durch angrenzende nicht beflammte Deckenbereiche behindert wird. Da bisher keine Untersuchungen zu dieser Fragestellung vorlagen, wurden Großbrandversuche mit Deckenfeldern aus HC-Platten bei unterschiedlichem Grad der Querdehnungsbehinderung durchgeführt.
Im Stahlbau wird die feuerwiderstandserhöhende Wirkung reaktiver Brandschutzsysteme (RBS) bereits seit Jahrzehnten erfolgreich und mit stetig wachsender Nachfrage genutzt. Die Anwendung dieser Systeme wird durch Zulassungen geregelt. Die Ermittlung des Beitrages reaktiver Brandschutzsysteme zur Feuerwiderstandsdauer von Stahlbauteilen wird in der Regel mit Hilfe von mechanisch belasteten und unbelasteten Brandversuchen beurteilt. Ein entsprechendes Prüf- und Bewertungsverfahren war bisher für Träger und Stützen, jedoch nicht für Zugglieder vorhanden. Mehrjährige Forschungen, haben in Deutschland zur Entwicklung eines neuen Prüf- und Bewertungsverfahrens geführt, so dass der durch Zulassungen geregelte Anwendungsbereich reaktiver Brandschutzsysteme auf filigrane Stahlzugglieder, insbesondere mit Vollprofil, erweitert werden konnte. Der Beitrag beschreibt die Besonderheiten und Herausforderungen für den Einsatz von reaktiven Brandschutzsystemen auf filigranen Stahlzuggliedern, die wesentlichen Einflussparameter sowie die maßgebenden Versagensmechanismen. Ferner wird gezeigt, wie anhand von Brandversuchen, Materialuntersuchungen im Hochtemperaturbereich und numerischen Simulationen das neue Prüf- und Bewertungsverfahren entwickelt, validiert und angewendet wurde. Abschließend erfolgt ein Ausblick auf noch zu untersuchende Fragestellungen, z. B. hinsichtlich der Bauteilorientierung sowie zum Umgang mit den Anschlussbauteilen von Stahlzuggliedern.
Die Feuerwiderstandsdauer von ungeschützten Stahlbauteilen lässt sich durch den Einsatz reaktiver Brandschutzsysteme (RBS) signifikant erhöhen. Durch den profilfolgenden Auftrag der Brandschutzbeschichtung und die hierfür erforderlichen geringen Trockenschichtdicken, welche in der Regel nur wenige Millimeter betragen, können neben den brandschutztechnischen Anforderungen auch die an die Stahlkonstruktion gestellten gestalterischen Ansprüche erfüllt werden. Kommt es zu einem Brand, schäumt das reaktive Brandschutzsystem auf und bildet eine thermische Schutzschicht um das Stahlbauteil aus. Dadurch wird die Erwärmung des Stahls verlangsamt und der Festigkeitsverlust infolge Temperatur wird verzögert. Die Verwendung von reaktiven Brandschutzsystemen auf Stahlbauteilen wird durch Zulassungen geregelt. In Bezug auf den durch die Zulassung geregelten Anwendungsbereich von reaktiven Brandschutzsystemen auf zugbeanspruchten Stahlbauteilen haben sich in den vergangenen Jahren verschiedene Änderungen ergeben. Der nachfolgende Beitrag gibt hierzu einen aktuellen Überblick und beschreibt die Hintergründe, welche zu den neuen Regelungen geführt haben. Ferner erfolgt in diesem Zusammenhang ein Ausblick auf noch zu untersuchende Fragestellungen, welche bisher noch nicht durch die Regelungen in den Zulassungen abgedeckt werden. Bei den nachfolgenden Ausführungen handelt es sich um einen Auszug des Beitrages für die 18. EIPOS-Sachverständigentage Brandschutz.
In this paper, a nonlinear three-dimensional finite element (FE) model was developed and validated to study the effect of seismic damage location on the response of concrete filled tube (CFT) columns at fire after earthquakes. Three analyses were conducted consecutively in the modelling, namely, cyclic, thermal and structural. Results of the cyclic loading analysis comprising residual deformations were applied as the Initial condition to the thermal-stress model, replicating the seismic performance of column.
Following, a nonlinear sequentially coupled-thermal stress Analysis was carried out to investigate the fire response of CFT columns after the seismic event. Three damage scenarios were contemplated, considering any possible potential damages that could be generated by the earthquake loading on CFT columns. The accuracy of the proposed FE model was examined by comparing the numerical results with that of available tests on fire and cyclic loading. By means of the validated model, the performance of damaged CFT columns was then investigated under fire after earthquakes. The level of damage was assumed as a high damage level, presuming that the column reached 50% of ist lateral resistance while still maintaining its overall stability after the earthquake. The results were presented broadly, including the axial deformation history as well as the fire resistance time for CFT columns. To have a comprehensive insight on the influence of damage location in columns, the fire response of damaged specimens was compared with that of an intact one.
In this study, a nonlinear three-dimensional finite element (FE) model was developed and validated to investigate the response of concrete filled tube (CFT) columns subjected to post-earthquake fires. Three steps were considered successively in the modelling, namely, cyclic, thermal and structural analyses. Outputs from the cyclic loading including residual deformationswere imposed as an initial condition to the thermal-stress model, imitating the seismic response of the column. Subsequently, a nonlinear sequentially thermal-stress analysis was conducted to simulate the fire response of column after the earthquake. The proposed FE model was validated by comparing the simulation resultswith the observations of full-scale fire and cyclic tests available in the literature.
The validated numericalmodelwas then used to study the behavior of CFT columns under the combined action of earthquake and fire as a multi-hazard event. Three probable seismic damage scenarios were considered in the column, namely, middle length, bottom and top end region damages. The level of damage was assumed as a high damage level, presuming that the column reached 50% of its lateral resistance while still maintaining ist overall stability after the earthquake. The results showed that the top and bottom end region damages have not significantly influence the fire response of the damaged column. Besides, the column with the middle span damage performed a lesser fire resistance time owing to the coincidence of damage location to that of onset of global buckling.
Zur brandschutztechnischen Ertüchtigung von Stahlkonstruktionen werden reaktive Brandschutzsysteme aufgrund der geringen Beschichtungsdicken und der profilfolgenden Applikation in zunehmendem Maße eingesetzt. Da die für Zugstabsysteme eingesetzten Bauteile meist eine stark konvex gekrümmte Oberfläche aufweisen und der Anschlussbereich über eine vergleichsweise komplexe Geometrie verfügt, stellt dies besonders hohe Anforderungen an die Leistungsfähigkeit von reaktiven Brandschutzsystemen. Anhand von realmaßstäblichen Brandversuchen wurden das Aufschäumungs- und Rissverhalten, der Einfluss der Trockenschichtdicke, die Erwärmung der einzelnen Stahlbauteile sowie der Einfluss der Bauteilorientierung untersucht. Die Ergebnisse zeigen, dass eine Abnahme der Oberflächenkrümmung oder eine Erhöhung der Massenkonzentration der Stahlbauteile zu einer geringeren Aufheizrate des Stahls führt. Darüber hinaus ist festzustellen, dass die Leistungsfähigkeit des reaktiven Brandschutzsystems von der Bauteilorientierung der Zugstabsysteme beeinflusst wird. Die durchgeführten Brandversuche können zur Entwicklung geeigneter Prüfszenarien für die Beurteilung von reaktiven Brandschutzsystemen auf Zugstabsystemen und deren Anschlusskonstruktionen verwendet werden, wodurch eine Erweiterung des zulassungsbasierten Anwendungsbereichs ermöglicht wird.
Spannbeton-Hohlplatten (engl.: hollow core slabs, HC-Platten) werden insbesondere aus wirtschaftlichen Gründen als Deckensysteme im Hochbau eingesetzt. Bei einem 2007 aufgetretenen Brandereignis in einem Parkhaus in Rotterdam kam es zu einer teilweisen Ablösung des unteren Plattenspiegels. Dies hatte eine europaweite Diskussion zur brandschutztechnischen Bewertung dieser Bauart zur Folge. Mittlerweile liegen eine Vielzahl von gutachterlichen Stellungnahmen, Literaturauswertungen und auch jüngeren Forschungsarbeiten zum Brandverhalten von Konstruktionen aus Spannbeton-Hohlplatten vor. In den Untersuchungen wurde unter anderem das Tragverhalten von HC-Platten bei starrer Auflagerung, insbesondere hinsichtlich der Querkrafttragfähigkeit, untersucht.
Ein weiterer bei der Prüfung und Bewertung von Spannbeton-Hohlplatten bisher kaum beachteter Aspekt ist die im Brandfall auftretende Behinderung der Querdehnung. Um zu untersuchen inwieweit die Tragfähigkeit der HC-Platten von der Querdehnungsbehinderung beeinflusst wird, wurden an der BAM entsprechende experimentelle und numerische Untersuchungen an Deckenfeldern aus Spannbeton-Hohlplatten mit variierender seitlicher Zwängung durchgeführt. In der Praxis kann für HC-Platten eine Querdehnungsbehinderung im Brandfall auftreten, wenn beispielsweise eine sehr steife Begrenzung des brandbeanspruchten Deckenbereiches vorliegt, z.B. durch Treppenhauskerne oder auch durch umgebende Deckenfelder bei lokaler Brandbeanspruchung. Im Beitrag werden die im Realmaßstab durchgeführten Brandversuche ausführlich beschrieben und deren Ergebnisse und daraus abgeleiteten Erkenntnisse vorgestellt.
Anhand der an der BAM durchgeführten Untersuchungen konnte gezeigt werden, dass bei einer Zunahme der seitlichen Zwängung die Horizontalrissbildung in den Plattenstegen zu und die Längsrissbildung abnimmt. Die unterschiedlich starke, thermisch bedingte horizontale Verformung der Plattenober- und -unterseite bewirkte aufgrund der Dehnungsbehinderung am Übergang zur seitlichen Zwängungskonstruktion eine Schubbeanspruchung in Plattenquerrichtung. Die Schubspannung wurde durch Horizontalrissbildung in den Plattenstegen abgebaut. Trotz der ausgeprägten Horizontalrissbildung kam es in den Brandversuchen nicht zu einer Ablösung des unteren Plattenspiegels. Ebenso zeigte sich kein negativer Einfluss der Horizontalrisse auf das Trag- und Verformungsverhalten der brandbeanspruchten Deckenkonstruktion. Die in den Brandversuchen erfassten thermischen und mechanischen Messwerte sowie die Ergebnisse aus Materialuntersuchungen stehen zukünftig als umfangreiche Datenbasis für die Validierung numerischer Modelle zur Verfügung.
Deckensysteme aus Spannbeton-Hohlplatten (engl.: Hollow Core Slabs, HC-Platten) werden im Hochbau insbesondere aus wirtschaftlichen Gründen eingesetzt. Vorteile gegenüber Massivdecken in Ortbetonweise ergeben sich insbesondere aus dem hohen Vorfertigungsgrad, geringem Eigengewicht und der Möglichkeit großer Spannweiten bei relativ niedrigen Querschnitten. Bei einem 2007 aufgetretenen Brandereignis in einem Parkhaus in Rotterdam kam es infolge Horizontalrissbildung in den Plattenstegen zu einer teilweisen Ablösung des unteren Plattenspiegels. Dies hatte eine europaweite Diskussion zur brandschutztechnischen Bewertung dieser Bauart zur Folge. Mittlerweile liegen gutachterliche Stellungnahmen, Literaturauswertungen und auch jüngere Forschungsarbeiten zum Feuerwiderstand von Konstruktionen aus Spannbeton-Hohlplatten vor. In den Untersuchungen wurde unter anderem das Tragverhalten von HC-Platten bei starrer Auflagerung, insbesondere hinsichtlich der Querkrafttragfähigkeit, untersucht.
Ein bei der Prüfung und Bewertung von Spannbeton-Hohlplatten bisher kaum beachteter Aspekt ist die im Brandfall auftretende Behinderung der Querdehnung infolge umgebender Bauteile oder Tragwerksteile. Im Bauwerk kann für HC-Platten eine Querdehnungsbehinderung im Brandfall auftreten, wenn eine steife Begrenzung des brandbeanspruchten Deckenbereiches vorliegt, z.B. durch Treppenhauskerne oder auch durch umgebende Decken-felder bei lokaler Brandbeanspruchung. Ferner legten Versuchsergebnisse nahe, dass eine Aufbetonschicht die Zwängungen in der HC-Platte verstärkt. Die Problematik der Querdehnungsbehinderung im Brandfall wurde auch in Gremien der Bauaufsicht sowie im zuständigen Sachverständigenausschuss des Deutschen Instituts für Bautechnik (SVA 463 Tragwerksbemessung für Brandeinwirkung) erörtert. Dabei wurde anhand vorgelegter Studien und numerischer Voruntersuchungen deutlich, dass die Bildung von Horizontalrissen in den Plattenstegen auch bei HC-Platten ohne Aufbeton auftreten kann.
Um den Einfluss der Querdehnungsbehinderung zu klären wurden an der BAM entsprechende experimentelle und numerische Untersuchungen an Decken-feldern aus Spannbeton-Hohlplatten mit unterschiedlichem Grad der seitlichen Zwängung durchgeführt. Im Beitrag werden die im Realmaßstab durch-geführten Brandversuche beschrieben und deren Ergebnisse und daraus abgeleiteten Erkenntnisse vorgestellt.
Die Erkenntnisse zu reaktiven Brandschutzsystemen (RBS) werden kontinuierlich erweitert, was sich in der Entwicklung neuer Produkte und der Ausweitung des durch technische Regelungen abgedeckten Anwendungsbereichs äußert. Der hier vorliegende Beitrag konzentriert sich auf die Verwendung von RBS auf Stahlkonstruktionen. In den vergangenen zehn Jahren wurden, abgesichert durch neue Erkenntnisse aus der Forschung, die Anwendung auf Stahlzuggliedern mit offenem Profil präzisiert und im Rahmen allgemeiner bauaufsichtlicher Zulassungen (abZ) neu geregelt. Ferner wurde die Grundlage geschaffen, die Anwendung von RBS auf Zuggliedern mit kreisrundem Vollprofil zu bewerten und auf Basis der abZ zu ermöglichen.
Neben einer umfassenden Darstellung der aktuellen nationalen und europäischen Regelungen zu RBS, werden technologische Besonderheiten und deren Einfluss auf den Regelungsinhalt im Beitrag thematisiert.
In der jüngsten Vergangenheit stellt sich mit zunehmender Dringlichkeit die Frage nach der Bewertung der Dauerhaftigkeit von RBS für lange Zeiträume, wobei damit Nutzungsdauern weit jenseits der in den nationalen und europäischen Regelungen bereits etablierten 10 Jahre gemeint sind. In diesem Zusammenhang ist zu klären, wie der Feuerwiderstand von Konstruktionen zu bewerten ist, die bereits über lange Zeiträume mit RBS versehen sind. Nicht zuletzt stellt sich die Frage nach der Dauerhaftigkeit der Systeme selbst und adäquaten Prüfverfahren zu deren Beantwortung. Neue und bereits etablierte
Ansätze werden vorgestellt und diskutiert.
Der Beitrag schließt mit einer Darstellung der aktuellen Forschung. Neben den Forschungsaktivitäten zur Dauerhaftigkeit sind hier insbesondere Untersuchungen zur Anwendung und Bewertung von RBS auf Grundlage von Naturbränden und extremen Brandereignissen genannt. Neuste Untersuchungen befassen sich auch mit der Anwendung von RBS auf komplexen Geometrien wie auch auf anderen Substraten wie Beton, Aluminium und faserverstärkten Kunststoffen sowie hybriden Werkstoffen. Die hybriden Werkstoffe aus der Kombination von Metallen und Verbundwerkstoffen sind derzeit vorwiegend im Behälter-, Fahrzeug- und Flugzeugbau anzutreffen. Auch die bereits vor Jahrzehnten begonnenen Aktivitäten zur Entwicklung rechnerischer Verfahren zur Beurteilung der Wirkungsweise von RBS werden in der aktuellen Forschung fortgeführt und weiterentwickelt.
Die Erkenntnisse zu reaktiven Brandschutzsystemen (RBS) werden kontinuierlich erweitert, was sich in der Entwicklung neuer Produkte und der Ausweitung des durch technische Regelungen abgedeckten Anwendungsbereichs äußert. Der hier vorliegende Beitrag konzentriert sich auf die Verwendung von RBS auf Stahlkonstruktionen. In den vergangenen zehn Jahren wurden, abgesichert durch neue Erkenntnisse aus der Forschung, die Anwendung auf Stahlzuggliedern mit offenem Profil präzisiert und im Rahmen allgemeiner bauaufsichtlicher Zulassungen (abZ) neu geregelt. Ferner wurde die Grundlage geschaffen, die Anwendung von RBS auf Zuggliedern mit kreisrundem Vollprofil zu bewerten und auf Basis der abZ zu ermöglichen.
Neben einer umfassenden Darstellung der aktuellen nationalen und europäischen Regelungen zu RBS, werden technologische Besonderheiten und deren Einfluss auf den Regelungsinhalt im Beitrag thematisiert.
In der jüngsten Vergangenheit stellt sich mit zunehmender Dringlichkeit die Frage nach der Bewertung der Dauerhaftigkeit von RBS für lange Zeiträume, wobei damit Nutzungsdauern weit jenseits der in den nationalen und europäischen Regelungen bereits etablierten 10 Jahre gemeint sind. In diesem Zusammenhang ist zu klären, wie der Feuerwiderstand von Konstruktionen zu bewerten ist, die bereits über lange Zeiträume mit RBS versehen sind. Nicht zuletzt stellt sich die Frage nach der Dauerhaftigkeit der Systeme selbst und adäquaten Prüfverfahren zu deren Beantwortung. Neue und bereits etablierte Ansätze werden vorgestellt und diskutiert.
Der Beitrag schließt mit einer Darstellung der aktuellen Forschung. Neben den Forschungsaktivitäten zur Dauerhaftigkeit sind hier insbesondere Untersuchungen zur Anwendung und Bewertung von RBS auf Grundlage von Naturbränden und extremen Brandereignissen genannt. Neuste Untersuchungen befassen sich auch mit der Anwendung von RBS auf
komplexen Geometrien wie auch auf anderen Substraten wie Beton, Aluminium und faserverstärkten Kunststoffen sowie hybriden Werkstoffen. Die hybriden Werkstoffe aus der Kombination von Metallen und Verbundwerkstoffen sind derzeit vorwiegend im Behälter-, Fahrzeug- und Flugzeugbau anzutreffen. Auch die bereits vor Jahrzehnten begonnenen Aktivitäten zur Entwicklung rechnerischer Verfahren zur Beurteilung der Wirkungsweise von RBS werden in der aktuellen Forschung fortgeführt und weiterentwickelt.
Das Forschungsprojekt fokussiert sich auf die Untersuchung des Einflusses der Querdehnungs-behinderung auf das Trag- und Verformungsverhalten von Spannbeton-Hohlplatten (HC-Platten) im Brandfall. Das Vorhaben wird vom Deutschen Institut für Bautechnik (DIBt) finanziell gefördert und von der Bundesanstalt für Materialforschung und -prüfung (BAM) durchgeführt. Der Forschungs¬bericht beinhaltet eine Literaturrecherche, numerische Simulationsberechnungen, realmaßstäbliche Brandversuche an Deckenfeldern aus HC-Platten sowie Materialuntersuchungen für den verwendeten Beton. In numerischen Simulationen wurden sowohl einzelne HC-Platten als auch ganze Deckenfelder unter mechanischer Belastung und Brandbeanspruchung analysiert. Realmaßstäbliche Brandversuche mit Beanspruchung nach Einheits-Temperaturzeitkurve und auflagernaher Einleitung der mechanischen Prüflast (Querkraftbeanspruchung) wurden an insgesamt drei Deckenfeldern durchgeführt. Die Deckenfelder wurden aus 5 m langen HC-Platten zusammengesetzt. In zwei Brandversuchen wurden einachsig gespannte Deckenfelder untersucht. In dem einen Versuch waren die Längsränder frei, in dem anderen an der Querdehnung gehindert. In einem dritten Brandversuch wurde ein zweiachsig gespanntes Deckenfeld mit seitlicher Dehnungsbehinderung untersucht. Um das Verhalten der HC-Platten im Brandversuch quantitativ beschreiben zu können, wurde eine umfangreiche Sensorik zur Erfassung thermischer und mechanischer Kenngrößen eingesetzt.
Die Brandversuche haben gezeigt, dass bei einer Zunahme des Grades der seitlichen Dehnungsbehinderung die Horizontalrissbildung in den Plattenstegen zu und die Längsrissbildung abnimmt. Die unterschiedlich starke thermisch bedingte horizontale Verformung der Plattenober- und -unterseite bewirkte am Übergang zur seitlichen Zwängungskonstruktion eine Schub-beanspruchung in Plattenquerrichtung. Die Schubspannung wurde durch Horizontalrissbildung in den Plattenstegen abgebaut. Trotz der ausgeprägten Rissbildung kam es in den Brandversuchen nicht zu einer Ablösung des unteren Plattenspiegels. Ebenso zeigte sich kein negativer Einfluss der Horizontalrisse auf das Trag- und Verformungsverhalten der brandbeanspruchten Decken-konstruktion. Die in den Brandversuchen erfassten thermischen und mechanischen Messwerte sowie die Ergebnisse aus Materialuntersuchungen stehen zukünftig als umfangreiche Datenbasis für die Validierung numerischer Modelle zur Verfügung.
Der Beitrag beschreibt die Entwicklung eines neuartigen in situ Nachweisverfahrens zur Beurteilung des Feuerwiderstandes von bestehenden Stahlkonstruktionen mit gealtertem reaktivem Brandschutzsystem (RBS). Derzeit ist ein solcher Nachweis ausschließlich anhand eines Bauteilbrandversuchs möglich. Hierzu muss ein Bauteil aus der Bestandskonstruktion entnommen und einer zerstörenden Brandprüfung unterzogen werden. In Zusammenhang mit der Dauerhaftigkeitsbewertung von RBS für Zeiträume von mehr als 10 Jahren besteht in der Praxis vermehrt der Bedarf an einem minimal invasiven Prüfverfahren, mit dessen Hilfe sich direkt am Bestandsbauwerk die tatsächlich vorhandene Leistungsfähigkeit des gealterten RBS überprüfen lässt. Durch einen erfolgreichen Funktionsnachweis wäre eine Weiternutzung der Bestandkonstruktion bei Aufrechterhaltung des bestehenden Sicherheitsniveaus möglich.
Die Anwendung von Zuggliedern aus Carbon ist durch die außergewöhnlich gute Ermüdungs- sowie hohe Zugfestigkeit des Werkstoffs motiviert. Ferner ergibt sich gegenüber Stahl eine deutliche Reduzierung des Querschnitts. Perspektivisch sollen damit u. a. Stahlzugglieder im Netzwerkbogenbrückenbau ersetzt werden. Das Tragverhalten von Carbonzuggliedern im Brandfall ist jedoch bislang unbekannt. Daher wurden mittels Bauteilbrandversuchen die Versagensmechanismen untersucht sowie anhand gewonnener Versuchsdaten eine exemplarische Einschätzung zur Gleichwertigkeit gegenüber konventionellen Stahlzuggliedern vorgenommen. Der Beitrag beschreibt realmaßstäbliche Brandversuche an mechanisch belasteten Carbonzuggliedern, die im Rahmen des Verbundforschungsvorhabens NeZuCa durchgeführt wurden. Das Versuchsprogramm umfasste vier Carbonzugglieder mit kreisrunden Querschnitten in zwei verschiedenen Durchmessern, 36 mm und 51 mm. In Ermangelung eines präskriptiven Brandszenarios für den im Projekt vorgesehenen Anwendungsfall und aus Gründen der Vergleichbarkeit erfolgte die Brandbeanspruchung nach Einheitstemperaturzeitkurve (ETK). Neben den Längsverformungen der Zugglieder wurden auch die Bauteil und Brandraumtemperaturen aufgezeichnet.
Ziel des Forschungsvorhabens ist es, ein standardisiertes Prüf- und Bewertungsverfahren zur Bestimmung des Beitrags reaktiver Brandschutzsysteme (RBS) zum Feuerwiderstand von Stahlzuggliedern zu erarbeiten und dieses in ein Entwurfsdokument für eine europäische Prüfnorm zu überführen. Hierzu wurden einerseits bereits vorhandene Erfahrungen und Erkenntnisse genutzt und andererseits mittels Brandversuchen neue Prüfdaten zur Beantwortung bisher offengebliebener Aspekte zum Einfluss der Bauteilorientierung und Profilart erzeugt und ausgewertet. Dadurch wird die prüftechnische Grundlage für eine sichere, zulassungsbasierte Anwendung von reaktiven Brandschutzsystemen auf zugbeanspruchten Stahlbauteilen gelegt und ein einheitliches Sicherheitsniveau etabliert.
Der im Rahmen des Forschungsprojektes entwickelte Normentwurf wurde mit den Fachexperten der zuständigen nationalen und europäischen Normungsgremien diskutiert und abgestimmt. Das erarbeitete Prüf- und Auswertungsverfahren basiert auf der Durchführung von Brandversuchen an mechanisch belasteten Stahlzuggliedern mit RBS. Ergänzend sind unbelastete Brandversuche zur Beurteilung des Einflusses der Bauteilorientierung sowie der Eignung bei Schwelbrandbeanspruchung möglich. Die im Projekt durchgeführten experimentellen Untersuchungen liefern die Grundlage für den im Normenentwurf vorgeschlagenen Prüfaufbau der mechanisch belasteten und unbelasteten Brandversuche. Ferner konnte durch die Untersuchungen gezeigt werden, dass sich unter bestimmten Voraussetzungen die Prüfergebnisse von Stahlzuggliedern mit Kreisvollprofil ohne zusätzliche Brandversuche auf entsprechende Zugglieder mit Rechteckvollprofil übertragen lassen. Darüber hinaus konnte belegt werden, dass die Leistungsfähigkeit eines RBS aufgrund unterschiedlicher Bauteilorientierungen abnehmen kann und daher zwingend beim Anwendungsbereich des RBS zu berücksichtigen ist. Hierzu wird ein Temperaturdifferenz-kriterium vorgeschlagen, bei dessen Einhaltung die Wirksamkeit des RBS bei von der horizontalen Referenzorientierung abweichenden Bauteilneigungen noch gleichwertig gegeben ist. Andernfalls bietet der Normenentwurf die Möglichkeit die reduzierte thermische Schutzwirkung des RBS im Assessment zu berücksichtigen.
Die Ergebnisse aus dem Forschungsvorhaben wurden bereits auf einem wissenschaftlichen Symposium vorgestellt sowie in einer referierten Fachzeitschrift publiziert. Ferner wurden die Informationen zum Forschungsprojekt und dem Normenentwurf im Rahmen eines Anwenderworkshops interessierten Kreisen zugänglich gemacht. Der im Projekt ausgearbeitete Normenentwurf wird dem zuständigen europäischen Normungsgremien, CEN/TC 127/WG 1, zur Verfügung gestellt und dort zur Abstimmung gestellt.
Understanding the susceptibility to spalling of concrete members in case of fire is important to evaluate the residual load-bearing capacity. The investigations of the spalling phenomenon of a concrete mixture using real scale members are necessary but expensive to carry out. Reducing the specimen size leads to an increase of boundary effects that can result in a reduced spalling or absence of spalling. In this study, fire tests were carried out on unrestrained, single-sided exposed, cuboid shaped specimens (0.6 m x 0.6 m x 0.29 m) as well as unrestrained and steel ring restrained cylindrical specimens (Ø = 0.47 m, h = 0.29 m), which induce different boundary conditions. These fire tests were carried out on two ordinary concrete mixtures. The two mixtures differ only in the type of aggregates (quartz gravel and basalt grit) and were used to investigate the influence of the thermal expansion of the aggregate on the spalling behaviour of the concrete. The results show a significant increase of
the spalling depth due to the restrained thermal expansion achieved by the applied steel rings. Additionally, the type of aggregate has a direct influence on the spalling behaviour of a concrete mixture. The reduction of the boundary effects by the steel rings recreate the test conditions in the centre of a large concrete member. Thus, this type of specimen is suitable to determine the susceptibility to spalling of a material (screening-tests) as preliminary investigations to full scale fire tests.
Im Rahmen des Forschungsprojektes IGF 20470N wurden Untersuchungen zum Alterungsverhalten von reaktiven Brandschutzsystemen (RBS) auf Stahlbauteilen durchgeführt. Mithilfe der Ergebnisse einer umfangreichen Literaturrecherche sowie experimentellen und numerischen Untersuchungen sollte ein Vorschlag für ein Prüfkonzept zum Nachweis einer Nutzungsdauer von RBS von mehr als 10 Jahren auf Basis von Kurzzeitversuchen abgeleitet werden. Dabei setzt die Bewertung des Alterungsverhaltens von RBS voraus, dass die Mechanismen der Alterung hinreichend bekannt sind.
Dafür wurden zunächst systematisch Daten von Kurz- und Langzeitversuchen von nationalen Zulassungsprüfungen der letzten Jahrzehnte ausgewertet. Anschließend wurden umfangreiche experimentelle Untersuchungen an einer wasserbasierten sowie einer epoxidharzbasierten Richtrezeptur durchgeführt. Da aus der Literatur bekannt ist, dass die Einflüsse der Bewitterung zu einer Veränderung der Konzentration der Bestandteile innerhalb der Beschichtung führen können, wurden Untersuchungen mit Mangelrezepturen durchgeführt, wobei systematisch einzelne Bestandteile reduziert wurden. Neben optischen Untersuchungen wurden thermoanalytische Verfahren (DSC-TG-, ATR-FTIR-, Elementar-, Farbanalyse) angewandt sowie Brandversuche an beschichteten Stahlplatten durchgeführt. Des Weiteren wurden die Richtrezepturen den beschleunigten Kurzzeitversuchen gemäß EAD 350402-00-1106 (2017) unterzogen, welche die Zulassung von Produkten auf europäischer Ebene regelt. Für die wasserbasierte Richtrezeptur wurden die Bewitterung für den feuchten Innenraum (Typ Z1) mehrfach wiederholt (1x, 3x, 6x). Für die epoxidharzbasierte Richtrezeptur entsprach die Bewitterung dem Zyklus für die Außenanwendung (Typ X). In Brandversuchen sowie thermoanalytischen und optischen Untersuchungen wurde das Alterungsverhalten sowie die thermische Schutzwirkung analysiert.
Anschließend wurden numerische Simulationen von Stahlbauteilen mit gealterten RBS durchgeführt und anhand der experimentellen Untersuchungen validiert. Mithilfe der numerischen Modelle kann eine Bewertung der thermischen Schutzwirkung von Stahlbauteilen mit gealterten RBS vorgenommen werden.
Mithilfe der gesammelten Erkenntnisse wurde ein Vorschlag für ein Prüfkonzept für den Nachweis einer Nutzungsdauer von mehr als 10 Jahren abgeleitet. Das Prüfkonzept besteht dabei aus einem Katalog von Möglichkeiten, die aktuellen Zulassungsprüfungen auf europäischer Ebene für eine Nutzungsdauer von 10 Jahren auf einen längeren Zeitraum zu erweitern.
Nowadays there are intumescent coatings available for diverse applications. There is no established assessment of their protection performance besides the standard time-temperature curve, but natural fire scenarios often play an important role. A reliable straightforward performance-based assessment is presented. The effective thermal conductivity per thickness is calculated based on intermediate-scale fire tests. The optimum thermal insulation, the time to reach it, and the time until contingent failure of the coating are used for an assessment independent of the heating curve. The procedure was conducted on four different commercially intumescent coatings for steel construction, one solvent-based, one waterborne, one epoxy-based, and a bandage impregnated with a waterborne coating. The performance was studied under four different but similar shaped heating curves with different maximum temperatures (standard time-temperature curve, hydrocarbon curve and two self-designed curves with reduced temperature). The thermal protection performance is crucially affected by the residue morphology. Therefore, a comprehensive morphology analysis, including micro-computed tomography and scanning electron microscopy, was conducted on small-scale residues (7.5 x 7.5 cm2). Two different types of inner structures and the residue surface after different heat exposures were discussed in terms of their influence on thermal protection performance.
Reaktive Brandschutzsysteme finden im baulichen Brandschutz Anwendung zur Erhöhung des Feuerwiderstands von Stahlkonstruktionen. Neben den Anforderungen an die Feuerwiderstandsdauer können damit auch Ansprüche an die Ästhetik erfüllt werden. Die profilfolgende Applikation und die geringen Trockenschichtdicken der Produkte ermöglichen es, das filigrane Erscheinungsbild von Stahlkonstruktionen aufrechtzuerhalten. Neben der thermischen Schutzwirkung muss auch die Dauerhaftigkeit der Brandschutzbeschichtung sichergestellt werden. Die Bewertungsmethoden, die auf europäischer Ebene durch das EAD 350402-00-1106 zur Verfügung stehen, zielen auf eine Nutzungsdauer von zehn Jahren ab. Prüfverfahren für einen darüber hinausgehenden Zeitraum sind nicht beschrieben. In diesem Beitrag werden experimentelle Untersuchungen zum Einfluss der Bewitterung auf das Expansionsverhalten, zur thermischen Schutzwirkung und zu den während des Aufschäumens im Brandfall stattfindenden Reaktionen vorgestellt. Die Versuche wurden an einem wasserbasierten und einem epoxidharzbasierten reaktiven Brandschutzsystem durchgeführt. Die Ergebnisse wurden im Rahmen des IGF-Forschungsvorhabens 20470 N erzielt.