Filtern
Dokumenttyp
- Zeitschriftenartikel (14)
- Vortrag (11)
- Posterpräsentation (5)
- Beitrag zu einem Sammelband (1)
- Beitrag zu einem Tagungsband (1)
Schlagworte
- XPS (7)
- NEXAFS (5)
- ToF-SIMS (5)
- SIMS (4)
- Ionic liquids (3)
- SEM (3)
- Data fusion (2)
- EDX (2)
- Reference material (2)
- Surface analysis (2)
Organisationseinheit der BAM
Eingeladener Vortrag
- nein (11)
Argon cluster sputtering of an organic multilayer reference material consisting of two organic components, 4,4'-bis[N-(1-naphthyl-1-)-N-phenyl- amino]-biphenyl (NPB) and aluminium tris-(8-hydroxyquinolate) (Alq3), materials commonly used in organic light-emitting diodes industry, was carried out using time-of-flight SIMS in dual beam mode. The sample used in this study consists of a ~400-nm-thick NPB matrix with 3-nm marker layers of Alq3 at depth of ~50, 100, 200 and 300 nm. Argon cluster sputtering provides a constant sputter yield throughout the depth profiles, and the sputter yield volumes and depth resolution are presented for Ar-cluster sizes of 630, 820, 1000, 1250 and 1660 atoms at a kinetic energy of 2.5 keV. The effect of cluster size in this material and over this range is shown to be negligible.
We report a surface analytical study of poly(methyl methacrylate) (PMMA) microparticles (beads) with a grafted shell of poly(acrylic acid) (PAA) with thicknesses up to 4 nm using scanning electron microscopy (SEM), X-ray photoelectron spectroscopy (XPS), time-of-flight secondary ion mass spectrometry (ToF-SIMS), and near-edge X-ray adsorption fine structure (NEXAFS) spectroscopy. These polymer microparticles were analyzed before and after reaction of the surface carboxyl (CO2H) groups with 2,2,2-trifluoroethylamine (TFEA) to gain a better understanding of methods with use of covalently bound probe molecules for surface group analysis. The results obtained with chemical derivatization XPS using TFEA are discussed in terms of surface quantification of reactive CO2H groups on these PAA-coated microparticles. A labeling yield of about 50% was found for TFEA-derivatized particles with amounts of surface-grafted CO2H groups of 99 µmol/g or more, which is consistent with predicted reaction yields for homogeneously dispersed PAA hydrogels.
The surfaces of polymeric dialyzer membranes consisting of polysulfone and polyvinylpyrrolidone were investigated regarding the lateral distribution and quantitative surface composition using time-of-flight secondary-ion-mass-spectrometry and x-ray photoelectron spectroscopy. Knowledge of the distribution and composition on the outer surface region is of utmost importance for understanding the biocompatibility of such dialyzer membranes. Both flat membranes and hollow fiber membranes were studied.
Process control of thin organic-inorganic (multi)layer systems using TOF-SIMS assisted with PCA
(2014)
Room temperature ionic liquids (RTIL) are composed of ions only and are defined as molten salts with a melting point below 100°C1. They have numerous interesting physical properties such as high thermal stability, a wide liquid range and a tuneable viscosity. Besides their low melting points they have also a very low vapour pressure, which enables their analysis in ultra high vacuum devices such as XPS2, 3 and ToF-SIMS2, 4. A systematic study with different ionic liquids was carried out by means of time-of-fight secondary-ion-mass-spectrometry in positive and negative ion mode. Thereby a variation of the anion in 1-butyl-3-methylimidazolium based ionic liquids, a variation of the cation including a variation of the side chain length, in bis(triuoromethylsulfonyl)imide based ionic liquids was taken into account. The compounds were measured under bismuth cluster ion (Bi7+) bombardment, and spectral information and general rules for the fragmentation pattern are presented. Evidence for cation-anion interactions (e.g. hydrogen bonding), due to high molecular secondary cluster ions, could be found. The interaction strength could be estimated by ToF-SIMS via correlation of the secondary anion intensity to secondary cluster ion intensity ratio with donor and acceptor numbers.