This sequence of X-Ray images shows how one of the most common Italian moka pots actually work! The sequence starts with a completely prepared moka pot (water in the bottom part, coffee in the middle and hot plate on). During the process the water starts to boil and the steam pressure pushes the hot water through the coffee into the bassin at the top of the pot.
This video sequence and additional explanations can also be found on Wikipedia.
The objects of this investigation were sculptures taken from a ca. three hundred years old baroque epitaph of a church in Tonning, a town in Northern Germany. Around 1900 it was found in a disastrous state heavily damaged by wood-worm. At that time, the whole artwork was treated with the tar extract carbolineum as a remedy. Nowadays, this substance has been identified as carcinogenic, and its presence can be perceived by its stench and visually at certain spots on the surface where it has penetrated the covering paint.
A gold-painted sculpture of a massive wooden skull was interrogated with X-rays and fast neutrons to investigate the internal distribution of the carbolineum. The X-ray tomography, with its excellent spatial resolution revealed galleries left over from the worm infestation in the outer areas and cracks in the central region. The golden color coating appeared as a thick and dense layer. In comparison the tomography with fast neutrons, though being of lower resolution and yet unresolved artefacts revealed sections of slightly different densities in the bulk of the wood. These differences we attribute to the differences in the distribution of the impregnant in the wood, visible due to its higher hydrogen content making it less transparent for neutrons.
Im Rahmen des Basisprojektes »Sammlungserschließung« wurden im Oktober 2014 Radiographien von 14 Gemälden und zwei Schmuckrahmen aus der Sammlung Modebild – Lipperheidesche Kostümbibliothek (Kunstbibliothek, Staatliche Museen zu Berlin) erzeugt.
Die Aufnahmen wurden von Anja Schönstedt, Bernhard Redmer und Stefan Hohendorf von der Bundesanstalt für Materialforschung und -prüfung (BAM, Fachbereich 8.3 Radiologische Verfahren) angefertigt und uns zur weiteren Bearbeitung bereitgestellt.
Radiologic evaluation techniques are nondestructive testing (NDT) used to detect the bulk of explosives and contraband materials in large objects. As compared to conventional low-energy (<450 key) X-ray imaging, high-energy (>1 MeV) digital X-ray radiography is required for the NOT of large containers because of the need for high penetration through thick materials, sensitivity, and the ability to distinguish between low-and high-Z materials. Mobile, high-energy, and high-resolution radiologic techniques are useful to detect contraband and threat materials in digital radiographic images of containers with complex packing. This paper presents a mobile, high-energy X-ray radiographic technique for the in-field nondestructive inspection of cargo containers. The developed experimental technique consisted of a betatron as a high-energy (7.5 MeV) X-ray source and a high-resolution (400 mu m) matrix detector for the digital X-ray imaging. In order to evaluate the detection efficiency and image quality of the measurement technique, a test specimen was proposed that was made of a 3 mm thick steel container with an inner dimension of 60 x 30 x 40 cm(3) comprising different low-and high-Z materials. Image quality indicators were used to assess the essential image quality parameters such as image basic spatial resolution, effective attenuation coefficient, and signal-to-noise ratio (SNR). Experimental investigations were performed on a 6.1 m sea freight container with mockup dangerous materials in complex packing. Preliminary experimental results showed that the proposed technique was able to distinguish between liquids and solids, as well as detect contraband materials. Furthermore, a remarkable SNR of 400 was achieved in the measured digital X-ray images. The influence of temperature on X-ray radiation dose rate at different X-ray energies was also investigated. Finally, important applications of the proposed technique in the context of maritime security are discussed.
In the context of the German aviation security research and development project SILUFRA (secure air freight transport chains), BAM has developed a high-resolution and high-energy X-ray imaging technology for the reliable detection of dangerous and illicit materials in densely packed air freight containers. In the developed technology, a novel combination of high-energy (2-7.5 MeV) X-ray betatron as the radiation source and a high-resolution digital detector array (DDA) for the X-ray imaging was utilized to improve the probability of detecting contraband and explosive materials by enhancing the spatial and contrast resolution in the digital X-ray image. In addition, flexible rotations of the high-energy X-ray source and the digital detector array can lead to clarify the suspicious region of interest (ROI) in air freight containers efficiently. Thus, reduces the false alarm rates and the need for expensive manual inspections of the whole container load. In order to evaluate the detection efficiency, we carried out the experimental investigations on a real air freight container loaded with typical cargo materials such as heavy automobile components and electronic products as well as mock-up dangerous and contraband materials. Furthermore, the material discrimination in the radiographic images was evaluated based on the dual high-energy X-ray imaging method. Finally, important applications of the proposed imaging technology to the air cargo security are discussed
Trotz strenger gesetzlicher Regelungen kommt es immer wieder zu schwerwiegenden Unfällen und Mängeln beim Transport und der Lagerung von Gefahrgütern. Die Ursachen dafür sind oft technisches, aber auch menschliches Versagen. Nicht zu unterschätzen ist die ständig wachsende Anzahl von Gefahrguttransporten auf deutschen Straßen. Waren 2002 noch 126 Mio. t Fracht mit Gefahrguttransporten im Straßenverkehr unterwegs, stieg die Frachtmenge im Jahr 2008 bereits auf 171 Mio. t. In den letzen Jahren ereigneten sich nach Angaben des statistischen Bundesamtes etwa 300 schwere Unfälle, an denen Gefahrguttransporte beteiligt waren. Allein 2009 wurden 1 372 Unfälle mit wassergefährdenden Stoffen registriert, wobei insgesamt 376 000 l wassergefährdende Stoffe freigesetzt wurden.
Ziel ist die Entwicklung eines universellen Monitoringmoduls für Gefahrgutbehälter, das während der gesamten Nutzungsdauer am Behälter verbleibt. Durch die Auswertung verschiedener Messwerte, die vom Modul erfasst werden, kann die Sicherheit bei Gefahrguttransporten erhöht und das Unfallrisiko verringert werden. Weiterhin können Rückschlüsse über die Sicherheit und den Zustand des Behälters gezogen werden (Alter, Verschleiß, frühere Inhalte, Überschreitung von Spezifikatonsgrenzen).
Seit der Antike gehört die Medea-Sage zu den bekanntesten Geschichten der Weltliteratur. Der berühmte französische Künstler Carle Van Loo hat sich dieses Epos um 1759 angenommen und ein beeindruckendes Ölgemälde mit Abmessungen von 2,30x3,28m² erschaffen. Mit Mademoiselle Clairon als Medea und Henri Louis Le Kain als Jason ist ein Kunstwerk entstanden, das seitdem einige Veränderungen und Restaurierungen erfahren hat.
Die Bundesanstalt für Materialforschung und -prüfung (BAM) hatte 2020 die Möglichkeit, dieses und ein zweites Kunstwerk, im Neuen Palais in Potsdam, für die Stiftung Preußische Schlösser und Gärten Berlin-Brandenburg, radiografisch zu untersuchen. Hierbei wurden sowohl technologisch als auch kunsthistorisch einige interessante Entdeckungen gemacht, die im vorliegenden Beitrag vorgestellt werden.
This work presents the use of limited experimental measurements to develop a set of calibrated Simulation parameters that can then be used for reliable simulation of subsea pipeline inspections. The modelling software aRTist is used as the simulation tool, and the calibration is through comparison with experimental images of a well characterised sample in a water tank. Image Quality parameters such as signal-to-noise ratio, contrast and basic spatial resolution are compared with the aim of matching simulated values to experimental results. Currently the model is partially calibrated, with signal-to-noise ratio successfully matched while differences are still found in contrast-to-noise ratio comparisons. This means that measurements depending on absolute intensity are not accurate enough in the simulation at this stage. However, the simulation is found to be accurate for wall thickness measurements in tangential images, which are not based on absolute intensity, with simulated and experimental cases producing similar results.
This work presents an investigation of the accuracy of a radiographic simulation model applied to subsea pipeline inspections. Experimental measurements of a sample in a water tank are used to develop a set of calibrated simulation parameters for the modelling software aRTist. Image quality parameters such as signal-tonoise ratio, contrast and basic spatial resolution are compared with the aim of matching simulated values to experimental results. With this method signal-to-noise ratio was successfully matched while differences were still found in contrast-to-noise ratio comparisons. This means that measurements depending on absolute intensity are not accurate enough, however wall thickness measurements in tangential images, which are not based on absolute intensity, were found to produce similar results in simulated and experimental cases. The differences in contrast and intensity are thought to be due to detector backscatter and additional scatter from out-of-setup objects within the exposure bay, due to a lack of source collimation. These would affect the experimental results but were not included in the simulated setup. This was investigated by including different proportions of peripheral water and other objects in the modelled setup and examining the effect on Image quality parameters. Results show that this additional scatter has a significant impact on the radiograph, particularly on image contrast, and is therefore the likely cause of differences between experimental and simulated images. This implies that it will be very difficult to completely match simulated to experimental results, as including all possible scattering objects in the model would be very complex. An improvement could be made by using real subsea data to estimate this additional scattering, which could then be used to calibrate the model. However there would still be significant uncertainty in the ability of the model to accurately produce realistic intensity and contrast.