Compared to the designated European upper reference level of 300 Bq m-3 for indoor radon concentrations, the contribution of building materials appears to be low. Taking into account the recommended limit of 100 Bq m-3 by WHO as well as the increased dose conversion factor, the contribution of building products is quite relevant, especially at low air change rates. Therefore in Germany a maximum contribution of building materials to the indoor radon concentration of 20 Bq m-3 is discussed.
Because measurements of low concentrations are associated with high uncertainties, radon exhalation rates are often determined in chambers without air exchange and indoor conditions are extrapolated.
This study investigated the suitability of direct low level radon measurement under simulated indoor conditions with commercially available instruments, based on the preliminary EU standard for the determination of the emission of volatile organic compounds (VOC) from building materials in test chambers.
Measurements are possible with a relative uncertainty ranging from 7 to 18 %. Four major problems were identified:
1. Detector sensitivity: Two of four instruments were identified to determine low radon concentrations in a sufficiently short measuring time.
2. Thoron discrimination: Thoron was discriminated by aging the sampled air in a hose before the detector.
3. Sampling setup: An external chamber measurement was feasible as long as all main system parts were under slight overpressure.
4. Blank value: For VOC-emission testing ambient air, conditioned by filtration and sorption, is used to generate an air exchange. Regarding radon, this treatment is non-effective. If all instrument background levels have been characterized, the blank value must be measured with a second detector in parallel.
Compared to the designated European upper reference level of 300 Bq/m³ for indoor radon concentrations, the contribution of building materials appears to be low. Taking into account the recommended limit of 100 Bq/m³ by WHO as well as the increased dose conversion factor, the contribution of building products is quite relevant, especially at low air change rates. Therefore in Germany a maximum contribution of building materials to the indoor radon concentration of 20 Bq/m³ is discussed.
Because measurements of low concentrations are associated with high uncertainties, radon exhalation rates are often determined in chambers without air exchange and indoor conditions are extrapolated.
This study investigated the suitability of direct low level radon measurement under simulated indoor conditions with commercially available instruments, based on the preliminary EU standard for the determination of the emission of volatile organic compounds (VOC) from building materials in test chambers.
Measurements are possible with a relative uncertainty ranging from 7 to 18%. Four major problems were identified:
1. Detector sensitivity: Two of four instruments were identified to determine low radon concentrations in a sufficiently short measuring time.
2. Thoron discrimination: Thoron was discriminated by aging the sampled air in a hose before the detector.
3. Sampling setup: An external chamber measurement was feasible as long as all main system parts were under slight overpressure.
4. Blank value: For VOC-emission testing ambient air, conditioned by filtration and sorption, is used to generate an air exchange. Regarding radon, this treatment is non-effective. If all instrument background levels have been characterized, the blank value must be measured with a second detector in parallel.
The presentation gives a brief overview of the main goals, the used methods and the first results of the PMARS OdourSense project. In cooperation with the Moulay Ismaïl University in Meknès (Morocco), a multi-gas sensor system for odour nuisance monitoring in outdoor air and a method for testing/calibration of such devices are being developed in this project.
In this paper, we introduce a nano aerial robot swarm for Indoor Air Quality (IAQ) monitoring applications such as occupational health and safety of (industrial) workplaces. The robotic swarm is composed of nano Unmanned Aerial Vehicles (UAVs), based on the Crazyflie 2.0 quadrocopter, and small lightweight Metal Oxide (MOX) gas sensors for measuring the Total Volatile Organic Compound (TVOC), which is a measure for IAQ. An indoor localization and positioning system is used to estimate the absolute 3D position of the swarm similar to GPS. A test scenario was built up to validate and optimize the swarm for the intended applications. Besides calibration of the IAQ sensors, we performed experiments to investigate the influence of the rotor downwash on the gas measurements at different altitudes and compared them with stationary measurements. Moreover, we did a first evaluation of the gas distribution mapping performance. Based on this novel IAQ monitoring concept, new algorithms in the field of Mobile Robot Olfaction (MRO) are planned to be developed exploiting the abilities of an aerial robotic swarm.
The presence of wastewater and air pollution has become an important risk factor for citizens, not only in terms of problems related to health risks, but also because of its negative impact on the country's image. For this reason, malodorous emission monitoring and control techniques are in high demand in urban areas and industries. The aim of this work is first to build an electronic nose (e-nose) and a Voltammetric Electronic tongue (VE-tongue) in order to study their ability to discriminate between polluted and clean environmental samples. Secondly, Thermal Desorption-Gas Chromatography-Mass Spectrometry (TD-GC-MS), and Solid Phase Micro Extraction-Gas Chromatography–Mass Spectrometry (SPME-GC-MS) are utilized to explain this discrimination by identifying specific compounds from these samples. Indeed, the e-nose, consisted of metal oxide semiconductor gas sensors, is used for the assessment of the studied odorous air and headspace samples from water and wastewater sites. Moreover, the VE-tongue, based on metal electrodes, is utilized to determine the patterns of the sensor array responses, which serve as fingerprints profiles of the analyzed liquid samples. Chemometric tools, such as Principal Component Analysis (PCA), Hierarchical Cluster Analysis (HCA), and Support Vector Machines (SVMs) are operated for the processing of data from the e-nose and the VE-tongue. By using the both systems, the analyses of headspace and liquid samples from the seven sites allow better discrimination. To explain the cause of the obtained discrimination, TD-GC-MS and SPME-GC-MS analyses are well performed to identify compounds related sites. According to these outcomes, the proposed e-nose and VE-tongue are proved to be rapid and valuable tools for analysis of environmental polluted matrices.
This study investigated the adaptation of the state-of-the-art test procedure for the determination of emissions of volatile organic compounds (VOC) from materials into indoor air to test for the radon exhalation from stony construction products. A complete robustness validation including all relevant parameters showed that the procedure can be well applied by testing institutes already holding available the required VOC testing infrastructure that solely needs to be complemented by calibrated commercial radon measurement instrumentation. When measurements of the radon exhalation from construction materials become mandatory by law, test capacity can easily be applied. This work can serve as a recommendation for the European standardisation that still is on hold in this point.
The inhalation of radon (222Rn) decay products is the leading cause of lung cancer apart from tobacco smoking. Besides the permeation of radon from the subsoil through the basement as main source of radon in indoor air, also building materials have to be taken into consideration, especially at low air change rates in buildings. The Construction Products Regulation (EC, 2010) gives essential requirements for construction works regarding the release of dangerous substances such as toxic gases and radiation to which radon can be assigned. The recently adopted Basic Safety Standards Directive (EC, 2013), which has to be ratified by each European member state in between the next three years sets reference levels for indoor radon concentrations for the first time. In research project financed by the German Ministry for the Environment, Nature Conservation, Building and Nuclear Safety a practical, reliable and easily applicable test procedure for the determination of radon exhalation from building materials – based on ISO 16000-9 (ISO, 2006) and CEN/TS 16516 (CEN, 2013) – should be developed. In contrast to the static test procedure published by Richter et al. (2013), dynamically operated test chambers shall be foregrounded. First results of this study are presented, focused on the reliable measurement of radon background concentration and the selection of suitable radon test devices, representing the basic elements of the subsequent work.
In this paper, we introduce a nano aerial robot swarm for Indoor Air Quality (IAQ) monitoring applications such as occupational health and safety of (industrial) workplaces. The robotic swarm is composed of nano Unmanned Aerial Vehicles (UAVs), based on the Crazyflie 2.0 quadrocopter, and small lightweight Metal Oxide (MOX) gas sensors for measuring the Total Volatile Organic Compound (TVOC), which is a measure for IAQ. An indoor localization and positioning system is used to estimate the absolute 3D position of the swarm similar to GPS. A test scenario was built up to validate and optimize the swarm for the intended applications. Besides calibration of the IAQ sensors, we performed experiments to investigate the influence of the rotor downwash on the gas measurements at different altitudes and compared them with stationary measurements. Moreover, we did a first evaluation of the gas distribution mapping performance. Based on this novel IAQ monitoring concept, new algorithms in the field of Mobile Robot Olfaction (MRO) are planned to be developed exploiting the abilities of an aerial robotic swarm.
Formic acid (FA) treatment as measure against the ectoparasitic mite, Varroa destructor, which infests the western honey bee, Apis mellifera, is usually performed twice a year. Although the therapeutic index is very narrow and the success of FA-treatment is highly dependent on various external factors, little is known about the local FA concentrations occuring in the hive. In this study we examined whether a commercially available odour measuring device (“electronic nose”) is suitable for measurements of high FA concentrations, as present during treatment. As measuring systems, two different setups were prepared for detection of FA concentrations in gas mixtures: A polymethyl methacrylate (PMMA) box was used to investigate whether the electronic nose is able to distinguish between different FA concentrations and a two-storied Segeberger hive to test under realistic conditions during bee-keeping.
In both experimental systems, the signals from the same sensor components (sensor type no. 1, 6, 7, 8 and 9) showed an increased sensitivity towards the presence of FA in the gas mixture. Principle component analysis (PCA) and linear discriminant analysis (LDA) allowed for identification of specific patterns in the measurement signals and showed clear correlations between the signals and the present FA concentration. These results indicate that the introduced commercial multi gas sensor system is suitable for detection of high FA concentrations, and therefore could be a starting point developing a detection method of FA. The future aim is to successfully monitor the efficiency and effectiveness of this anti-varroa-treatment.
Compared to the intended EU reference level of 300 Bq m−3 for indoor radon concentrations, the contribution of building materials appears to be low. Considering the recommended limit of 100 Bq m−3 by WHO, their contribution is supposed to be relevant, especially at low air exchange rates. This study as part of a two-part research project investigated the suitability of direct low level 222Rn measurement under simulated indoor conditions with commercial radon monitors and dynamically operated emission test chambers. Active measuring devices based on ionisation or scintillation chambers with 1-σ uncertainties below 8.6% at 20 Bq m−3 were found to be best suitable for a practical test procedure for the determination of radon exhalation rates of building materials. For the measurement of such low concentrations, the knowledge of the accurate device background level is essential.