- nein (2)
In this work, we employed glow discharge optical emission spectrometry (GD-OES) depth profiling as a fast and semi-quantitative method to investigate the aluminum (Al) current collector degradation in commercial lithium cobalt oxide (LCO) pouch cells with no Al2O3 pretreatment. After battery aging, a heterogeneous deposit was found on the surface of the cathode. Gray hotspot areas within an extensive pale white region were formed. Consistent with energy dispersive X-ray (EDX) analysis of micro-cross sections milled via targeted focused ion beam (FIB), an Al-containing layer of approximately 3 µm can be observed using GD-OES. We attribute one main cause of this layer is the degradation of the Al current collector. The nonuniform growth of this layer was investigated by performing GD-OES depth profiling at different in-plane positions. We found that the gray area has a higher mass concentration of Al, probably in metallic form, whereas the white area was probably covered more homogeneously with Al2O3, resulting from the inhomogeneous distribution of the pitting positions on the current collector. Compared to FIB-EDX, GD-OES enables a faster and more convenient depth profile analysis, which allows the more productive characterization of lithium-ion batteries (LIBs), and consequently benefits the development of preferable battery materials.
Fast flow glow discharge mass spectrometry with a Grimm-type ion source providing a high sputter rate was used for the determination of major nonmetallic impurities in magnesium. The analytical signal was found to be strongly influenced by the electrical discharge parameters. For calibration by standard addition, synthetic standard samples were produced in two different ways—namely, by pressing and by sintering doped metal powders. The observed sensitivity of the calibration curves was shown to depend on the particle size of the powder. For the magnesium powders, the mass fractions of oxygen, nitrogen, boron, and silicon were determined to be about 0.01 kg·kg-1 (relative standard deviation approximately 10–20 %), 2,700 mg·kg-1, 150 mg·kg-1, and 300 mg·kg-1, respectively.
Mixed copper and titanium hydride powder was hot-pressed and characterized by Carrier Gas Hot Extraction, XRay Diffraction, Thermal Gravimetric Analysis coupled with Mass Spectrometry, and Scanning Electron Microscopy.
The hot-pressed and five conventional samples were applied for calibration of hydrogen in Glow Discharge Optical Emission and Mass Spectrometry. Up to the introduction of 15 ng/s hydrogen the Emission yield model is useful in Glow Discharge Optical Emission Spectrometry. A correlation between saturation and even reversal of the emission yield of the spectral lines H121, H486 and H656 and low sputtering rates was found. Hydrogen effects exist for the spectral lines of Cu(II) 219 and Ti(I) 399. In Glow Discharge Mass Spectrometry, a linear dependency of the 1H ion current on the sputtered mass per time exists over the total range of hydrogen content investigated. Hydrogen effects also exist for the sensitivity of 48Ti and 63Cu. The sputtering rate of two-phase materials depends linearly on the sputtered mass per time of one phase, which allows the sputtering rate of two-phase materials with known composition to be predicted.
Analytical glow discharges with optical (GD-OES) and mass spectrometric (GD-MS) detection are able to obtain depth resolved information about the light elements hydrogen, carbon, nitrogen and oxygen in solid samples, where most of the other analytical techniques fail. However, the interpretation or even quantification of the measured signals is still very challenging. Problems arise due to physical effects (plasma processes such as the ‘Hydrogen effect’, the Doppler effect, self absorption or diffusion of hydrogen in the sample during sputtering) chemical effects(e.g. formation of compounds with argon or the matrix, poisoning of the sample or gettering) as well as instrumental difficulties (e.g. of the sensitivity, calibration and vacuum quality)..
The GD techniques are direct solid sampling methods and require reference materials for calibration. Unfortunately the list of available certified reference materials (CRM) suited for calibration of light elements in different matrix is relatively short Therefore, sintered materials doped with the analytes H2, O2 and N2 were produced at IFW Dresden and applied as calibration standards for hydrogen, oxygen and nitrogen. Due to the high analyte concentration added, it is very likely that the real concentration agree well with the added amount of light elements in the corresponding phases. The validation of the determination of the light element concentration in the sintered samples was possible in some cases only due to the lack of suitable techniques. This fact proves the need for the development of a reliable quantification of light elements by GDS.
A systematic dependence of the sputtering rate on the composition was found and can be explained by basic principles.
Using mixtures of TiH2 and ZrH2 with Cu the ratio of hydrogen and Cu lines has a good correlation with the corresponding concentration ratio. The hydrogen emission yield however decreases over 0.3 m% hydrogen and finally the hydrogen intensity may even decrease. This behaviour can be explained by a very similar quenching of the hydrogen and copper intensity caused by the hydrogen effect. First experiments with GD-MS show no saturation of the hydrogen ion current and thus confirm the quenching of the emission yield in GD-OES.
Sintered material for the oxygen calibration (Al2O3, CuO, Cu2O and MgO mixed with Cu, Al and Mg) confirmed the blue line shift effect at O I 130.22 nm, first time reported by Köster 2009 [1]. The effect is more pronounced at Mg than in Al and Cu, which due to line interference leads to a matrix dependent EY. This effect is negligible at O I 777.19 nm and the EY is matrix independent. Using GD-MS first promising results for the calibration of oxygen with these sintered samples could be obtained, when the sputtering rate was included in the evaluation.
More recently also sintered material for nitrogen calibration (AlN mixed with Al and Si3N4 mixed with Cu) was produced and points to a matrix independent emission yield of nitrogen
The analysis of thin layers of thickness 100 nm has become a new field of application for glow discharge optical emission spectroscopy (GDOES). In this paper an overview is given of the experiences and possibilities gained by the authors in later years at their research, development and application of GDOES.
During GDOES analysis of a multilayer system the depth resolution was determined using the inverse maximal slope method. Under optimized discharge conditions a depth resolution of 25 nm at 100 nm depth was achieved. The gas flow in a Grimm-type source for glow discharge mass spectrometry (GDMS) was simulated and a correlation between calculated pressure and crater shape was found. Cleanness of the sample and source turned out to be essential for a fast stabilization time and reduction of the influence of light elements and molecules. Thereby, a 10 nm layer at the top surface of a sample could be quantified. Apart from the influence of density, the reflectivity of the sample surface is discussed. It is shown that a high sample reflectivity can cause up to 100% more light to be measured by the spectrometer.
Depth profiling of electrically non-conductive layered samples by RF-GDOES and HFM plasma SNMS
(2001)
The work is intended to compare the capabilities of two similar depth profiling techniques to analyse electrically non-conductive samples. In order to get a better evaluation of the depth resolution, various multilayer sandwiches, such as SiO2/TiO2 and Si3N4/SiO2 deposited on glass substrates have been investigated. Optimised depth profiles are presented for both methods, glow discharge optical emission spectrometry (GDOES) and radiofrequency mode (known as HFM in the SNMS literature) of plasma secondary neutral mass spectrometry (SNMS). The optimisation procedure, necessary to get the best set of plasma parameters, which result in the optimal depth resolution, is also described for one selected sample. Additionally, sputtering crater profilometry was carried out in order to check out the flatness of the sputtered crater. The influence of the thickness of the sample substrate on the sputtering rate is discussed. Finally, advantages and disadvantages of the use of these two depth profiling methods, especially for the non-conductive samples, are concluded from this comparative study. Time-of-flight secondary ion mass spectrometry (ToF-SIMS) analysis of a cross-sectioned sample was carried out in order to get supplementary information.
In order to gain an insight into the numerous effects caused by the addition of hydrogen to an argon glow discharge, comparison experiments have been made with neon as carrier gas. In some cases the effects are diminished or even disappear. Using various bulk samples, such as copper, steel and titanium, sputtered in a neon glow discharge, the intensities of the analytical lines are affected by the presence of hydrogen in different ways from argon; the dependent parameter (the discharge current in this work) and the sputtering rate vary less than in argon. The crater shape and roughness are also affected and these effects are discussed qualitatively. Probably the most important spectral feature caused by hydrogen in the case of a discharge in argon is the emission of a continuous background. This does not appear in neon under similar discharge conditions and only weakly at high hydrogen concentrations. This supports the suggestion, made in previous work, that an effective quenching process of the argon metastables (11.55 and 11.72 eV) is Penning excitation of the hydrogen molecules, and subsequent decay to a repulsive state with emission of the continuum; in neon the energy match does not occur. It was found with neon, as with argon, that similar features occur as when hydrogen is introduced in different ways into the glow discharge: as a molecular gas contamination or as a constituent of the sample. Glow discharge mass spectrometry (GD-MS) experiments carried out with both argon and neon support the results obtained by optical emission spectrometry (OES) and provide further relevant information.