Filtern
Erscheinungsjahr
Dokumenttyp
Sprache
- Englisch (153)
Referierte Publikation
- ja (153) (entfernen)
Schlagworte
- Nanoparticles (29)
- EDX (23)
- SEM (21)
- EDS (12)
- Electron microscopy (11)
- XRF (10)
- EPMA (8)
- CCQM (7)
- Titanium dioxide (7)
- ToF-SIMS (6)
- Transmission (6)
- XPS (6)
- Elemental composition (5)
- Modelling (5)
- Sample preparation (5)
- T-SEM (5)
- TiO2 (5)
- High-resolution (4)
- Nanomaterials (4)
- Shape (4)
- Size (4)
- Spectroscopic ellipsometry (4)
- Thin films (4)
- WDX (4)
- X-ray scattering (4)
- X-rays (4)
- AES (3)
- Bisphenol A (3)
- CIGS (3)
- CRM (3)
- Calibration (3)
- Characterization (3)
- ED-EPMA (3)
- Image analysis (3)
- Interlaboratory comparison (3)
- Key comparison (3)
- Nano (3)
- Nanomaterial (3)
- Nanoparticle (3)
- Nanotechnology (3)
- Particle size (3)
- Porosity (3)
- Quantification (3)
- Quantum dots (3)
- Reference material (3)
- SEM/EDX (3)
- Size distribution (3)
- Standardization (3)
- TEM (3)
- X-ray optics (3)
- X-ray spectroscopy (3)
- X-ray tube (3)
- (mu-)XRF (2)
- Acceptance area (2)
- Advanced materials (2)
- Atomic force microscopy (2)
- Auger Electron Spectroscopy (2)
- Characterisation (2)
- Composites (2)
- Concentration (2)
- Decision support (2)
- Energy dispersive X-ray spectroscopy (EDX) (2)
- Energy-dispersive X-ray spectrometer (EDS) (2)
- FWHM (2)
- Fenton (2)
- Film thickness (2)
- Focal distance (2)
- GDS (2)
- Geometrical collection efficiency (2)
- Imaging (2)
- Ionic liquids (2)
- K-values (2)
- Katalysator (2)
- Micro-focus-XRF (2)
- Micropollutants (2)
- Monte-Carlo simulation (2)
- Morphology (2)
- Multi-sample analysis (2)
- Nanomaterial classification (2)
- Parallelising mode (2)
- Particle (2)
- Performance check (2)
- Photooxidation (2)
- Pilot study (2)
- Polycapillary X-ray optics (2)
- Porous materials (2)
- Quantum yield (2)
- Regulation (2)
- Roughness (2)
- SAXS (2)
- SEM/EDS (2)
- STRATAGem (2)
- Scanning electron microscope (SEM) (2)
- Scanning electron microscopy (SEM) (2)
- Semi-lens (2)
- SiO2 (2)
- Size measurement (2)
- Spectrometer efficiency (2)
- Standardisation (2)
- Standards (2)
- Surface analysis (2)
- Surface chemical analysis (2)
- Surface functionalization (2)
- Test material (2)
- Thin film (2)
- VAMAS (2)
- WD-EPMA (2)
- Wastewater (2)
- X-ray photoelectron spectroscopy (2)
- X-ray tube spectrum (2)
- ACEnano (1)
- AFM (1)
- Absolute X-ray spectrum (1)
- Absorption spectrometry (1)
- Abwasser (1)
- Advanced material (1)
- AgInS (1)
- Agglomeration/aggregation (1)
- Alloy films (1)
- Amorphous phases (1)
- Amperometry (1)
- Analytical SEM (1)
- Anti-corrosion (1)
- Anti-corrosion coatings (1)
- Apatite (1)
- Aqueous synthesis (1)
- Artificial intelligence (1)
- Auger Electron Spectroscopy (AES) (1)
- Austenitic phase (1)
- Automated image analysis (1)
- Automation (1)
- BAM-L200 (1)
- Bearing steel (1)
- Benchmarking (1)
- Biofilms (1)
- Biomedical application (1)
- Bipyramid (1)
- Bisphenol A degradation (1)
- Blue pigment (1)
- Boehmite (1)
- Boehmite nanoparticles (1)
- Brunauer-Emmett-Teller (1)
- CEN (1)
- Caenorhabdtis elegans (1)
- Calcium monofluoride (1)
- Calcium titanium phosphate (1)
- Calibrated SEM/EDS (1)
- Carbamazepine (1)
- Catalysis (1)
- Catalytic wet peroxide oxidation (1)
- Cationic photocuring (1)
- Cerium oxide (1)
- Certification (1)
- Certified reference material (1)
- Certified reference nanomaterials (1)
- Characterisation techniques (1)
- Characterization of catalysts (1)
- Charge (1)
- Chemistry (1)
- Classification (1)
- Coated/Layered Reference Materials (1)
- Coating (1)
- Coatings (1)
- Coimbra (1)
- Complementary methodology and metrology (1)
- Complex-shape (1)
- Composition (1)
- Compton scattering (1)
- Controlled morphology (1)
- Controlled periodic illumination (1)
- Controlled-shape (1)
- Core-shell nanoparticles (1)
- Core-shell particles (1)
- Core–shell particles (1)
- Correlative analysis (1)
- Crater shape (1)
- Cross-sectioning (1)
- Crosslinking density (1)
- Crystal growth (1)
- Crystallinity (1)
- Cu-Au alloy (1)
- Cyclic voltammetry (1)
- Cycloaliphatic epoxy oligosiloxane (1)
- Cyclometalated iridium (III) complexes (1)
- Cytotoxicity (1)
- DSSC (1)
- Data correlation (1)
- Data readiness level (1)
- Definition (1)
- Density (1)
- Depth profiling (1)
- Depth resolution (1)
- Detection efficiency (1)
- Detection limits (1)
- Detector efficiency (1)
- Dodecanethiol (1)
- Duplex stainless steel (1)
- EC nanomaterial definition (1)
- EDS detector (1)
- EDS performance test (1)
- EDS-TM001 (1)
- EDS-TM002 (1)
- ESR (1)
- Effective area (1)
- Effective solid angle (1)
- Electrocatalysis (1)
- Electrochemical catalysts (1)
- Electrochemistry (1)
- Electrolysis (1)
- Electron probe microanalysis (1)
- Electrospary (1)
- Electrospun nanocomposite fiber (1)
- Emission spectroscopy (1)
- Endocrine disruptor (1)
- Energy dispersive (1)
- Energy dispersive X-ray spectrometry (1)
- Energy dispersive X-ray spectroscopy (1)
- Energy dispersive electron probe microanalysis (ED-EPMA) (1)
- Energy resolution (1)
- Energy-dispersive X-ray spectroscopy (EDX, XEDS) (1)
- Environment (1)
- Epoxy (1)
- Epoxy conversion degree (1)
- Epoxy nanocomposites (1)
- European Centre (1)
- Expert system (1)
- F- doping (1)
- FAIRification (1)
- Fe-Ni (1)
- Fe-Ni alloy (1)
- Fe-Ni alloy film (1)
- Fe-based highly active ionic liquids (1)
- FeNi (1)
- Fenton oxidation (1)
- Ferritic phase (1)
- Films (1)
- Firing temperature (1)
- Five iron oxalate core–shell magnetite nanoparticles catalysts are evaluated as magnetic heterogeneous (1)
- Fluoride (1)
- Focused ion beam tomography (1)
- Functionalized graphene (1)
- GD-OES (1)
- GDMS (1)
- GDOES (1)
- Genotoxic and oxidative damage (1)
- Governance (1)
- Graphite furnace (1)
- Grimm type glow discharge (1)
- HFM plasma SNMS (1)
- HR-CS-MAS (1)
- Hard-energy X-ray photoelectron spectroscopy (1)
- High-resolution scanning electron microscope (SEM) (1)
- High-resolution transmission in SEM (TSEM) (1)
- Hollow cathode (1)
- Homogeneity (1)
- Hybrid metrology (1)
- Hybrid metrology measurement (1)
- Hydrogen (1)
- Hydrogen evolution reaction (1)
- Hydrogen photoproduction (1)
- ISO (1)
- ISO 15632 (1)
- Identification (1)
- Image segmentation (1)
- Imaging surface analysis (1)
- Imaging surface chemical analysis (1)
- Immunoassay (1)
- In-situ SAXS/WAXS (1)
- Infrared nano AFM (1)
- Inter-laboratory comparison (1)
- Intermediate phases (1)
- Intermodulation (1)
- Intermodulation AFM (1)
- Interphase (1)
- Intrinsic OER activity (1)
- Iron oxide (1)
- K-rich Birnessite (K0.45MnO2) (1)
- Kramers background (1)
- Large area SDD (1)
- Large-area EDS (1)
- Laser ablation in liquid (1)
- Lateral resolution (1)
- Layer-by-layer deposition (1)
- Lifetime analysis (1)
- Ligand exchange (1)
- Limits of detection (1)
- Line scan (1)
- Lisbon (1)
- Low energy (1)
- Lubricated contact (1)
- Luminescent lifetime (1)
- Machine learning (1)
- Magic-sized cluster (1)
- Magnetic coreshell nanocatalysts (1)
- Magnetic nanocatalyst (1)
- Magnetische Nanopartikel (1)
- Magnetpartikel (1)
- Manufacturing (1)
- Mapping (1)
- Mass coverage (1)
- Mass deposition (1)
- Measurement uncertainty (1)
- Mechanical properties (1)
- Mesoporosity (1)
- Mesoporous iridium oxide films (1)
- Method development (1)
- Metrological traceability (1)
- Metrology (1)
- Micro- and nanocapsules (1)
- Micro-Raman imaging (1)
- Micro-XRF (1)
- Microanalysis (1)
- Microbially influenced corrosion (MIC) (1)
- Microcapsules (1)
- Microfocus x-ray source (1)
- Microwave-assisted synthesis (1)
- Mitigation (1)
- Mixed metal oxide (1)
- Monochromatic excitation (1)
- Multilayer (1)
- Nano-safety (1)
- NanoValid (1)
- Nanocapsules (1)
- Nanocatalysts (1)
- Nanocomposite (1)
- Nanocomposites (1)
- Nanomaterial analysis (1)
- Nanomaterial categorisation (1)
- Nanomaterial definition (1)
- Nanomaterial legislation (1)
- Nanomaterial regulation (1)
- Nanomechanical charecteisation (1)
- Nanomechanical properties (1)
- Nanometrology (1)
- Nanoparticle concentration (1)
- Nanoparticle structure (1)
- Nanopowder (1)
- Nanosafety (1)
- Nanoscale EDX analysis (1)
- Nanoscale T-SEM (1)
- Nanosheets (1)
- Nanotoxicology (1)
- Neural networks (1)
- Nitrides (1)
- Non-classical crystallization theory (1)
- Non-conductive layered samples (1)
- Non-destructive ambient analysis (1)
- Number-weighted median size (1)
- OECD (1)
- Ochratoxin A (1)
- One-pot synthesis (1)
- Optically active surfaces (1)
- Oxygen evolution reaction (1)
- Oxygen evolution reaction (OER) (1)
- Particle morphology (1)
- Particle size analysis (1)
- Particle size and shape distribution (1)
- Particle size distribution (1)
- Peak-to-background (1)
- Peak-to-noise (1)
- Perfluorooctanoic Acid (PFOA) (1)
- Phosphates (1)
- Photo-Fenton oxidation (1)
- Photocatalysis (1)
- Photodegradation (1)
- Photoelectrochemistry (1)
- Photon generation yield (1)
- Photoreforming (1)
- Physicochemical characterization (1)
- Platinum (1)
- Polarisation (1)
- Polyethylene glycol (1)
- Porosimetry (1)
- Portuguese glazed ceramics (1)
- Portuguese polychrome glazed pottery (1)
- Pphosphates (1)
- Quality assurance (1)
- Raman spectroscopy (1)
- Rayleigh scattering (1)
- Reactive azo dye degradation (1)
- Real-time infrared spectroscopy (1)
- Reference materials (1)
- Reference-free XRF (1)
- Removal (1)
- Reproducibility (1)
- Rheology (1)
- Risk asessment (1)
- RoHS (1)
- Round Robin (1)
- Ru dye sensitizer (1)
- SIMS (1)
- STEM-in-SEM (1)
- STRATAGEM (1)
- STXM (1)
- Sabatier (1)
- Scanning and transmission electron microscopies (1)
- Scanning electron microscopy (1)
- Scanning mobility particle size spectrometers (1)
- Scanning probe microscopy (1)
- Scattering (1)
- Secondary ion mass spectrometry (1)
- Semiconductor nanocrystals (1)
- Sensitivity (1)
- Sensitized magnetic nanocatalysts (1)
- Setup (1)
- Shape distribution (1)
- Shape-controlled nanoparticles (1)
- Shape-engineered (1)
- Sharpness (1)
- SiGe (1)
- SiO2 nano-aerosol size distribution (1)
- Side-window X-ray tube (1)
- Single nanoparticles (1)
- Singlet oxygen (1)
- Singulettsauerstoff (1)
- Size measurements (1)
- Small-angle X-ray scattering (1)
- Software (1)
- Sol-gel processing (1)
- Solar Cell (1)
- Solar concentrator (1)
- Solar energy (1)
- Solid angle (1)
- Solubility (1)
- Sonochemical synthesis (1)
- Spectral background (1)
- Spectrometer calibration (1)
- Spherical nanoparticles (1)
- Stability (1)
- Standard operation procedures (1)
- Standardless analysis (1)
- Stratagem (1)
- Strength (1)
- Strontium titanate (1)
- Struvite (1)
- Surface (1)
- Synthesis (1)
- TEM grid (1)
- TKD (1)
- TOF-SIMS mappings (1)
- TRL (1)
- TSEM (1)
- Ternary alloys (1)
- Test materials (1)
- Thermal analysis (1)
- Thermoplastics (1)
- Thermosets (1)
- Thickness (1)
- Thin film metrology (1)
- Thin mesoporous films (1)
- Thin-layer analysis (1)
- Thiols (1)
- Threshold (1)
- TiO2 films (1)
- Tiered (1)
- Titania (1)
- Titanium oxide (1)
- Trace elements (1)
- Traceability (1)
- Traceable nanoparticle size measurements; (1)
- Transition metal (1)
- Transition metals (1)
- Transmission Kikuchi diffraction (1)
- Transmission electron microscopy (1)
- Transmission in SEM (1)
- Transmission mode (1)
- Transmission scanning electron microscopy/microscope (TSEM, T-SEM, STEM) (1)
- Transmission-SEM (1)
- Trends (1)
- Uncertainty (1)
- VSSA (1)
- Volcano plot (1)
- Volume specific surface area (1)
- WDS (1)
- Water treatment (1)
- Wear particle analysis (1)
- X-ray Fluorescence (1)
- X-ray detectors (1)
- X-ray emission yield (1)
- X-ray fluorescence (1)
- X-ray fluorescence analysis (1)
- X-ray production yield (1)
- X-ray spectrometer (1)
- X-ray tube spectra (1)
- XANES (1)
- XPEEM (1)
- Xerogel (1)
- Yellow pigment (1)
- Zinc oxide (1)
- Zirconium (1)
- ZnSe (1)
- analytical service (1)
- k-values (1)
- layered system (1)
- mu-XRF (1)
- muXRF (1)
- rf system (1)
- rf-Glow discharge (1)
- silica nanoparticles (1)
- surface and in-depth inspection (1)
- titania nanoparticles (1)
- transmission mode (1)
Organisationseinheit der BAM
- 6 Materialchemie (59)
- 6.1 Oberflächen- und Dünnschichtanalyse (59)
- 1 Analytische Chemie; Referenzmaterialien (15)
- 1.2 Biophotonik (6)
- 1.8 Umweltanalytik (5)
- 6.3 Strukturanalytik (5)
- 6.6 Physik und chemische Analytik der Polymere (5)
- 5 Werkstofftechnik (4)
- P Präsident (4)
- P.0 Präsident und andere (4)
Paper des Monats
- ja (5)
Low-energy BO and BO2 emission from H2BO3 sputtered in a low-pressure high-frequency SNMS plasma
(1999)
Background corrected secondary neutral energy spectra derived from Cu powder pellets with H3BO3, MgO, Al2O3, TiO2, Y2O3 and ZrO2, show energy distributions being more or less typical for collision cascades in the cases of the metal ions M+, of O+ at energies >5 eV above the ion generation potential, and of the molecules Cu2+, AlO+, TiO+, YO+ and ZrO+, whereas the larger parts of the energy distributions of BO+and BO2+exhibit a similar shape as the Ar+plasma gas ions. From this, and from the background of the low decomposition and melting temperatures of H3BO3 and B2O3, respectively, we conclude that the detected BO and BO2 molecules have been emitted with thermal energies in processes implying lower energies than collision cascades. Evidence was found that the same holds for HBO2 and H2BO2. In order to obtain relative correction factors for MO+ molecular ion intensities, electron impact ionization cross sections have been calculated for the light MO molecules using the binary-encounter Bethe (BEB) formula, and for the respective metal M atoms by means of the semiempirical Lotz formula. For the heavy MO molecules YO and ZrO, cross sections have been estimated using the Thomson formula. The comparison of corrected relative MO/M and M/Cu intensities yields evidence that thermal (H)BOx emission amounts to the same order of magnitude as B emission from collision cascades, and that this situation is comparable to the high yield of MO molecules emitted in collision cascades from oxides with high M masses. Since the normal energy window of an HF-plasma secondary neutral mass spectrometer does not accept particles with originally thermal energies, it is concluded that these findings are relevant for quantification.
Clear evidence of the effects caused by hydrogen, introduced in different forms in an analytical glow discharge source (GDS) operated with argon, is presented for the different matrix elements copper, stainless steel, titanium, aluminium and silicon. When hydrogen is present even in small quantities in argon, not only are there significant changes in the emission line intensities of most elements (analyte and plasma species), but also new spectral features, such as emission bands of new compounds (hydrides of sputtered sample constituents) and a continuous background in the range ~220440 nm. Moreover, the discharge current (the dependent parameter in our experiments) decreases with increasing hydrogen concentration. Different modes of hydrogen introduction, externally in gaseous form or sputtered as a sample constituent, cause very similar effects in terms of discharge current, line intensity (of analyte and plasma gas) and emission continua, which implies similar changes in the discharge processes in the two cases. The excitation of the hydrogen continuum appears to quench the population of the argon metastables (11.55 and 11.72 eV) and, consequently, other elementary processes in the plasma in which the argon metastables take part, but to a different extent for each analyte.
The influence of hydrogen contained in a sample or otherwise introduced into a glow discharge source (GDS) is here extensively experimentally presented for the case of copper as a sample by means of the addition of small quantities of molecular hydrogen (<1% relative partial pressure) to the argon carrier gas. The progressive addition of molecular hydrogen causes different intensity changes particular to the individual lines of different species such as atomic (Cu I) and ionic (Cu II) copper, and also atomic (Ar I) and ionic (Ar II) argon. Some interesting features of the emission spectrum of hydrogen such as its line, band and even continuum spectrum are observed. It was also found that the depth resolution becomes worse even at very low concentrations of hydrogen.
Depth profiling of electrically non-conductive layered samples by RF-GDOES and HFM plasma SNMS
(2001)
The work is intended to compare the capabilities of two similar depth profiling techniques to analyse electrically non-conductive samples. In order to get a better evaluation of the depth resolution, various multilayer sandwiches, such as SiO2/TiO2 and Si3N4/SiO2 deposited on glass substrates have been investigated. Optimised depth profiles are presented for both methods, glow discharge optical emission spectrometry (GDOES) and radiofrequency mode (known as HFM in the SNMS literature) of plasma secondary neutral mass spectrometry (SNMS). The optimisation procedure, necessary to get the best set of plasma parameters, which result in the optimal depth resolution, is also described for one selected sample. Additionally, sputtering crater profilometry was carried out in order to check out the flatness of the sputtered crater. The influence of the thickness of the sample substrate on the sputtering rate is discussed. Finally, advantages and disadvantages of the use of these two depth profiling methods, especially for the non-conductive samples, are concluded from this comparative study. Time-of-flight secondary ion mass spectrometry (ToF-SIMS) analysis of a cross-sectioned sample was carried out in order to get supplementary information.
In order to gain an insight into the numerous effects caused by the addition of hydrogen to an argon glow discharge, comparison experiments have been made with neon as carrier gas. In some cases the effects are diminished or even disappear. Using various bulk samples, such as copper, steel and titanium, sputtered in a neon glow discharge, the intensities of the analytical lines are affected by the presence of hydrogen in different ways from argon; the dependent parameter (the discharge current in this work) and the sputtering rate vary less than in argon. The crater shape and roughness are also affected and these effects are discussed qualitatively. Probably the most important spectral feature caused by hydrogen in the case of a discharge in argon is the emission of a continuous background. This does not appear in neon under similar discharge conditions and only weakly at high hydrogen concentrations. This supports the suggestion, made in previous work, that an effective quenching process of the argon metastables (11.55 and 11.72 eV) is Penning excitation of the hydrogen molecules, and subsequent decay to a repulsive state with emission of the continuum; in neon the energy match does not occur. It was found with neon, as with argon, that similar features occur as when hydrogen is introduced in different ways into the glow discharge: as a molecular gas contamination or as a constituent of the sample. Glow discharge mass spectrometry (GD-MS) experiments carried out with both argon and neon support the results obtained by optical emission spectrometry (OES) and provide further relevant information.
Glow discharge optical emission spectroscopy (GD-OES) is briefly reviewed, with particular reference to topics relevant to the application field of near surface and thin film analysis. The special needs and requirements for thin film analysis, in contrast to coating and bulk analysis, are pointed out. A task list is developed which shows the requirements of further developments to the technique and the fundamentals. The state-of-the-art is presented in measurement technique, GD source control and design, the effect of traces of molecular gases, correction and quantification procedures, contributions of modelling and, finally, reference materials for thin film analysis.
The analysis of thin layers of thickness 100 nm has become a new field of application for glow discharge optical emission spectroscopy (GDOES). In this paper an overview is given of the experiences and possibilities gained by the authors in later years at their research, development and application of GDOES.
During GDOES analysis of a multilayer system the depth resolution was determined using the inverse maximal slope method. Under optimized discharge conditions a depth resolution of 25 nm at 100 nm depth was achieved. The gas flow in a Grimm-type source for glow discharge mass spectrometry (GDMS) was simulated and a correlation between calculated pressure and crater shape was found. Cleanness of the sample and source turned out to be essential for a fast stabilization time and reduction of the influence of light elements and molecules. Thereby, a 10 nm layer at the top surface of a sample could be quantified. Apart from the influence of density, the reflectivity of the sample surface is discussed. It is shown that a high sample reflectivity can cause up to 100% more light to be measured by the spectrometer.
Scanning electron microscopes are usually equipped with energy-dispersive X-ray detectors for electron probe microanalysis. This widespread analytical method allows investigators to determine the elemental composition of specimens with a spatial resolution of about 1 µm. However, owing to the electron-specimen interaction, the emitted spectra reveal, in addition to characteristic lines, also a high level of continuous bremsstrahlung background. As a result, elements with low concentrations cannot be identified. The minimum detection limit can be diminished by two orders of magnitude if the characteristic lines are excited as fluorescence by an additional x-ray source. In this case, the emergence of bremsstrahlung is considerably reduced. Combining a high-brilliance microfocus x-ray tube with efficient polycapillary optics enables one to realize an experimental arrangement for performing local fluorescence analysis at the same point where the electron beam hits the sample. The polycapillary optics under consideration focuses the emitted x-radiation onto focal spots between 30 and 100 µm in diameter. Count rates of several thousands cps have been achieved. Elemental maps have been obtained by means of the motorized specimen stage of the microscope. Copyright © 2005 John Wiley & Sons, Ltd.