- EDX (8)
- CCQM (7)
- EPMA (4)
- Nanoparticles (4)
- XPS (4)
- AES (3)
- CIGS (3)
- Key comparison (3)
- Nanotechnology (3)
- T-SEM (3)
Organisationseinheit der BAM
Auger electron spectroscopy
(2020)
An introduction in the application of Auger Electron Spectroscopy to surface chemical analysis of nanoparticles is given. Auger Electron Spectroscopy is a mature method in the field of surface chemical analysis. The chapter addresses the physical basis of the method, the principal design of recent instruments together with modes of operation and options for the presentation of spectra, as well as different approaches for qualitative (including identification of chemical species) and quantitative surface analysis of elements. An application paragraph on surface chemical analysis of nanoparticles by AES or SAM introduces the different measurement approaches and sample preparation strategies applied by analysts. The analysis of nanoparticle ensembles, the so-called selected point analysis where a narrow primary electron beam is centered on an individual nanoparticle, and chemical mapping of individual nanoparticles (or a line scan across) are addressed. Existing literature is reviewed and informative case studies presented. Limitations and pitfalls in the application of AES in surface chemical analysis of nanoparticles are also addressed.
The coming years are expected to bring rapid changes in the nanotechnology regulatory landscape, with the establishment of a new framework for nano-risk governance, in silico approaches for characterisation and Risk assessment of nanomaterials, and novel procedures for the early identification and management of nanomaterial risks. In this context, Safe(r)-by-Design (SbD) emerges as a powerful preventive approach to support the development of safe and sustainable (SSbD) nanotechnology-based products and processes throughout the life cycle. This paper summarises the work undertaken to develop a blueprint for the deployment and operation of a permanent European Centre of collaborating laboratories and research organisations supporting safe Innovation in nanotechnologies. The proposed entity, referred to as “the Centre”, will establish a ‘one-stop shop’ for nanosafety-related services and a central contact point for addressing stakeholder questions about nanosafety. Its operation will rely on significant business, legal and market knowledge, as well as other tools developed and acquired through the EU-funded EC4SafeNano project and subsequent ongoing activities. The proposed blueprint adopts a demand-driven service update scheme to allow the necessary vigilance and flexibility to identify opportunities and adjust its activities and services in the rapidly evolving regulatory and nano risk governance landscape.
The proposed Centre will play a major role as a conduit to transfer scientific knowledge between the Research and commercial laboratories or consultants able to provide high quality nanosafety services, and the end-users of such services (e.g., industry, SMEs, consultancy firms, and regulatory authorities). The Centre will harmonise service provision, and bring novel risk assessment and management approaches, e.g. in silico methodologies, closer to practice, notably through SbD/SSbD, and decisively support safe and sustainable innovation of industrial production in the nanotechnology industry according to the European Chemicals Strategy for Sustainability.
A pilot study for the quantitative surface analysis of multi-element alloy films has been performed by the Surface Analysis Working Group (SAWG) of the Consultative Committee for Amount of Substance (CCQM). The aim of this pilot study is to ensure the equivalency in the measurement capability of national metrology institutes for the quantification of multi-element alloy films. A Cu(In,Ga)Se2 (CIGS) film with non-uniform depth distribution was chosen as a representative multi-element alloy film. The atomic fractions of the reference and the test CIGS films were certified by isotope dilution - inductively coupled plasma/mass spectrometry. A total number counting (TNC) method was used as a method to determine the signal intensities of the constituent elements, which are compared with their certified atomic fractions. The atomic fractions of the CIGS films were measured by various methods, such as Secondary Ion Mass Spectrometry (SIMS), Auger Electron Spectroscopy (AES), X-ray Photoelectron Spectroscopy (XPS), X-Ray Fluorescence (XRF) analysis and Electron Probe Micro Analysis (EPMA) with Energy Dispersive X-ray Spectrometry (EDX). Fifteen laboratories from eight National Metrology Institutes (NMIs), one Designated Institute (DI) and six non-NMIs participated in this pilot study. Although the average atomic fractions of 18 data sets showed rather poor relative standard deviations of about 5.5 % to 6.8 %, they were greatly improved to about 1.5 % to 2.2 % by excluding 5 strongly deviating data sets from the average atomic fractions. In this pilot study, the average expanded uncertainties of SIMS, XPS, AES, XRF and EPMA were 3.84%, 3.68%, 3.81%, 2.88% and 2.90%, respectively. These values are much better than those in the key comparison K-67 for composition of a Fe-Ni alloy film. As a result, the quantification of CIGS films using the TNC method was found to be a good candidate as a subject for a CCQM key comparison.
Characterization of Pd-Ni-Co alloy thin films by ED-EPMA with application of the STRATAGEM software
(2012)
Ternary thin film alloys based on Pd, Ni and Co on silicon wafers have been characterized in order to determine elemental composition and thickness. A broad variety of alloy compositions was obtained on one and the same substrate by magnetron dc-co-sputter deposition. Energy-dispersive electron probe X-ray microanalysis of these 'multi' alloy composition samples is performed in a non-destructive, precise and, if optimized, also in a time-saving way. The local thickness of the layers under study was in between 50 nm and 250 nm. Pure element bulk materials have been employed as reference specimens. The results attained in this study are compared to those obtained by other analytical methods as Auger electron spectroscopy and X-ray photo electron spectroscopy.
Conclusions and perspectives
(2020)
This chapter briefly summarizes the methods selected within this book for the characterization of nanoparticles with regard to commonly accessible properties: nanoparticle size and size distribution, shape, surface area, surface charge, aggregation state, structure, chemical composition, surface chemistry, and nanoparticle number concentration. Current progress of measurement and analysis, as far as possible according to standard operation procedures, has been the focus of this work. A number of new and less commonly used methods have not been covered, and we outline some of these in this chapter. Future challenges such as automated measurement and analysis, read-across approaches for the prediction of properties, knowledge of measurement uncertainties, the need for certified reference materials, and the necessity to complement measurements methods to obtain more reliable results are covered, and the unmet measurement requirements for real-world nanoparticles are described.
This is a corrigendum to the original article "Determining the thickness and completeness of the shell of polymer core-shell nanoparticles by X-ray photoelectron spectroscopy, secondary ion mass spectrometry, and transmission scanning electron microscopy" that was published in "The journal of physical chemistry C", vol. 123 (2019), no. 49 pp. 29765-29775.
Depth profiling of electrically non-conductive layered samples by RF-GDOES and HFM plasma SNMS
(2001)
The work is intended to compare the capabilities of two similar depth profiling techniques to analyse electrically non-conductive samples. In order to get a better evaluation of the depth resolution, various multilayer sandwiches, such as SiO2/TiO2 and Si3N4/SiO2 deposited on glass substrates have been investigated. Optimised depth profiles are presented for both methods, glow discharge optical emission spectrometry (GDOES) and radiofrequency mode (known as HFM in the SNMS literature) of plasma secondary neutral mass spectrometry (SNMS). The optimisation procedure, necessary to get the best set of plasma parameters, which result in the optimal depth resolution, is also described for one selected sample. Additionally, sputtering crater profilometry was carried out in order to check out the flatness of the sputtered crater. The influence of the thickness of the sample substrate on the sputtering rate is discussed. Finally, advantages and disadvantages of the use of these two depth profiling methods, especially for the non-conductive samples, are concluded from this comparative study. Time-of-flight secondary ion mass spectrometry (ToF-SIMS) analysis of a cross-sectioned sample was carried out in order to get supplementary information.
An inter-laboratory comparison organized as a pilot study (PS) has been performed under the umbrella of the Consultative Committee for Amount of Substance – Metrology in Chemistry (CCQM) / Surface Analysis Working Group (SAWG) with the objective to compare k-values measured with Electron Probe X-ray Microanalysis (EPMA) for copper-gold alloys. The k-value, defined as the ratio of the Xray photon intensity of an X-ray characteristic line of the unknown sample to the corresponding one in the reference material, is a rough estimate of the mass fraction of the respective element. Basically, the mass fractions can be calculated from the k-values after applying a matrix correction procedure, which includes empirical approaches, so that traceability gets lost. Due to its physical, measurable nature, the k-value has been selected in the present PS as the primary measurand. The mass fraction has been set as the secondary (derived) measurand. Both EDX and WDX have been employed. The WDX results and the overall comparability between the k-values obtained by EDX and WDX are still in progress.
Core–shell nanoparticles (CSNPs) have become indispensable in various industrial applications. However, their real internal structure usually deviates from an ideal core–shell structure. To control how the particles perform with regard to their specific applications, characterization techniques are required that can distinguish an ideal from a nonideal morphology. In this work, we investigated poly(tetrafluoroethylene)–poly(methyl methacrylate) (PTFE–PMMA) and poly(tetrafluoroethylene)–polystyrene (PTFE–PS) polymer CSNPs with a constant core diameter (45 nm) but varying shell thicknesses (4–50 nm). As confirmed by transmission scanning electron microscopy (T-SEM), the shell completely covers the core for the PTFE–PMMA nanoparticles, while the encapsulation of the core by the shell material is incomplete for the PTFE–PS nanoparticles. X-ray photoelectron spectroscopy (XPS) was applied to determine the shell thickness of the nanoparticles. The software SESSA v2.0 was used to analyze the intensities of the elastic peaks, and the QUASES software package was employed to evaluate the shape of the inelastic background in the XPS survey spectra. For the first time, nanoparticle shell thicknesses are presented, which are exclusively based on the analysis of the XPS inelastic background. Furthermore, principal component analysis (PCA)-assisted time-of-flight secondary-ion mass spectrometry (ToF-SIMS) of the PTFE–PS nanoparticle sample set revealed a systematic variation among the samples and, thus, confirmed the incomplete encapsulation of the core by the shell material. As opposed to that, no variation is observed in the PCA score plots of the PTFE–PMMA nanoparticle sample set. Consequently, the complete coverage of the core by the shell material is proved by ToF-SIMS with a certainty that cannot be achieved by XPS and T-SEM.
The elemental composition of thin Fe-Ni alloy films deposited on silicon substrates were determined by electron probe microanalysis with an energy dispersive spectrometer using the STRATAGem software. The work was part of ample inter-laboratory comparisons organized in the frame of CCQM/SAWG (Consultative Committee for Amount of Substance/Surface Analysis Working Group). Therefore, the evaluation of the measurement uncertainties is treated in detail. By having the mass coverage and estimating a layer density, the layer thickness could be derived.