Filtern
Dokumenttyp
Sprache
- Englisch (3)
Schlagworte
- Rare earth elements (3)
- Critical raw materials (1)
- Elemental analysis (1)
- Fluorescence lamps (1)
- Hg distribution (1)
- Mercury (1)
- Microwave-assisted digestion (1)
- Resource recovery (1)
- WEEE (1)
- Yttrium (1)
This study compares the mercury distribution in the vapor phase, the phosphor powder and the glass matrix of new and spent fluorescent lamps. The spent fluorescent lamps were obtained at the collection yards of a public waste management company in Hamburg, Germany. An innovative systematic sampling method is utilized to collect six spent and eight corresponding new, off-the-shelf fluorescent lamp samples. The efficiency of several acid digestion methods for the determination of the elemental composition was studied and elemental mass fractions of K, Na, Y, Ca, Ba, Eu, Al, Pb, Mg, Hg, and P were measured. The study also finds aqua regia to be the best reagent for acid digestion. However, no significant difference in mercury distribution was found in the different phases of the new and spent fluorescent lamps.
Recovery of rare earth elements - optimized elemental analysis of fluorescent lamp shredder waste
(2016)
Rare earth elements (REE) are a crucial component of fluorescence lamps. Several procedures have been developed to recovery these technological important elements. Nevertheless, actual REE recycling from fluorescence lamps is scarce so far (recovery rate of less than 1 %), with current recycling approaches concentrating on glass recovery. Since most recycling processes include several, also wet-chemical steps, a complete knowledge of the actual elemental composition of the respective mass flows is necessary for an efficient REE recovery. We tested seven different reagent mixtures for microwave-assisted digestion of fluorescent lamp shredder, including HF, HClO4, and H2O2. We determined the concentrations of 25 of the most relevant rare earth and other trace elements in the respective dilutions. Two independent digestions, one a mixture of perchlorid/nitric/hydrofluoric acid and the other aqua regia, showed the highest concentrations of 23 of these elements, excluding only Sn and Tb. The REE concentrations in the tested lamp shredder sample (stated in g/kg) were 10.2 (Y), 12.1 (La), 7.77 (Ce), 6.91 (Eu), 1.90 (Gd), and 4.11 (Tb).
Fluorescence lamps contain considerable amounts of rare earth elements (REE). Several recycling procedures for REE recovery from spent lamps have been established. However, despite their economic importance, the respective recycling is scarce so far, with an REE recovery rate of less than 1%. A reliable analysis of REE and other relevant metals like Yttrium is crucial for a thorough and complete recovery process. This applies both to the solid matter and aqueous phase, since most of the recycling processes include wet-chemical steps. We tested seven different reagent mixtures for microwave-assisted digestion of fluorescent lamp shredder, including hydrofluoric acid, perchloric acid, and hydrogen peroxide. We determined the concentrations of 25 of the most relevant rare earth and other trace elements (Al, P, Ti, V, Cr, Fe, Ni, Cu, Ga, Ge, As, Y, Ag, Cd, Sn, Sb, La, Ce, Eu, Gd, Tb, W, Au, Hg, and Pb) in the respective dilutions. Two independent digestions, one a mixture of perchlorid/nitric/hydrofluoric acid and the other aqua regia, showed the highest concentrations of 23 of these elements, excluding only Sn and Tb. The REE concentrations in the tested lamp shredder sample (stated in g/kg) were 10.2 (Y), 12.1 (La), 7.77 (Ce), 6.91 (Eu), 1.90 (Gd), and 4.11 (Tb).