Organisationseinheit der BAM
Mechanical stress often accelerates the failure of polymer materials. The aim of this research is to study the interaction between the sealing material FKM and biofuels B10 (heating oil with 10% biodiesel). The mechanical stress test was carried out in a special apparatus. Both mechanical and non-mechanical stress tests were conducted on specimens at 20, 40, and 70 °C for 28 days to document changes in mass, volume, and tensile properties. Both increasing temperature and mechanical stress have a significant effect on the tensile strength of the FKM polymer when exposed to B10. The combination of increasing temperature and mechanical stress induced rupture within 2 h. It was also established that FKM polymer with pre-exposure in B10 survived longer during mechanical stress compared to specimens exposed only to air. With the support of infrared (IR) spectroscopy, we were able to confirm the penetration of B10 into the FKM polymer.
Nebulizing of polymer solutions, in a high-voltage field under atmospheric conditions by electrospray ionization (ESI), is a comfortable way to deposit ultra-thin layers of polar or ionic polymers onto any conductive substrate materials. The substrate is grounded and the polymer solution is sprayed through a powered capillary. The formed charged droplets shrink by solvent evaporation during their way to the grounded substrate, the charges close ranks and the droplets collapse consecutively by charge repulsion, thus forming finally charged single macromolecules. After their discharging at the grounded substrate, an ultrathin ‘quasi-monomolecular’ polymer layer is formed. It could be shown by imaging of scratches through the polymer layer by atomic force microscopy that the deposited polymer layers are dense at a thickness of about 10 nm. Carbon fibre bundles were coated with poly (allylamine) (PAAm) or poly(acrylic acid) (PAA) as potential adhesion-promoting layers in fibre–polymer composites. The polymer deposition is self-inhibiting after formation of a continuous coverage of about 200 nm for PAAm and 30 nm for PAA as result of surface charging. Continuous deposition onto such isolating layers or polymers without charging can be achieved by using current of alternating polarity. The film formation is self-healing because of the electrophoretic effect, i.e. the ion discharging occurs preferentially at noncoated areas. This electrophoretic effect of ESI was demonstrated by completely enwrapping all the carbon fibres of the roving within a distance of about 100 μm far from its outside and also at the backside of the fibre bundle with about 80% of the topside coverage, as measured by X-ray photoelectron spectroscopy and visualized using scanning electron microscopy.
Die Elektrospray-Ionisations (ESI)-Vernebelung von Polymerlösungen wird analytisch zur massenspektrometrischen Bestimmung der Molmassen von Makromolekülen genutzt. Dabei werden die Polymermoleküle nach einem speziellen Mechanismus im Hochspannungsfeld unter Normaldruckbedingungen vereinzelt und in das Massenspektrometer überführt. Dieser Prozeß kann auch zur flächigen Abscheidung einzelner Polymermoleküle genutzt werden. Die Struktur und Zusammensetzung sowie die Molmassenverteilung der Polymere bleiben dabei erhalten. Schichten polarer oder ionischer Polymere der Dicke einer Quasi-Monolage bis hin zu mehreren 100 Nanometern können abgeschieden werden. Erwähnenswert ist, daß der ESI-Prozeß zu den elektrophoretischen Verfahren gehört, was die Ausbildung lochfreier Schichten auf elektrisch leitenden Substraten nicht nur auf der der Spraydüse zugewandten Seite ermöglicht, sondern auch auf der abgeschatteten Rückseite. Dieses Verhalten wurde zur vollständigen ESI-Umhüllung von dichtgepackten Kohlenstoff-Faser-Bündeln mit haftvermittelnden Polymerschichten ausgenutzt.
Plasma polymers and electrospray-ionization (ESI) polymer layers are compared for most efficient adhesion promotion in carbon fiber-epoxy resin composites. The ultra-thin ESI layers (2–30 nm) of commercial poly(acrylic acid) and poly-(hydroxyethylmethacrylate) produce an significant increase of adhesion measured by single-fiber pull out tests.
However, plasma Treatment has also advantages, such as simultaneous activation of the fiber substrate. Chemical structure and composition are rather far from the regular structure of commercial polymers as deposited by ESI processing.