Filtern
Erscheinungsjahr
Dokumenttyp
- Beitrag zu einem Tagungsband (31) (entfernen)
Sprache
- Englisch (31) (entfernen)
Schlagworte
- Concrete (5)
- Non-destructive testing (5)
- Inspection (3)
- Bluetooth (2)
- Concrete bridges (2)
- Debonding (2)
- Ground penetration radar (2)
- Moisture (2)
- Monitoring (2)
- Non-Destructive Testing (2)
Organisationseinheit der BAM
Within the presented research project, experimental and numerical investigations were performed to develop a thin-shelled, modular, mobile element system made of a micro-reinforced ultra-high-performance ductile concrete (DUCON®). Material parameters were experimentally determined to adapt the material model within the numerical analysis applying the Drucker-Prager relationship. Afterwards, for validation of the numerical models, quasi-static and high-velocity impact tests were performed on plate-like structures. Finally, a suitable geometry of transportable barrier elements will be designed, which provides a maximum of resistance against impact by a minimum of weight and a maximum of mobility.
The vulnerability of low-quality concrete of some bridges to ageing and deterioration while they are exposed to environmental conditions during their service life, influence of growing population and climate changes, is a well-known effect and requires survey. For survey, the development of a low cost, cost-efficient sensor network to be embedded for continuous or attached to the surface for periodic monitoring is essential.
Changing ground water conditions, flood or even leakage in fresh or disposal of waste water can lead to in-creased moisture content in building materials and structural elements as walls or floors. Moisture allows the transport of other adverse chemicals that might reduce the durability of structures. The paper presents a feasibility study about the capability of microwave modules as bluetooth® or ZigBee with frequency range at 2,4 GHz to create advanced Wireless Sensor Networks (WSN) for estimation and visualization of moisture distribution in infrastructure assets. It was found that the value of the received signal strength indication (RSSI) depends on the moisture content and can be the basis for the moisture distribution inside a massive structure.
The microwave modules may be used to compose networks outside and inside of building materials or structural elements. The higher the number of connections between BLE modules, the more precise and the more distant information can be obtained from the network. Mesh networking was applied to increase the quantitative information.
The presented development of a damping model is a research component of an experimental feasibility study about moisture in building materials measured with Bluetooth® Low Energy (BLE) signals. This study may be part of a structural health monitoring aiming on early damage detection in the built infrastructure and is increasingly focusing on wireless sensor Network technology. It is investigated, how the Received Signal Strength Indicator (RSSI) of a BLE signal, transmitted from the BLE-module embedded in building materials with changing moisture content is damped. The BLE-module communicates with a mobile Smart Device as tablet or mobile phone via 2.45 GHz-ISMfrequency band where water dipoles start to oscillate. If the BLE-signal transfers through a moist material, the moisture Content influences the RSS-Indicator. The damping model demonstrates this damping effect on RSSI by the abstraction of the reality observed in a real system.
The amount of new knowledge about bridges, materials they are made of, deterioration processes for the different materials, resulting defects, methods for early detection of them and related causes for damage increases day by day. Often the knowledge remains in the heads of ageing specialists leaving the inspection teams or universities. This paper presents a feasibility study about application of a new tool from artificial intelligence to model and organize bridge engineering knowledge from a domain expert´s view. Exemplarily, knowledge and not only data from bridge testing in the field and in the laboratory were formalized for the presentation of the functionality of ontologies.
Cast iron arch bridges were built in the late 18th and early 19th century across Europe. After the famous Iron Bridge in the Ironbridge Gorge in Coalbrookdale in England, being now part of the UNESCO world heritage, many cast iron bridges followed and substituted timber bridges. A series of cast iron bridges has been built in central Europe, in Laasan, Breslau, (now Wrocław), in Berlin, Potsdam, Bad Muskau and Schwerin. The paper gives an overview about the current state of some remaining cast iron arch bridges, typical damage cases, material properties and rehabilitation. Most of the old cast iron arch bridges serve as pedestrian bridges. Some of these bridges have been strengthened to increase the traffic load. Different rehabilitation measures as substitution of parts of the bridges and strengthening using Carbon Reinforced Polymers (CFRP) are discussed.
Berlin Main Station is the largest multi-level station in Europe. Its daily passenger number amounts to over 300.000. Structures built for such a large number of people require a high-level safety standard. The station was built on the inner city site of the historic Lehrter Bahnhof. The conditions for building and start of operation were challenging by several reasons. The typical sandy ground with a high level of groundwater makes the permanent static stability of such a complex structure difficult. Several completed, ongoing, and planned construction activities in the immediate vicinity of the station influence the ground settlement of the whole area. On basis of the structural design an impact prediction was calculated, which expected certain vertical displacements particularly between the single columns of the outer concrete bridges of the building. These columns support the glass roof construction, which only allows a defined limit of displacement. In order to avoid damage, a concept for monitoring and adjusting potentially occurring displacements was developed for installation at the outer bridges of the station.
Structural health monitoring contributes to early damage detection in the built infrastructure. During the last two decades, the sensor networks transferred from wired to wireless sensor networks.
Several methods exist to measure moisture in building materials. Most of the introduced commercial humidity measurement methods as provide information about the local or near surface moisture. A feasibility study is presented to demonstrate, how the Received Signal Strength Indicator (RSSI) of a BlueTooth® Low Energy (BLE) signal, transmitted from the BLE-module embedded in building materials with changing moisture content. The BLE-module communicates with a mobile Smart Device as tablet or mobile phone. The RSSI indicates to what extend the received signal strength is changed due to moisture, while the transmitted signal strength remains constant.
The amount of new knowledge about bridges, about the materials they are made of, deterioration processes for the different materials, typical defects, methods for early detection of them and related causes for damage increases day by day. Often the knowledge remains in the heads of ageing specialists leaving the inspection teams or universities. This paper presents a feasibility study about application of a new tool from artificial in-telligence, ontology, for modeling and organizing bridge engineering knowledge from a domain expert´s view. Exemplarily, knowledge and not only data from bridge testing in the field and in the laboratory were formalized for the presentation of the functionality of ontologies. The open source ontology editor Protégé was ap-plied to test the feasibility.
Trans-European corridors for transport of people and goods require strengthening of bridges to carry increased axle loads in terms of absolute axle loads and of their frequency. Most of the bridges along highways are reinforced or prestressed concrete bridges.
Since the late 1990s, CFRP laminates have been applied to box girder and T-beam bridges to increase the overall capacity. Although regular inspections are carried out, no special method was available to test the bond condition of CFRP laminates after being in Service for more than ten years. The German Center of Competence in Civil Engineering is aware of this need and funded a research project to investigate the bond condition by means of advanced non-destructive testing (NDT).
The research project "Ultrasonic Net for Concrete Monitoring (UNeCOM)" aims at developing a methodology for an embedded ultrasonic network for the condition assessment of infrastructure constructions. Civil engineering structures made of concrete, which are located in tectonically active regions or undergo special loading conditions, may require continuous monitoring. It is important to assess the condition of the building and its stability to recognise and classify the effect of a seismic event or evolving damage at early stages before failure occurs. Embedded ultrasonic sensors offer the possibility to detect changes in the material and degradation mechanisms from inside the structure in areas which are difficult or impossible to inspect otherwise. In contrast to conventional ultrasonic testing methods, where the concrete surfaces are scanned with ultrasound probes, this new approach uses sensors, which are embedded into concrete, eliminating the effect of variable coupling conditions between sensors and concrete. This method allows an integral detection of changes in the concrete structure, for example due to seismic activities, to detect mechanical impacts, as well as degradation of the material due to overloading. Such methods have great relevance especially for the monitoring of constructions like power plants, bridges, offshore structures and other structures with high technical safety requirements. The sensor network can be controlled remotely through the internet which is also being used for data transfer. The embedded sensor network is designed to monitor structural damage and concrete degradation globally with high sensitivity.
Ultrasound sensors should be embedded into concrete for monitoring concrete properties. These new longitudinal wave sensors with a center frequency of 60 kHz were examined regarding their suitability for ultrasonic measurements in concrete structures in terms of emission characteristics, sensitivity and frequency ränge.
For the measurement of the radiation patterns, the sensors were embedded vertically and horizontally in concrete cylinders. The directivity pattern was measured using a laser vibrometer.
The sensitivity of the sensor was determined in water using different sensors of the same type. It shows changes in the signal amplitude as well as variations in the frequency ränge for different transmitter-receiver combinations.
The attenuation of the concrete affects the achievable resolution of the measurements and thus, the maximum possible spacing of the sensors within a concrete element. Experimental tests helped optimizing the distances with respect to the required resolution and the effort of embedding the sensors. The signal attenuation in the concrete was measured in the frequency ränge of 60 kHz in response to various degrees of reinforcement and grain size. For this purpose, the sensors were cast at different distances in the specimens studied. The recorded Signals were evaluated for their amplitude and frequency spectrum.
In this research, laboratory experiments were carried out to investigate the feasibility of using ground penetrating radar (GPR) for corrosion detection and/or monitoring, and the mechanism of corrosion caused GPR signal changes, taking into account the influence of several parameters: Chloride, rebar size and cover depth. With the understanding of the mechanism, a novel method for detecting reinforcement corrosion in concrete with GPR is proposed, together with a series of signal processing toolkits for corrosion visualization and image comparison.
Monitoring accelerated corrosion in chloride contaminated concrete with ground penetrating radar
(2012)
In 1882, the East-West suburban train viaduct was built through Berlin as part of the public traffic solution in the late 19th Century. Today, the only left over iron arch bridge is a pair of two arches Crossing the Spree river in the middle of Berlin. Before dismantling the former parallel two original pairs of iron arches and rebuilding new arches for the high-speed railway line through Berlin in 1997, BAM was involved in an extensive test program of the heritage iron arch structure. Especially the estimation of accumulated damage in critical details and the verification of the old material properties at early stage was important information to the bridge owners. The testing program included two strain and displacement measurement campaigns, non-destructive testing, materials testing and microscale metallographic analysis of critical details. The measured strain cycles were significant lower in number and size than expected. Most of the cycles were compression stress cycles only. The work was planned in Cooperation with the Berlin consultancy Professor Hilbers that was responsible for the design and calculation of the reconstruction measures. Additionally, after calculation of the possible reuse of the old arches, we compared measured data from strain measurements with the results from calculation.
The measured data and the calculated data show a good qualitative correlation.