The European infrastructure asset has developed historically and is characterized by nation-specific construction processes. Inspection, condition assessment, and maintenance procedures differ from country to country. Because of historical and political circumstances, national infrastructure assets are maintained at different levels, too. Since the budget for maintaining the bridge infrastructure less and less meets the demands of a growing bridge stock, bridge inspection, maintenance, and life-cycle considerations gain higher importance. The need exists to develop effective diagnosis tools for early detection of construction faults, defects, and deterioration processes during inspection, to keep the bridge infrastructure at an acceptable level, from structural safety and economic viewpoints. An overview on the latest research projects and integrated bridge management systems in Europe is given. The potentials of nondestructive testing (NDT) are presented, with special focus on technical advances of NDT applications to reinforced concrete (RC) and posttensioned concrete bridges. Although NDT is not regularly integrated in these processes, the application brings valuable information on the current condition of the inner structure in called-in special inspections. NDT-automation and the application of imaging echo methods, combined with advanced data processing, produce a surprising level of information about the inner structure of massive RC slabs up to a depth of about 60 cm. Detected inhomogeneity and scatterers of acoustic or electromagnetic waves can be visualized in vertical or horizontal slices through the structure or animations. The fusion of different three-dimensional data sets of processed data improves the interpretability and accuracy of the results.
Complex special inspection of an old masonry arch bridge according to the Guideline on Inspection and Condition Assessment of Railway Bridges and numerical analysis of the structure are presented. The guideline summarises recommendations for the step-by-step investigation of railway bridges applying enhanced methods developed during the EU-funded project Sustainable Bridges. For the investigation of the arch barrel, the ballast parameters and the inner structure of the backfill behind the arch barrel a number of various advanced non-destructive and minor-destructive testing methods were applied. Deformation of the structure during load tests was measured using three independent measuring systems: laser vibrometer, LVDT and microwave radar. Results of calculations performed with 2D and 3D models based on FEM are compared with the field load tests. Sensitivity of the ultimate load of the structure to investigated parameters is studied in FE model. Some general conclusions according to methods of testing and modelling of masonry arch bridges are presented and discussed.
Complex special inspection of an old masonry arch bridge according to the Guideline on Inspection and Condition Assessment of Railway Bridges and numerical analysis of the structure are presented. The guideline summarises recommendations for the step-by-step investigation of railway bridges applying enhanced methods developed during the EU-funded project Sustainable Bridges. For the investigation of the arch barrel, the ballast parameters and the inner structure of the backfill behind the arch barrel a number of various advanced non-destructive and minor-destructive testing methods were applied. Deformation of the structure during load tests was measured using three independent measuring systems: laser vibrometer, LVDT and microwave radar. Results of calculations performed with 2D and 3D models based on FEM are compared with the field load tests. Sensitivity of the ultimate load of the structure to investigated parameters is studied in FE model. Some general conclusions according to methods of testing and modelling of masonry arch bridges are presented and discussed.