Cast iron arch bridges were built in the late 18th and early 19th century across Europe. After the famous Iron Bridge in the Ironbridge Gorge in Coalbrookdale in England, being now part of the UNESCO world heritage, many cast iron bridges followed and substituted timber bridges. A series of cast iron bridges has been built in central Europe, in Laasan, Breslau, (now Wrocław), in Berlin, Potsdam, Bad Muskau and Schwerin. The paper gives an overview about the current state of some remaining cast iron arch bridges, typical damage cases, material properties and rehabilitation. Most of the old cast iron arch bridges serve as pedestrian bridges. Some of these bridges have been strengthened to increase the traffic load. Different rehabilitation measures as substitution of parts of the bridges and strengthening using Carbon Reinforced Polymers (CFRP) are discussed.
Condition assessment of old railway bridges, a scientific cooperation between Berlin and Wroclaw
(2009)
Current measurement methods for dertermination of moisture analyse near-surface moisture distribution. During an externally funded research project, microwaves in the Bluetooth(R) frequency band width were utilized for Setting-up a module network. Without additional sensors, the feasibility study confirmed that threedimensional data can collected to obtain a threedimensional data set as basis for the estimation of moisture distribution inside massive building materials.
Civil engineers, who are involved in nondestructive testing have to solve an essential task: the transfer of the results of NDT-research into practice. NDT in civil Engineering is a quite new discipline. The results must meet the needs of the infrastructure owners to convince them about the usefulness of NDT. The issue of reliability of the NDT-data was discussed.
The Berlin Main Station was built between 2000 and 2006. At the occasion of the 10th anniversary after the Berlin Main Station was officially opened to train traffic, a view back on eight years of monitoring was given. For the period of the construction with different load cases, the monitoring system was required by the Railway Authorities (Eisenbahnbundesam, EBA) to survey differential vertical displacements between neighbouring supports of the glas roof and the partially prestressed middle bridges. 128 sensors were installed.The data was published in the Internet with access restricted to the BAM scientists and the owner of the station, the German Railways DB AG.
Measurements, NDT and laboratory testing of the wrought iron bridge at Berlin-Friedrichstraße
(2010)
Messungen und Laborversuche an der schweißeisernen Spreebrücke an der Berliner Friedrichstraße
(2010)
Opportunities and Limitation of Non-destructive Testing in Condition Assessment of Bridge Structures
(2009)
Practical applications of recent BAM-research results of NDT and monitoring in civil engineering
(2018)
Nondestructive testing and monitoring was of mayor interest in BAM-research related to the survey of civil engineering structures during the last two decades. Three case studies about research projects carried out at BAM were presented. All three projects focussed on the survey of parameters and safety related tasks in bridge engineering and inspection. First, the monitoring of the Berlin main station was presented with focus on the sensors developed specifically for this project. The second case study presented and application of guided ultrasonic waves to CFRP-strengthened bridges. The method was sucsessully applied to two of four different strengthening measures carried out min. 10 years ago. The last project presented the feasibility study of a network consisting of simple Bluetooth modules to survey changes in the moisture content in sand and massive concrete.
The reliability of data, obtained from nondestructive testing depends on many different factors as e.g. the equipment, the human factor, the influence of material properties, geometrical accessibility of the given detail, the structure of the detail, but also from data acquisition, processing and interpretation. The presentation introduces to current possibilities for the quantification of measurement results received during nondestructive testing.