Filtern
Dokumenttyp
Schlagworte
- BEMMA (4)
- Air sampling (2)
- Bauprodukte (2)
- Blauer Engel (2)
- Bürogeräte (2)
- Laserdrucker (2)
- Museum (2)
- Partikelemissionen (2)
- Präventive Konservierung (2)
- VOC (2)
- Vitrinen (2)
- Acetic acid (1)
- Acetic and formic acid (1)
- AgBB-Schema (1)
- Assessment of emissions from materials for museum equipment (1)
- Ausstellungsvitrinen (1)
- BEMMA display case (1)
- Biocide (1)
- Bürogeräte mit Druckfunktion (1)
- Bürogeräte mit Laserdruckfunktion (1)
- Chamber study (1)
- Chemische Emissionen (1)
- Climate control device (1)
- Conductivity (1)
- DNPH (1)
- Detection of formic and acetic acid (1)
- Display case (1)
- Emission (1)
- Emissions (1)
- Emissionsarme Vitrine (1)
- Emissionsarme Vitrinen (1)
- Emissionsmessung (1)
- Emissionsmessungen (1)
- Essigsäure (1)
- Feine und ultrafeine Partikel (1)
- Formic acid (1)
- Geruch (1)
- Kleinklimagerät (1)
- MVOC (microbial volatile organic compounds) (1)
- Material emission (1)
- Messmethoden (1)
- Microbiological contamination (1)
- Normung (1)
- Partikelemission (1)
- Protection of cultural object (1)
- Quantification of formic and acetic acid (1)
- RAL-UZ 122 (1)
- SVOC (1)
- Schadstoffe (1)
- Schimmelpilze (1)
- VOC-emission (1)
- VOCs (1)
- VVOCs (1)
- Verpackungsmaterialien (1)
- Vitrine (1)
- Wood (1)
Organisationseinheit der BAM
Nicht nur Schadstoffe aus der Umwelt können Museumsexponate schädigen. Auch interne Schadstoffquellen wie objektimmanente Exhalate und Emissionen von Lösemitteln oder organischen Säuren können den wertvollen Gu¨tern Schaden zufu¨gen. Auf Schadstoffe zu pru¨fen sowie geeignete Messmethoden zu entwickeln und zu optimieren, ist daher von großer Bedeutung. Neuste Forschungen stellen die Autoren vor.
Moderne Vitrinen sollen gleichzeitig eine hohe Dichtigkeit und die Abwesenheit jeglicher Fremdstoffe in den Vitrinen gewährleisten. Diese Anforderungen sind zeitgleich kaum erfüllbar, da es emissionsfreie Materialien (vor allem Kleb- und Beschichtungsstoffe) nicht gibt. Um die potentiellen Emissionen zu minimieren wurde ein Messverfahren entwickelt, welches inzwischen als BEMMA-Schema (Bewertung von Emissionen aus Materialien für Museumsausstattungen) in die Museumswelt Einzug genommen hat.
Die erfolgreiche Bewertung der für den Bau verwendeten Materialien gemäß BEMMA-Schema resultiert nicht in einer emissionsfreien Vitrine, sondern soll bei der Auswahl geeigneter Materialien zur Herstellung möglichst emissionsarmer Vitrinen helfen. Konkrete handwerkliche Durchführungen beim Bau, Dichtheits¬anforderungen, wie auch die Aufstellbedingungen (Umgebung der Vitrine) beeinflussen die Emissionscharakteristik der fertigen Vitrine in der Praxis. Eine saubere Vitrine hilft nichts in einer belasteten Umgebung oder auch bei emittierenden Exponaten. Inzwischen liegen Erfahrungen mit dem Schema seit 2012 vor.
Der Messablauf sieht vor, dass von den Materialien kleine Muster mit der Mikrokammer (Markes) innerhalb von 2 Tagen untersucht werden. Dabei wird mit Silikagelkartuschen auf Ameisen- und Essigsäure, mit DNPH auf Aldehyde und Ketone und mit Tenax® sowohl auf VOC als auch für die spezifische Oxim-Analytik die Abluft der Mikrokammern untersucht. Die Bewertungskriterien basieren auf den Ergebnissen einer Vorstudie mit ca. 150 verschiedenen Produkten im Zeitraum 2010 bis 2012.
Museumsvitrinen sollen Kunst- und Kulturgut „ins rechte Licht“ setzen und vor Diebstahl oder Vandalismus schützen. Vergleicht man historische Schauvitrinen, die zumeist aus einfachen Glasscheiben in Holzrahmungen bestehen, mit heutigen Konstruktionen, lässt sich eine Entwicklung zu hochtechnisierten Gebilden ablesen, die deutlich mehr Ansprüchen genügen müssen als in der Vergangenheit.
Zahlreiche Beispiele verdeutlichen, dass Kunstwerke nicht nur außerhalb, sondern auch innerhalb von Museen oder Archiven ungünstigen Umwelteinflüssen ausgesetzt sind. So können Einbauten bzw. Dekorationen in Ausstellungsräumen, Aufbewahrungsbehältnisse in Depoträumen oder Ausstellungsvitrinen flüchtige Substanzen, sogenannte VOCs (Volatile Organic Compounds) freisetzen, die zu irreversiblen Veränderungen an den Objekten führen und diese schädigen. Hierzu zählen organische Säuren, wie Ameisen- oder Essigsäure, aber auch Verbindungen, die Sulfide enthalten. Hier wird die an der BAM entwickelte BEMMA-Bewertungsmethode vorgestellt, die von Museen verwendet werden kann Materialien mit einem geringeren Emissionspotential auszusuchen.
Do particleboards produced with recycled wood contribute to indoor air pollution with biocides?
(2003)
Schadstoffe beschäftigen derzeit Museen weltweit Heute weiß man, dass diese auch aus Materialien, die für den Ausstellungsbau verwendet werden, austreten können, was eine Gefahr für Exponate darstellt. Ein neues Verfahren namens BEMMA bietet nun erstmalig die Möglichkeit, relativ schnell und effektiv eine problemorientierte Untersuchung und Bewertung mit belastbaren und reproduzierbaren Ergebnissen vorzunehmen.
Formic and acetic acids are often responsible for damage of cultural objects, e. g. glass and metal corrosion or changing and fading of colours. Museums all around the world are equipped with different show cases. Display cases should protect cultural objects from dust as well as from mechanical damage. Several construction materials which are used for display cases, including wood, glue and coatings, are possible sources of very volatile organic compounds (VVOCs), volatile organic compounds (VOCs) and semi volatile organic compounds (SVOCs). These construction products can emit formic and acetic acids into the indoor or display case air. Modern display cases with small air change rates can cause higher concentrations of formic and acetic acids if any source is installed in the display case (Salthammer and Uhde, 2009). To minimize the risk of damage emissions from building products must be quantified. There is a need for a method for identification and quantification of acetic and formic acid. Some possibilities for the identification of acetic acid exist. The quantification of acetic acid for example after sampling on TENAX® or CARBOTRAP and thermal desorption-GC in accordance with ISO 16000-6 and ISO 16017-1 results in very low recovery rates. A new method should be stabile, robust, reproducible and comparable, with an easy local sampling and determination in laboratories. Miniaturised emission test chambers and model display cases were used to study the recovery rates.
Several construction and building materials, including wood, glue and coatings, are possible sources of very volatile organic compounds (VVOCs) and volatile organic compounds (VOCs) like formic and acetic acid. Due to very high air tightness and very low air exchange rates in new buildings concentrations of these harmful substances can increase considerably. To minimize the risk, emissions from building products should be identified and quantified. With the common standard method, this means Tenax® sampling followed by thermal desorption and GC-MS analysis, these acids could not be detected sufficiently. The aim oft this study is the comparison of two different methods for the determination of acetic and formic acid. The sampling of method one, which is usually used for identification and quantification of VOCs, is done in accordance with ISO 16000-6 and ISO 16017-1 on Carbotrap® 202 multi-bed thermal desorption tube by subsequent identification and quantification with GC-MS. Method two is based on sampling on 2,4-dinitrophenylhydrazine (DNPH) cartridges, derivatisation, elution, identification and quantification of the derivatives with LC-MS/MS (liquid chromatography mass spectrometry/mass spectrometry).
Ausstellungskuratoren, Restauratoren oder Fachplaner stehen immer wieder vor der Entscheidung, geeignete Materialien für Museumsausstattungen auswählen zu müssen. Vitrinen, Depoteinrichtungen, aber auch Transportverpackungen für Kunst- und Kulturgut sollten unbedingt frei von Schadstoffen sein. Ein neues Verfahren ermöglicht nun eine problemorientierte Untersuchung und Bewertung von Materialien mit belastbaren und reproduzierbaren Ergebnissen.
Unterschiedliche Befeuchtungssysteme für Vitrinen, die die Ausstellungsobjekte bei definierter Luftfeuchtigkeit vor externen Einflüssen wie Staub bewahren sollen, wurden im Hinblick auf die Möglichkeit der potenziellen mikrobiologischen Kontamination untersucht. Ergänzend hierzu wurden Parameter wie pH-Wert und Leitfähigkeit des Wassers im Befeuchter untersucht und die mikrobiellen flüchtigen organischen Verbindungen (MVOC, microbial volatile organic compounds) in der Modellvitrine bestimmt. Die Leitfähigkeitsmessung kann als Indikator für den Verunreinigungsgrad des Wassers dienen, weil sie mit der mikrobiologischen Belastung korreliert. Weiterhin war eine mikrobiologische Belastung der Luft in der Modellvitrine auch bei relativ hoher Verunreinigung des Befeuchtungswassers nicht nachzuweisen.
Vor dem Hintergrund der anhaltenden öffentlichen Diskussion um mögliche gesundheitliche Risiken von Ultrafein- und Feinstaubemissionen aus Bürogeräten mit Laserdruckfunktion (LPD, Laser Printing Device) wurde vom Umweltbundesamt ein Forschungsvorhaben zur Entwicklung einer Prüfprozedur für die Quantifizierung der emittierten Partikel durch Zählung unter Standardbedingungen in Emissionsmesskammern, sowie zur physikalischen und chemischen Charakterisierung dieser Aerosole initiiert. Als Ergebnis konnte die Partikelzählung in den Entwurf des Prüfverfahrens für die Bestimmung von Emissionen (RAL-UZ-122, Anhang S-M) des Umweltzeichens "Blauer Engel" für Bürogeräte sowie in den Prüfstandards ECMA-328 und den Entwurf der ISO/IEC 28360 integriert werden. Die Methode wurde in einem internationalen Ringversuch erfolgreich getestet. Auf dieser Basis können Vergabekriterien und -werte für die Emission von Fein- und Ultrafeinpartikeln im Rahmen der Vergabe des Umweltzeichens Blauer Engel vereinbart und Produktprüfungen vorgenommen werden.