Filtern
Dokumenttyp
- Posterpräsentation (27)
- Vortrag (26)
- Forschungsdatensatz (4)
- Sonstiges (3)
- Zeitschriftenartikel (2)
- Beitrag zu einem Tagungsband (2)
- Dissertation (1)
- Forschungsbericht (1)
Referierte Publikation
- nein (66) (entfernen)
Schlagworte
- DNA (45)
- Dosimetry (44)
- Geant4 (44)
- Microdosimetry (36)
- Radiation damage (33)
- Geant4-DNA (28)
- LEE (25)
- Low energy electrons (22)
- MCS (22)
- Radiation therapy (17)
Organisationseinheit der BAM
- 6 Materialchemie (57)
- 6.6 Physik und chemische Analytik der Polymere (57)
- 6.1 Oberflächen- und Dünnschichtanalyse (7)
- 6.5 Synthese und Streuverfahren nanostrukturierter Materialien (3)
- 5 Werkstofftechnik (1)
- 5.1 Materialographie, Fraktographie und Alterung technischer Werkstoffe (1)
- 6.3 Strukturanalytik (1)
Eingeladener Vortrag
- nein (26)
Water structuring induced by Ectoine as a possible explanation for its protection against radiation
(2015)
Ectoine induced water structuring as a possible explanation for its radiation protection properties
(2015)
Radiation damage to DNA is one of the main causes for cancer and likewise a major tool in its treatment. One of the dogma of the classical radiochemistry and physics involves the opinion that radicals such as OH° produced by ionizing radiation are the most lethal agents. This scenario is increasingly disputed as secondary low-energy electrons are emerging [1] as important, if not predominant, reductive pathway in ionizing damage of biomolecules. These electrons are generated in copious amount in aqueous environment as secondary scattering products. But until now all research concerning the quantification of the effects of low energy electrons on the biomolecular damage was either performed in vacuum with low energy electron sources or with DNA plasmids on metallic surfaces in humid environment. In this work we present detailed experimental and simulation microdosimetry data on electron damage to plasmid DNA in liquid environment: Well-defined electron energy and dosage irradiation was achieve by using an EM and the irradiation through a nanomembrane. The results are analyzed in terms of single- and double-strand break probabilities in the dependence of dose, energy, number of primary and secondary electrons. The results are important not only from the basic scientific point of view but also for the development of effective radiosensitizers, either as protecting or enhancing (radiotherapy) cofactors.
In the last years, secondary low-energy electrons (LEE) emerged as important, if not predominant, reductive pathway in ionizing damage of biomolecules. These electrons are created in copious amount as result of inelastic scattering of high energy radiation at water. Until now, all experiments the quantification of the effects of LEEs on the biomolecular damage was either performed in vacuum with LEE sources or with DNA on surfaces in humid atmosphere.
We present a new experimental setup to irradiate biomolecules with electrons under physiological conditions. In combination with monte carlo simulations this setup makes it possible to determine microdosimetric quantities for biomolecules in liquid environment under electron irradiation.
This opens up new possibilities in radiation research to access the LEE damage under well defined physiological condition, for more complex systems, such as DNA-Protein complexes and even living cells.
Electron beam therpy is used to treat tumor cells by irradiation with high energy electrons (HEE). The irradiation is performed by medical linear accelerators.
By interaction of the HEE with the irradiated tissue a broad spectra of secondary electrons and water dissoziation products is generated.
These products interact with biomolecules, especially DNA, by various processes. The disentanglement of the resulting direct- and indirect damage to DNA and other cellular components is still under debate.
To increase the efficiency of future therapies a better understanding of the microscopic damaging processes is highly important.
Especially the various contributions of the secondary species produced, such as low energy electrons (LEE) and radicals is far from understood and quantified.
To increase the understanding we present a combination of a microdosimetric simulations and experiments to quantify the damage by means of electron scattering and diffusion simulations within the Geant4-DNA framework.
In combination with in-liquid irradiation of plasmid DNA it possible to determine microdosimetric quantities for biomolecules in liquid environment.
The presented method was applied to the irradiation of plasmid DNA (pUC19) in water.
This opens up new possibilities in radiation research to quantify the dosage-damage relationship for microscopic plasmid volumes under well defined physiological condition.
The damage caused by ionizing radiation to biomolecules, especially DNA, is the reason to treat cancer via radiation therapy. A better understanding of the molecular processes and the quantification of the various damaging mechanisms is the prerequisit to develope efficient therapies. Hereby the understanding of the processes involved in the damage to DNA are of key interest due to its central role in reproduction and mutation. Due to the high amount of water in biological tissue, most of the damage is caused by the secondary particles produced by the interaction of the IR with water. Thereby a multitude of species are produced, e.g. kinetic low energy electrons, prehydrated electrons, OH-radicals and ions. The quantification of the contribution to DNA damage of the various species is of interest. Here we present an experimental approach to disentangle their relative DNA strand break yield. Plasmid DNA is irradiated in water with electrons under the presence of different scavengers. With the presented method it will be possible to reveal the relative contributions of OH-radicals, low energy electrons and prehydrated electrons to the DNA single and double strand break yield.
We report on the design, preparation and application of immobilized Oligonucleotides as biological sensors for dosimetry and protein activity. Oligonucleotides can be custom tailored in terms of sequence and length to the needs of the specific application. The preparation can be scaled from small lab-scales to higher output via spotting technology on various surfaces such as glass, silicon-dioxide or gold. They can be applied for the sensing of DNA-protein interaction and surface-plasmon resonance to detect the influence of cosolutes on the protein activity. This can be applied in the testing of pharmaceutical or cosmsetic applications and incorporated in microfluidic devices. Other important use cases are the usage in dosimetric application where the oligonucleotides are subjected to ionizing radiation. They can directly act as a sensor for biological damage which is detected and quantified by the subsequent hybridization of complementary strands who carry a fluorescence dye. The quantification can be performed by an array scanner or fluorescence microscope. Investigation on a molecular level can be performed with the AFM-IR technique. Applications are calibration of radiation sources and the investigation of interaction of ionizing radiation with biomolecules.
In dosimetry the determination of the effectiveness of the damaging processes is standardized and accounted for by the radiation and tissue weighting factor. For the underlying constituents of the tissue, that is the various biomolecules, such a systematic approach doesn't exist. This makes it difficult to compare results obtained under different experimental conditions. In the following work, we will describe a method to obtain comparable values for the radiation-biomolecule interaction, measured under different conditions. This approach can lead to standardization of dosedamage relationship at the molecular level. Such approach is necessary for a better understanding of the relations between the damage of the single constituents of biological tissue and the whole – finally gaining a more complete picture of irradiation damage.
Quantifizierung der Schädigung von DNA in wässriger Lösung unter direkter Elektronenbestrahlung
(2018)
To cure cancer radiation therapy is used to kill tumor cells.
It is based on radiation induced damage to biomolecules.
Especially DNA damage is of key interest due to its central role in apoptosis and mutation.
Because of the high amount of water in biological tissue, most of the damage is caused by the secondary particles produced by the inelastic scattering of ionizing radiation and water.
A detailed understanding of the underlying molecular processes under physiological conditions is the prerequisite to develop more efficient therapies.
Goal of this work is to quantify the DNA damage caused by ionizing radiation in dependence of the inelastic scattering events and the energy deposit within the microscopic target volume of biological relevance.
The irradiations have to be performed in liquid, under consideration of the chemical environment.
Therefore, a new combination of experiment and Monte-Carlo simulations was developed and tested.
To make it possible to irradiate liquids with electrons within scanning electron microscopes a new sample holder was constructed incorporating an electron transparent nanomembrane.
It makes it possible to irradiate DNA, proteins or cells at different pH, salinity and in the presence of cosolutes.
%The most important results of this work are as follows:
The median lethal dose for a model system of plasmid DNA and water was determined by the combination of experimental data, particle scattering simulations (Geant4-DNA) and diffusion calculations as D0.5=(1.7+-0.3) Gy.
From the convolution of plasmid positions and the spatially resolved energy deposit, as determined by electron scattering simulations, the histogram of the energy deposit within the target volume of the plasmids and the microscopic median lethal energy deposit was calculated as E0.5=6+-4eV.
It could be deduced that on average less than two ionization events are sufficient to cause a single-strand-break.
The relation of single-strand-breaks (SSB) to double-strand-breaks (DSB), which is of importance for microdosimetric modeling, was determined as SSB:DSB = 12:1.
The presented method for the determination of microscopic dose-damage relations was further extended to be applicable for general irradiation experiments.
It becomes independent of the type of primary radiation used, the experimental geometry, and the diffusional properties of the molecules under investigation.
This way different experimental systems with varying, inhomogeneous energy deposit characteristics become comparable with each other, which is not possible when only macroscopic averaged values are taken into account.
In addition, the radiation protection properties of the compatible solute ectoine, as well as its influence on the water properties and biomolecules were investigated.
%In addition, the influence of the compatible solute ectoine on water, biomolecules and its radiation protection properties were investigated.
Raman spectroscopy revealed a concentration dependent increase of the collective water modes in the OH-stretching region, which was found to be independent of the sodium chloride concentration.
Molecular dynamic simulations showed that the zwitterionic properties of ectoine lead to its half-chair conformation.
The hydrogen bonds in the first hydration shell are more stable and have an increased lifetime compared to the bulk water.
Irradiation experiments with DNA in the presence of 1M ectoine revealed an increase of the survival rate by a factor of 1.41 as compared to the absence of ectoine.
The protective properties of ectoine result from the increase of the inelastic scattering probabilities of low energy electrons at the acoustic vibrational modes of water and its properties as OH-radical scavenger.
This was shown by Raman spectroscopy and electron paramagnetic resonance measurements (EPR).