Commercial, off-the shelf propane cylinders are subjected to high safety regulations. Furthermore, those cylinders are equipped with safety devices like pressure relief valves (PRV). Despite these regulations and safety measures, a failure of the container is possible if exposed to an intense fire. The result of this is severe hazard for users, rescue forces and infrastructure. Within the framework of a destructive test series, 15 identical propane cylinders, without pressure relief devices, were exposed to an intensive fire in horizontal position until failure. Each cylinder was filled with a mass of m =11 kg of liquid propane. Three different fire sources were used (wood, petrol, propane). The experiments revealed the failure of all cylinders in a time period t < 155 s. The failure lead to a fragmentation into several major parts with throwing distances of up to l =262 m. In all trials, the temperature of the cylinder wall (top, side, bottom), of the liquid phase inside and of the surrounding fire (top, side, bottom) was recorded. In addition, the inner cylinder pressure and the induced overpressure of the blast wave after the failure were recorded. Overpressures of up to p=0.27 bar were recorded close to the cylinder (l =5 m). All tests were documented by video from several positions (general view, close-up, high-speed 5000 fps). This test series creates the basis for further experimental studies in the field of alternative fuels for vehicles. The aim of this test series is to assess and analyse the consequences of the failure of gas vessels (for LPG, CNG, CGH2) in the aftermath of severe incidents.
In case of a vehicle fire, an installed LPG (liquefied petroleum gas) tank with a malfunctioning safety device poses severe hazards. To investigate the consequences in case of tank failure, we conducted 16 tests with toroidal shaped LPG vehicle tanks. Three tanks were used for a Hydraulic Burst Test under standard conditions. Another three tanks were equipped with a statutory safety device and were subjected to a gasoline pool fire. The safety device prevented tank failure, as intended. To generate a statistically valid dataset on tank failure, ten tanks without safety devices were exposed to a gasoline pool fire. Five tanks were filled to a level of 20 %; the re-maining five were filled to a level of 100 %. In order to gain information on the heating process, three tem-perature readings at the tank surface, and three nearby flame temperatures were recorded. At distances of l = (7; 9; 11) m to the tank, the overpressure of the shock wave induced by the tank failure and the unsteady tem-peratures were measured. All ten tanks failed within a time of t < 5 min in a BLEVE (boiling liquid expanding vapor explosion). Seven of these resulted directly in a catastrophic failure. The other three resulted in partial failure followed by catastrophic failure. A near field overpressure at a distance of l = 7 m of up to p = 0.27 bar was measured. All ten tests showed massive fragmentation of the tank mantle. In total, 50 fragments were found. These 50 fragments make-up 88.6 % of the original tank mass. Each fragment was georeferenced and weighed. Fragment throwing distances of l > 250 m occurred. For the tanks with a fill level of 20 %, the average number of fragments was twice as high as it was for the tanks that were filled completely.
Compressed natural gas (CNG) is a widely used automotive fuel in a variety of countries. In case of a vehicle fire where the safety device also malfunctions, a failure of the CNG automotive cylinder could occur. Such a cylinder failure is associated with severe hazards for the surrounding environment. Firstly, a comprehensive analysis is given below, summarizing various accidents involving CNG automotive cylinders and their consequences. In an extensive experimental program, 21 CNG automotive cylinders with no safety device were tested. Of the 21, burst tests were carried out on 5 Type III and 5 Type IV cylinders. Furthermore, fire tests with 8 Type III and 3 Type IV cylinders were conducted. Apart from cylinder pressure, inner temperature and cylinder mantle temperature, the periphery consequences, such as nearfield blast pressure and fragmentation are documented. The maximum measured overpressure due to a Type III cylinder failure was p = 0.41 bar. Each traceable fragment was georeferenced. All-in-all, fragment throw distances of d > 300 m could be observed. As one key result, it can be stated that the tested Type IV CNG cylinders showed less critical failure behavior then the Type III cylinders under fire impingement.
In the presented work, the potential of fiber-optic distributed acoustic sensing (DAS) for detection of small gas pipeline leaks (<1%) is investigated. Helical wrapping of the sensing fiber directly around the pipeline is used to increase the system sensitivity for detection of weak leak-induced vibrations. DAS measurements are supplemented with reference accelerometer data to facilitate analysis and interpretation of recorded vibration signals. The results reveal that a DAS system using direct fiber application approach is capable of detecting pipeline natural vibrations excited by the broadband noise generated by the leaking medium. In the performed experiment, pipeline vibration modes with acceleration magnitudes down to single ug were detected. Simple leak detection approach based on spectral integration of time-averaged DAS signals in frequency domain was proposed. Potential benefits and limitations of the presented monitoring Approach were discussed with respect to its practical applicability. We demonstrated that the approached is potentially capable of detection and localization of gas pipeline leaks with leak rates down to 0.1% of the pipeline flow volume and might be of interest for monitoring of short- and medium-length gas pipelines.
For hazard assessment purposes, the dispersion of gases in complex urban areas is often a scenario to be considered. However, predicting the dispersion of heavy gases is still a challenge. In Germany, the VDI Guideline 3783, Part 1 and 2 is widely used for gas dispersion modelling. Whilst Part 1 uses a gauss model for calculating the dispersion of light or neutrally buoyant gases, Part 2 uses wind tunnel experiments to evaluate the heavier-than-air gas dispersion in generic built up areas. In practice, with this guideline, it is often not possible to adequately represent the existing obstacle configuration. To overcome this limitation, computational fluid dynamics (CFD) methods could be used. Whilst CFD models can represent obstacles in the dispersion area correctly, actual publications show that there is still further research needed to simulate the atmospheric flow and the heavy gas dispersion. This paper presents a modified k-ε-turbulence model that was developed in OpenFOAM v5.0 (England, London, The OpenFOAM Foundation Ltd Incorporated) to enhance the simulation of the atmospheric wind field and the heavy gas dispersion in built-up areas. Wind tunnel measurements for the dispersion of neutrally buoyant and heavy gases in built-up environments were used to evaluate the model. As a result, requirements for the simulation of the gas dispersion under atmospheric conditions have been identified and the model showed an overall good performance in predicting the experimental values.
CFD simulations of near-ground gas dispersion depend significantly on the accuracy of the wind field. When simulating wind fields with conventional RANS turbulence models, the velocity and turbulence profiles specified as inlet boundary conditions change rapidly in the approach flow region. As a result, when hazardous materials are released, the extent of hazardous areas is calculated based on an approach flow that differs significantly from the boundary conditions defined. To solve this problem, a turbulence model with consistent boundary conditions was developed to ensure a horizontally homogeneous approach flow. Instead of the logarithmic vertical velocity profile, a power law is used to overcome the problem that with the logarithmic profile, negative velocities would be calculated for heights within the roughness length. With this, the problem that the distance of the wall-adjacent cell midpoint has to be higher than the roughness length is solved, so that a high grid resolution can be ensured even in the near-ground region which is required to simulate
gas dispersion. The evaluation of the developed CFD model using the German guideline VDI 3783/9 and wind tunnel experiments with realistic obstacle configurations showed a good agreement between the calculated and the measured values and the ability to achieve a horizontally homogenous approach flow.
The Jack Rabbit II (JR II) chlorine field trials in 2015 and 2016 involved nine 5–20 ton releases of pressurized liquefied chlorine from a tank mounted 1 m above a broad flat desert sand surface. A model comparison study was initiated, where 17 widely-used dense-gas dispersion models were run by scientists in seven countries.
Predictions were submitted following specified formats, using specified emissions and meteorology inputs. To compare with the model predictions, sets of observations were defined for the arc-maximum 1–3 s averaged concentrations (arc max C) and for cloud widths and heights (to 20 ppm and 200 ppm contours) at distances from 0.2 to 11.0 km from the release. The initial focus is on the three field trials (1, 6, and 7) that have the highest observed concentrations and that have detailed emissions information. It is found that these models are able to satisfactorily simulate (generally within a factor of two) the observed arc max C’s and their variation with downwind distance at this flat desert site. At each downwind distance, the scatter in the arc max C predictions covers about 1 ½ orders of magnitude, but the observed arc max C is within the range of the predictions. The median of the cloud width predictions is about 50% larger than the observed value for the three trials. The median of the cloud height predictions is within about 10% of the observed value. For both cloud width and/or height, there are a few models with large (factor of 3 or higher) overpredictions. Of the 17 models, when compared to observations, there is a core group of 5 or 6 with consistently (across all three trials and all distances) less mean error and scatter in their predictions of arc max C and cloud width and height. However, as a group, the 17 models are performing adequately (using the “factor of two” rule of thumb). An important caveat is that, at the JR II desert site, chlorine deposition is minimal. At a site with vegetation and/or organic-rich soil, the effects of removal of chlorine by deposition are expected to be significant.
Industrial piping systems are particularly relevant to public safety and the continuous availability of infrastructure. However, condition monitoring systems based on many discrete sensors are generally not well-suited for widespread piping systems due to considerable installation effort, while use of distributed fibre-optic sensors would reduce this effort to a minimum. Specifically distributed acoustic sensing (DAS) is employed for detection of third-party threats and leaks in oil and gas pipelines in recent years and can in principle also be applied to industrial plants. Further possible detection routes amenable by DAS that could identify damage prior to emission of medium are subject of a current project at BAM, which aims at qualifying distributed fibre optic methods such as DAS as a means for spatially continuous monitoring of industrial piping systems. Here, first tests on a short pipe are presented, where optical fibres were applied directly to the surface. An artificial signal was used to define suitable parameters of the measurement system and compare different ways of applying the sensor.
Pipe integrity is a central concern regarding technical safety, availability, and environmental compliance of industrial plants and pipelines. A condition monitoring system that detects and localizes threats in pipes prior to occurrence of actual structural failure, e.g., leakages, especially needs to target transient events such as impacts on the pipe wall or pressure waves travelling through the medium. In the present work, it is shown that fiber-optic distributed acoustic sensing (DAS) in conjunction with a suitable application geometry of the optical fiber sensor allows to track propagating acoustic waves in the pipeline wall on a fast time-scale. Therefore, short impacts on the pipe may be localized with high fidelity. Moreover, different acoustic modes are identified, and their respective group velocities are in good agreement with theoretical predications. In another set of experiments modeling realistic damage scenarios, we demonstrate that pressure waves following explosions of different gas mixtures in pipes can be observed. Velocities are verified by local piezoelectric pressure transducers. Due to the fully distributed nature of the fiber-optic sensing system, it is possible to record accelerated motions in detail. Therefore, in addition to detection and localization of threatening events for infrastructure monitoring, DAS may provide a powerful tool to study the development of gas explosions in pipes, e.g., investigation of deflagration-to-detonation-transitions (DDT).