Guided waves are increasingly a subject of great interest in nondestructive testing. An example of research in this field is the development of a novel procedure for ultrasonic testing of wheelset-axles using guided waves, which requires to treat the wheelset-axle as a thick walled cylinder with varying thickness. In order to describe ultrasound propagation in a waveguide with non-constant thickness, a multimodal approach, which allows to avoid extensive mesh-based numerical calculations, seems to be promising. The method treats the modes of a corresponding waveguide with constant thickness as a base in which an arbitrary sound field can be expressed. Since the local sound field at any given position in the waveguide with varying thickness will be a combination of these base modes, the problem is reduced to solving the differential equation that governs the evolution of the coefficients in the mode spectrum along the waveguide. Once the description of the sound field along the waveguide is obtained, the time dependence is added by multiplication with a simple oscillating term. Simulations of pulse propagation through the waveguide can then be constructed by adding up a sufficient number of mono-frequent continuous wave solutions. As an early stage in developing a simulation tool for sound propagation in thick walled cylinders with varying thickness, the multimodal approach was implemented and tested for the simple case of plate geometries. In this work, an overview of the simulations carried out for plates with non-constant thickness is presented. The performance of the algorithm based on the multimodal approach and the obtained results are compared to those of mesh-based simulation tools.
Quantitative evaluation of ultrasonic C-scan images in homogeneous and layered anisotropic austenitic materials is of general importance for understanding the influence of anisotropy on wave fields during ultrasonic non-destructive testing and evaluation of these materials. In this contribution, a three dimensional ray tracing method is presented for evaluating ultrasonic C-scan images quantitatively in general homogeneous and layered anisotropic austenitic materials. The directivity of the ultrasonic ray source in general homogeneous columnar grained anisotropic austenitic steel material (including layback orientation) is obtained in three dimensions based on Lamb's reciprocity theorem. As a prerequisite for ray tracing model, the problem of ultrasonic ray energy reflection and transmission coefficients at an interface between (a) isotropic base material and anisotropic austenitic weld material (including layback orientation), (b) two adjacent anisotropic weld metals and (c) anisotropic weld metal and isotropic base material is solved in three dimensions. The influence of columnar grain orientation and layback orientation on ultrasonic C-scan image is quantitatively analyzed in the context of ultrasonic testing of homogeneous and layered austenitic steel materials. The presented quantitative results provide valuable information during ultrasonic characterization of homogeneous and layered anisotropic austenitic steel materials.
The synthetic aperture focusing technique (SAFT) is an imaging technique commonly used in ultrasonic inspection. In order to apply SAFT to the inspection of austenitic welds, the inhomogeneous anisotropic nature of the weld structure has to be taken into account. A suitable approach to accomplish this, is to couple the SAFT-algorithm with a ray tracing program (RT-SAFT). While SAFT-imaging of cracks in austenitic welds by use of ray tracing has been carried out before, all attempts so far were limited to longitudinal cracks which usually allows a treatment as 2-dimensional problem. In case of transverse cracks, a full 3-dimensional ray tracing is necessary in order to perform a SAFT-reconstruction. In this paper, we give an outline of our attempts to reconstruct images of transverse cracks in austenitic welds, utilizing 3-dimensional ray tracing and a layered structure model derived from an empirical model of grain orientations in welds. We present results of this RT-SAFT on experimental data taken from transverse cracks in different austenitic welds, which show that size and position of the cracks can be estimated with good accuracy, and compare them to images obtained by assuming an isotropic homogeneous medium which corresponds to the application of the classical SAFT-algorithm.
The Synthetic Aperture Focusing Technique (SAFT) is an algorithm applied in non-destructive ultrasonic testing which provides an image of flaws within a specimen. The image is reconstructed from A-scans measured at different positions. Reliable evaluation of the images obtained by the SAFT-algorithm, however, depends on the representation of the reconstructed data, which is initially given in terms of positive and negative local values only. A suitable way of processing this data for evaluation is to calculate the envelope, which can be achieved by means of the analytic signal. The extension of this concept to the multidimensional case is neither trivial nor unique and although extensive work on this subject has been carried out in the past, a correct envelope calculation in multidimensional data remains difficult since it depends on an additional condition, namely the separability of the signal. In this paper, the concept of analytic signals with single-quadrant spectra is applied to process 2-dimensional data obtained by the SAFT-algorithm. Furthermore, we present a procedure to overcome the limitations of that approach by selecting local magnitude values from a number of rotated frames after evaluating the signals separability in each frame, which is briefly validated against synthetic and experimental data.