Ultrasonic echo testing is widely used in non-destructive testing in civil engineering to investigate concrete structures, to measure thickness, and to locate and characterise built-in components or inhomogeneities. Currently, synthetic aperture focusing techniques are mostly used for imaging. These algorithms are highly developed but have some limitations. For example, it is not possible to image the lower boundary of built-in components like tendon ducts or vertical reflectors. We adopted reverse time migration for non-destructive testing in civil engineering in order to improve the imaging of complicated structures in concrete. By using the entire wavefield, including waves reflected more than once, there are fewer limitations compared to synthetic aperture focusing technique algorithms. As a drawback, the required computation is significantly higher than that for the techniques currently used. Simulations for polyamide and concrete structures showed the potential for non-destructive testing. The simulations were followed by experiments at a polyamide specimen. Here, having acquired almost noise-free measurement data to test the algorithm, we were able to determine the shape and size of boreholes with sufficient accuracy. After these successful tests, we performed experiments at a reinforced concrete foundation slab. We obtained information from the data by reverse time migration, which was not accessible by traditional imaging. The imaging of the location and structure of the lower boundary of the concrete foundation slab was improved. Furthermore, vertical reflectors inside the slab were imaged clearly, and more flaws were found. It has been shown that reverse time migration is a step forward in ultrasonic testing in civil engineering.
Die beiden in dieser Arbeit dargestellten Beispiele zeigen, dass sich die Low-strain-Pfahlintegritätsprüfung noch über den bisherigen, schon sehr erfolgreichen Stand hinaus entwickeln kann. Der Einsatz von Vibratortechnik und passender mathematischer Methoden bietet das Potential, Prüfungen auch unter bisher nicht lösbaren Randbedingungen durchzuführen. Dazu gehören sehr schlanke Pfähle und Messungen bei hohem Störpegel. Der erhöhte Mess- und Auswerteaufwand ist jedoch im Einzelfall gegenüber dem erzielbaren Erfolg abzugleichen. Apparativ müssen noch Entwicklungsarbeiten geleistet werden, um einen einfachen und zuverlässigen Einsatz in der Praxis zu ermöglichen. Die Messung mit mehreren Sensoren entlang des Pfahls kann schon heute in der Praxis eingesetzt werden. In vielen Fällen lassen sich damit auch Messungen an Pfählen im Bestand durchführen, bei denen die konventionelle Pfahlprüfung aufgrund von überlagernden Signalen aus der aufgehenden Struktur versagt.
Defect detection in concrete pile using impulse response measurements with sine sweep excitations
(2015)
For pile integrity inspection, a low cost and portable shaker was used to create the sine sweep signal for pile excitation. The impulse response function, calculated by the deconvolution of pile response from the sine sweep excitation, was proposed to identify the echoes in the piles due to the pile’s impedance changes. The proposed methodology has been evaluated and validated both numerically and experimentally. Based on the results from the simulations and experiments, it was found that the impulse response measurement with sine sweep excitation could be an effective tool to detect the echoes of the pile toe and the defects in the pile.
Low strain pile integrity testing is an established method in QA of foundation piles. The technique is very effective and well accepted for larger flaws and length determination. It is part of standards and recommendations. Challenges exist for more complicated structures (e. g. pile walls, diaphragm walls, and pile under structures) and small flaws. Interpretation is subjective in many cases. Possible solutions, e.g. the use of vibrators instead of a hammer or application of several sensors instead of one have been proposed decades ago, but not used much in practice. In several projects we are working on the extension and optimizations of these ideas, based on input from other engineering disciplines. In the frame of the project PileInspect we are working with an international consortium on the use of vibrators instead of a hand held hammer. This allows the full control of input signals as well as the use of (semi)automatic classification routines from machine diagnosis. At BAM we are using a low cost vibrator and deconvolution routines to improve the results of classical low strain testing. In another project we are working on multichannel measurements with sensor placement along the pile axis. This can be used to determine the travel direction of certain waves (downwards or upwards) to improve the interpretation of measurements on piles below constructions or pile walls. The use of ideas adapted from geophysics („vertical seismic profiling“) are helpful. Both concepts are proven by simulations results and first field tests.